background image

 

2. Technical specifications 

 

Model Number 

 

Hot Spring 

90 

125 

150 

170 

200 

250 

300 

 
Storage capacity in litres 

 

 

90 

125 

150 

170 

200 

250 

300 

Overall diameter in mm 

 

 

550 

550 

550 

550 

550 

550 

550 

Overall including immersion heater in mm  605 

605 

605 

605 

605 

605 

605 

Overall height in mm   

 

 

977 

1202  1327  1477  1677  1977  2287 

Weight when full in kg 

 

 

120 

159 

188 

212 

246 

299 

353 

Primary flow/return connections in mm 

22 

22 

22 

22 

22 

22 

22 

Cold feed/hot draw off connections in mm  22 

22 

22 

22 

22 

22 

28 

Maximum water supply pressure in bar 

12 

12 

12 

12 

12 

12 

12 

System operating pressure (pre-set) in bar 

3  

Expansion vessel charge pressure in bar 

3  

Expansion relief valve set pressure in bar 

6     

Temperature and pressure relief valve set 

 

Lift pressure in bar 

 

 

 

Lift temperature in degrees centigrade 

90 

90 

90 

90 

90 

90 

90      

Maximum primary working pressure in bar  3 

 

Performance: 

 
Hot water generation time in minutes from  26 

36 

37 

36 

33 

35 

40 

15 to 65 degrees C for 

‘Indirect’ 

cylinder 

Hot water generation time in minutes from  52 

72 

86 

98 

108 

144 

202 

15 to 65 degrees C for 

‘Direct’

 cylinder 

Regeneration time in minutes for 70% of 

18 

25 

26 

25 

24 

25 

29 

Contents for 

‘Indirect’

 cylinder 

Regeneration time in minutes for 70% of 

27 

37 

45 

51 

63 

75 

136 

Contents for 

‘Direct’

 cylinder 

 

3. Check list 

 
Cylinder/expansion vessel assembly 90 ltr  1 

Cylinder/expansion vessel assembly 125 ltr  - 

-

 

Cylinder/expansion vessel assembly 150 ltr  - 

-

 

Cylinder/expansion vessel assembly 170 ltr  - 

-

 

Cylinder/expansion vessel assembly 200 ltr  - 

-

 

Cylinder assembly 250 ltr 

 

 

Cylinder assembly 300 ltr 

 

 

Expansion vessel 24 ltr, part No  

 

Pressure reducing valve, part No 

 

Expansion relief valve, part No 

 

T/P valve, pre fitted, part No   

 

15/22 Tundish, part No 

 

 

22mm motorised valve, part No 

 

Control/limit thermostat, part No 

 

Immersion heater pre fitted, part No   

1(2) 

1(2) 

1(2) 

1(2) 

1(2) 

1(2) 

1(2) 

Direct cylinder quantity in brackets. 

 
 
 
 

Содержание Hot Spring

Страница 1: ...Storage Capacities 90 125 150 170 200 250 and 300 Litres Hot Spring Installation User and Service Manual Domestic Hot Water Cylinder...

Страница 2: ...12 User instructions 20 13 Warranty 20 1 Introduction The Quantum Hot Spring is a high quality stainless steel domestic hot water cylinder suitable for use on unvented or open vented hot water systems...

Страница 3: ...3 Performance Hot water generation time in minutes from 26 36 37 36 33 35 40 15 to 65 degrees C for Indirect cylinder Hot water generation time in minutes from 52 72 86 98 108 144 202 15 to 65 degrees...

Страница 4: ...e is 12 bar 4 4 Taps and fittings All taps and fittings incorporated in the unvented system should have a rated operating pressure of 7 bar or above 4 5 Location The unit is designed to be floor stand...

Страница 5: ...5 Pipework connections Fig 1 KEY ITEM DESCRIPTION A TEMPERAURE AND PRESSURE RELIEF VALVE B HOT WATER C HEATING WATER RETURN D THERMOSTAT POCKET E COLD WATER F IMMERSION HEATER G HEATING WATER FLOW...

Страница 6: ...er demand before switching over on to central heating duty If an existing system is a flow share arrangement such as a Honeywell S or Y plan type system see Figs 3 and 4 they will also provide satisfa...

Страница 7: ...7 W Plan wiring layout and system schematic...

Страница 8: ...8 Fig 2 Y Plan wiring layout and system schematic...

Страница 9: ...9 Fig 3 S Plan wiring layout and system schematic Fig 4...

Страница 10: ...torage volumes up to and including 200 litres For cylinders of 250 and 300 litres capacity a separate 24 litre expansion vessel is supplied which MUST be connected into the cold water supply side betw...

Страница 11: ...VALVE SET 6 BAR 6 DISCHARGE PIPE 22mm DIA SEE SECTION 7 7 DRAIN COCK 8 IMMERSION HEATER 230v 3 Kw 50 Hz 9 COLD WATER INLET CONNECTION 22mm DIA 10 PRIMARY FLOW CONNECTION 22mm DIA 11 CONTROL THERMOSTAT...

Страница 12: ...Downward discharge at low level i e up to 100 mm above external surfaces such as car parks hard standings grassed areas etc are acceptable providing that where children play or otherwise come into co...

Страница 13: ...13 Typical discharge pipe arrangement Fig 6...

Страница 14: ...Worked example The example below is for a diameter temperature relief valve with a discharge pipe D2 having 4 No elbows and a length of 7 m from the tundish to the point of discharge From Maximum res...

Страница 15: ...mit trip is factory set at 85 C The immersion heater conforms with EEC Directive 76 889 for radio interference and complies with BS 800 1977 WARNING Never fit an immersion heater without a thermal cut...

Страница 16: ...ontact separation of at least 3 mm using 1 5mm sq flexible cable 85 deg C rubber insulated HOFR sheathed to comply with BS 6141 table 8 and must be fully earthed d The BEAB approval certification on t...

Страница 17: ...the valve seating and to prove the correct function of the discharge arrangement 9 4 Check all joints for leaks rectify as necessary 9 5 Check that the control and high limit settings for the indirect...

Страница 18: ...e PRV Check the strainer and if necessary remove any debris from in front of it Replace the cartridge 10 8 Check the charge pressure in the expansion vessel and top up as necessary The charge pressure...

Страница 19: ...ult your boiler manufacturers instructions 3 High limit thermostat has 3 Check and re set tripped 4 Motorised valve malfunction 4 Check wiring and or plumbing connections to motorised valve Intermitte...

Страница 20: ...ols supplied with the cylinder for a period of 2 years from the date of purchase provided that they have been installed for their intended use by a competent person and have not been modified in any w...

Отзывы: