14
Attendant Control
For more information on this applications, contact your
Quantum Rehab Provider.
The Attendant Control is laid out:
On/Off Button
Enables/disables power
Mode Button
Cycle through Drive Profiles and Seat Mode (if equipped)
Battery Condition Meter
Indicates battery charge
Actuator LEDs
Indicates actuators in use
Mode LED
Used for profile selection
Joystick
They joystick controls speed and direction in Drive mode.
Push the joystick to the right to select actuators in Seat
mode. Move the joystick forward or backward to activate
the desired actuator(s).
On/Off and Mode Jacks
Allow for remote On/Off and Mode switch installations
BASIC OPERATION INSTRUCTIONS
Thermal Rollback
The Q-Logic 3e Controller is equipped with a thermal rollback
circuit that monitors the temperature of the power chair's
motors and controller. If either exceeds the safe operating
temperature, the controller reduces the output to 20% of full
operation level. This reduces the power chair's speed and
allows a cool-down period. Once the temperature returns to
a safe level, the power chair will resume normal operation.
Battery Condition Meter
The battery condition meter is in front of the joystick on the
controller and as an LED on the Attendant Control.
Or
GREEN: ~100%–50%
YELLOW: ~49%–25%
RED: ~24%–0%