75
RDX 8000 User Guide
C. Appendix
1. Product specification
1.1 Physical specification
Mechanical dimension and unit height
1. Unit Height: 2U with clearance for units above and below
2. Unit Depth: Less than 12” (excluding connectors)
3. Unit Width: Fits standard 19” computer racks
4. Standalone Unit Weight, (without a disk): 6.0 kg
5. Packaged Unit Weight, (with accessory kit, without disks): 8.0 kg
6. Single Disk Weight (without plastic box): 0.170 kg
7. Single Packaged Disk Weight (with plastic box): 0.240 kg
1.2 Functional specification
Operating Temperature:
+10° – +35° C
Operating Temperature Gradient:
10°C/hour
Storage Temperature: - 30° – +60° C
Non-operating Temperature Gradient: 20° C/hour
Relative Humidity Operating:
20 – 80 % non-condensing
Relative Humidity Non-operating:
20 – 90 % non-condensing
Operating humidity Gradient: 10% r.h./hour
Non-operating Humidity Gradient
10% r.h./hour
Altitude Operating:
0 to 10,000 feet (3000 m) at 25° C ambient
Altitude Storage:
-22 – 30,000 feet
Input voltage: 100-240 VAC, 50-60 Hz
Input power, Unit standby:
0.7 W
Input power, Unit ready:
17 W
Input power, Unit read/write 1 Cartridge:
20 W
Input power, Unit read/write 8 Cartridge:
32 W
Power Supply key parameters:
• Total Output Power: 100W (with fan cooling, 80W with convection cooling)
• Output Voltage: 15 VDC
• Efficiency: >85% (Certification 80 PLUS Bronze)
• Input power <1.0 W with 10mA output load
• Hold up time >15 msec
• EMI class A
• MTBF > 250 k hours