11. Fault finding. 
 
Notice: Disconnect electrical supply before removing any electrical equipment cover. 

 

Fault   

 

 

Possible cause 

 

 

 

Remedy 

 
No hot water   

 

1. Mains supply off 

 

 

1. Open stopcock 

 

 

 

 

2. Strainer blocked 

 

 

2. Turn water supply off, 

 

 

 

 

 

 

 

 

 

    remove strainer and 

 

 

 

 

 

 

 

 

 

    clean. (see 10.6) 

 

 

 

 

3. Pressure reducing valve 

 

3. Re-fit correctly 

 

 

 

 

    (PRV) incorrectly fitted 

Water from hot taps is cold  1. Programmer set to heating   

1. Set programmer to call 

 

 

 

 

    only or not switched on  

 

    for hot water 

 

 

 

2. Central heating boiler 

 

2. Check boiler operation

 

 

    malfunction  

 

 

    if faulty consult your

 

 

 

 

 

 

 

    boiler manufacturers 

 

 

 

 

 

 

 

 

    instructions 

 

 

 

3. High limit thermostat has   

3. Check and re-set 

 

 

 

    tripped 

 

 

 

4. Motorised valve malfunction 

4. Check wiring and/or 

 

 

 

 

 

 

 

 

    plumbing connections 

 

 

 

 

 

 

 

 

    to motorised valve 

Intermittent water discharge  1. Expansion vessel has lost its 

1. Turn off stopcock 

 

 

 

    charge pressure 

 

 

    open a hot water tap 

 

 

 

 

 

 

 

 

    check vessel charge 

 

 

 

 

 

 

 

 

    pressure and recharge 

 

 

 

 

 

 

 

 

    to 3 bar 

Continuous water discharge  1. Pressure reducing valve (PRV) 

1. Check pressure from  

 

 

 

    working 

 

 

 

    PRV if greater than 

 

 

 

 

 

 

 

 

    3 bar replace cartridge 

 

 

 

2. Expansion relief valve not   

2. Manually lift the valve 

 

 

 

    seating correctly 

 

 

    once or twice to clear 

 

 

 

 

 

 

 

 

    any debris from the seat 

 

 

 

 

 

 

  

 

 

    otherwise replace valve 

 

 

 

 

3. Temperature and pressure   

3. Same remedy as above 

 

 

 

 

    relief valve not seating correctly 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание Hot Spring

Страница 1: ...Storage Capacities 90 125 150 170 200 250 and 300 Litres Hot Spring Installation User and Service Manual Domestic Hot Water Cylinder...

Страница 2: ...12 User instructions 20 13 Warranty 20 1 Introduction The Quantum Hot Spring is a high quality stainless steel domestic hot water cylinder suitable for use on unvented or open vented hot water systems...

Страница 3: ...3 Performance Hot water generation time in minutes from 26 36 37 36 33 35 40 15 to 65 degrees C for Indirect cylinder Hot water generation time in minutes from 52 72 86 98 108 144 202 15 to 65 degrees...

Страница 4: ...e is 12 bar 4 4 Taps and fittings All taps and fittings incorporated in the unvented system should have a rated operating pressure of 7 bar or above 4 5 Location The unit is designed to be floor stand...

Страница 5: ...5 Pipework connections Fig 1 KEY ITEM DESCRIPTION A TEMPERAURE AND PRESSURE RELIEF VALVE B HOT WATER C HEATING WATER RETURN D THERMOSTAT POCKET E COLD WATER F IMMERSION HEATER G HEATING WATER FLOW...

Страница 6: ...er demand before switching over on to central heating duty If an existing system is a flow share arrangement such as a Honeywell S or Y plan type system see Figs 3 and 4 they will also provide satisfa...

Страница 7: ...7 W Plan wiring layout and system schematic...

Страница 8: ...8 Fig 2 Y Plan wiring layout and system schematic...

Страница 9: ...9 Fig 3 S Plan wiring layout and system schematic Fig 4...

Страница 10: ...torage volumes up to and including 200 litres For cylinders of 250 and 300 litres capacity a separate 24 litre expansion vessel is supplied which MUST be connected into the cold water supply side betw...

Страница 11: ...VALVE SET 6 BAR 6 DISCHARGE PIPE 22mm DIA SEE SECTION 7 7 DRAIN COCK 8 IMMERSION HEATER 230v 3 Kw 50 Hz 9 COLD WATER INLET CONNECTION 22mm DIA 10 PRIMARY FLOW CONNECTION 22mm DIA 11 CONTROL THERMOSTAT...

Страница 12: ...Downward discharge at low level i e up to 100 mm above external surfaces such as car parks hard standings grassed areas etc are acceptable providing that where children play or otherwise come into co...

Страница 13: ...13 Typical discharge pipe arrangement Fig 6...

Страница 14: ...Worked example The example below is for a diameter temperature relief valve with a discharge pipe D2 having 4 No elbows and a length of 7 m from the tundish to the point of discharge From Maximum res...

Страница 15: ...mit trip is factory set at 85 C The immersion heater conforms with EEC Directive 76 889 for radio interference and complies with BS 800 1977 WARNING Never fit an immersion heater without a thermal cut...

Страница 16: ...ontact separation of at least 3 mm using 1 5mm sq flexible cable 85 deg C rubber insulated HOFR sheathed to comply with BS 6141 table 8 and must be fully earthed d The BEAB approval certification on t...

Страница 17: ...the valve seating and to prove the correct function of the discharge arrangement 9 4 Check all joints for leaks rectify as necessary 9 5 Check that the control and high limit settings for the indirect...

Страница 18: ...e PRV Check the strainer and if necessary remove any debris from in front of it Replace the cartridge 10 8 Check the charge pressure in the expansion vessel and top up as necessary The charge pressure...

Страница 19: ...ult your boiler manufacturers instructions 3 High limit thermostat has 3 Check and re set tripped 4 Motorised valve malfunction 4 Check wiring and or plumbing connections to motorised valve Intermitte...

Страница 20: ...ols supplied with the cylinder for a period of 2 years from the date of purchase provided that they have been installed for their intended use by a competent person and have not been modified in any w...

Отзывы: