Before proceeding, review the requirements in this section and the zoning example in the figures to
make sure that both switches are correctly zoned. For more information, see
on page 110.
Cabling for the intra-site configuration
After both Fibre Channel switches are correctly zoned, set up the intra-site configuration for the
Synchronous Mirroring feature or the Asynchronous Mirroring feature.
About this task
Note:
Complete all connections by using Fibre Channel cables of the correct length.
Steps
1. Determine whether you are adding equipment for the Synchronous Mirroring feature or the
Asynchronous Mirroring feature to an existing storage array environment.
•
If so, stop I/O activity from all hosts before proceeding. Go to Step
on page 125.
•
If not, this is a new storage array installation. Go to Step
Attention:
Possible hardware damage – DC-powered controller-drive trays and drive trays
have special power procedures that you
must follow beyond the procedures for AC-powered
trays. To get specific power-off and power-on procedures, see the installation guide for your
storage array.
2. Turn off the power to all storage arrays, hosts, Fibre Channel switches, and any other equipment
in the storage array environment.
3. Make sure that basic cabling between all of the controller trays or controller-drive trays and the
drive trays is complete on both storage arrays as described in this document.
4. Connect the primary host bus adapter for each host to an available port in zone 1 of switch 1.
The following figure shows the cabling that is described in Step
on page 125.
Note:
You can connect the cables to any port in the correct zone of the switch.
Hardware installation for Synchronous Mirroring and Asynchronous Mirroring | 125
Содержание StorNext QD7000
Страница 1: ...Hardware Cabling Guide StorNext QD7000 Firmware 8 40 xx xx 6 68683 01 Rev A...
Страница 7: ...Preface Hardware Cabling Guide vii...
Страница 10: ...E Series Hardware Cabling Guide December 2017 215 11792_B0 doccomments netapp com...
Страница 11: ......
Страница 90: ...One E5660 controller drive tray and one DE6600 drive tray Drive shelf or drive tray cabling 81...
Страница 106: ...One E2760 controller drive tray and one drive tray Drive shelf or drive tray cabling 97...