background image

Chapter 3: F2000 Basic Operations
Use the BMC Web UI

30

Quantum F2000 User’s Guide

the page they are on. The 

User

 button provides quick access to profile 

settings and a 

Sign out

 option.

Navigation Menu

The 

Navigation Menu

 allows the user to navigate to all of the features 

available in the BMC Web UI.

Dashboard

The 

Dashboard

 displays the canister's control panel and includes 

sections that contain diagnostic information related to the current 

running conditions. You can click each section on the Dashboard to 

quickly access additional information.

Access the BMC Web UI

To access the BMC Web UI, you need to complete the following 

procedures:

Connect to the IPMI/BMC Port

Configure Laptop Network Settings for Direct Connections

 on 

page 31

Log Into the BMC Web UI

 on page 32

Connect to the IPMI/BMC Port

To connect to an IPMI/BMC Port on a canister:

1

Use an Ethernet cable to connect a notebook computer to the IPMI/

BMC port on a canister (see 

Figure 22

 on page 31).

Содержание F2000

Страница 1: ...User s Guide Quantum F2000 6 68750 01 Rev A...

Страница 2: ...ion of the law TRADEMARK STATEMENT Artico Be Certain and the Q brackets design DLT DXi DXi Accent DXi V1000 DXi V2000 DXi V4000 DXiV Series FlexTier Lattus the Q logo the Q Quantum logo Q Cloud Quantu...

Страница 3: ...torage Environment 3 Quantum Cloud Storage Platform 4 F2000 and NVMe Benefits 5 So What is NVMe 5 Lighting Fast Performance 5 Designed for the Future 5 SAS Architecture vs NVMe Architecture 6 F2000 Ha...

Страница 4: ...he BMC Web UI 28 Supported Browsers 28 BMC Web UI Overview 29 Access the BMC Web UI 30 Create Users or Update User Settings 35 Power Off a Canister System 39 Power Off Considerations 39 Power Off Proc...

Страница 5: ...Replacement 117 Required Tools 117 Interface Card Replacement Considerations 117 Remove an Interface Card 117 Install an Interface Card 127 PIB Canister Replacement 134 Required Tools 134 PIB Caniste...

Страница 6: ...Contents vi Quantum F2000 User s Guide Identify a Degraded SSD 173 Remove an SSD Assembly 175 Install an SSD Assembly 178 Glossary 183...

Страница 7: ...nt overviews Basic operations Customer replaceable unit CRU instructions Audience This manual is written for F2000 System users System administrators Field Service Engineers Prerequisites Prerequisite...

Страница 8: ...Chapter 4 F2000 Customer Replaceable Units CRUs provides removal and installation procedures for CRUs Glossary Notational Conventions This manual uses the following conventions Convention Example Use...

Страница 9: ...ft side of the system Refers to the left side as you face the component being described Product Safety Statements Quantum will not be held liable for damage arising from unauthorized use of the produc...

Страница 10: ...Preface x Quantum F2000 User s Guide...

Страница 11: ...Quantum office locations go to http www quantum com aboutus contactus index aspx Document No Document Title Document Description 6 68748 01 F2000 Release Notes Provides compatibility information known...

Страница 12: ...eck backup software and operating system support and locate manuals FAQs firmware downloads product updates and more in one convenient location Benefit today at http www quantum com serviceandsupport...

Страница 13: ...s Team for faster more precise root cause diagnosis StorageCare Guardian is simple to set up through the Internet and provides secure two way communications with Quantum s Secure Service Center Learn...

Страница 14: ...um F2000 User s Guide Worldwide End User Product Warranty For more information on the Quantum Worldwide End User Standard Limited Product Warranty http www quantum com serviceandsupport warrantyinform...

Страница 15: ...an overview of the Quantum F2000 array and its components and includes the following sections Product Overview on page 2 F2000 in a StorNext Shared Storage Environment on page 3 Quantum Cloud Storage...

Страница 16: ...cess RDMA networking technology to provide direct access between workstations and the NVMe storage devices to provide predictable ultra fast network performance Lastly both the software and hardware a...

Страница 17: ...k without the bottlenecks associated with current storage and networking technologies The result is dramatically lower and predictable latencies for anyone working in Ultra High Definition UHD and hig...

Страница 18: ...d Storage Platform is Software defined Run on bare metal in a virtual machine or in the cloud No hardware dependence Highly available With capabilities that include active active clustering failover a...

Страница 19: ...out data contention support playout to multiple digital intermediaries from a single volume or work effortlessly with uncompressed 8K content the F2000 supports all these workflows and more It does th...

Страница 20: ...PU cores have to go through a single SAS HBA for storage access which creates a central bottleneck for all I O With NVMe architecture there is no central bottleneck for I O Every CPU core can talk to...

Страница 21: ...nnectivity specifically designed for the highest performance and availability See Figure 5 for an overview of the main F2000 hardware components Figure 5 Main F2000 Components Item Component 1 Drive B...

Страница 22: ...under typical conditions Redundant Canisters The F2000 contains redundant hot swappable canisters Each canister contains Dual Xeon 6140 CPUs 2 3 GHz 18 C 140 W 4 x 32 GB ECC RDIMM DDR4 2666 MHz 128 G...

Страница 23: ...and includes the following sections Front Components on page 10 Rear Components on page 11 System LEDs on page 13 Canister Description on page 17 Chassis Description on page 18 Fan Module Description...

Страница 24: ...n Volatile Memory Express NVMe Solid State Drives SSDs The SSDs are numbered from 1 to 24 going left to right The drive slot number is printed at the bottom of the chassis below the SSD drive assembli...

Страница 25: ...ts and the same number of PCIe slots However the top canister is inverted when compared to the bottom This means that the port labeling and PCIe slot numbering is in the reverse order from left to rig...

Страница 26: ...hannel cards are shown installed in PCIe slots 1 and 2 in Figure 7 For more details about interface cards refer to Interface Card Descriptions on page 20 6 Port 1 10 GbE RJ45 7 Port 2 10 GbE RJ45 8 VG...

Страница 27: ...lable on the left side of the system and are visible with or without the Quantum bezel installed See Figure 8 for an example of the LEDs with the bezel installed Figure 8 Front Chassis LEDs Quantum Be...

Страница 28: ...op canister is inverted so the LEDs on that canister are located at the top right of the canister See Figure 9 for the locations and descriptions of the LEDs Figure 9 Rear Canister LEDs Item LED Actio...

Страница 29: ...U LED The PSU Fault led is located in the same position on PSU A and PSU B See Figure 10 for the location and description of the LED Figure 10 PSU LED Location Item LED Action 1 Power Off PSU power of...

Страница 30: ...t the top of the SSD drive carrier See Figure 11 for the locations and descriptions of each LED Figure 11 SSD LED Locations Item LED Action 1 Drive Fault LED Amber solid or blinking Degraded drive rep...

Страница 31: ...CPUs DIMMs and M 2 Boot Drives are all contained inside the canisters The redundancy of the canisters is designed so that the system can run on one canister in the event that the other canister fails...

Страница 32: ...cated at the front which houses all 24 of the data SSDs The rear of the chassis contains PSU bays and two canister bays see Figure 13 on page 18 The major system components such as the fan modules CPU...

Страница 33: ...ng for the F2000 The fan module is installed inside the canister in close proximity to the canister components to provide efficient cooling to system components An F2000 system contains 10 fan modules...

Страница 34: ...e following Fibre Channel FC or Ethernet interface card configurations 4 x 32 Gb FC Dual Port QLogic 2742 cards per system see Figure 15 2 x 100 GbE Dual Port Mellanox ConnectX 5 cards per system see...

Страница 35: ...Chapter 2 F2000 Component Overviews Interface Card Descriptions Quantum F2000 User s Guide 21 Figure 16 100 GbE Dual Port Mellanox ConnectX 5...

Страница 36: ...nister houses the PIB that extends the connection of the PSU to the midplane The PIB canister contains a PSU connector that attaches to the PIB The other end of the PIB canister contains a card edge c...

Страница 37: ...tinum certified and utilize C14 power cable receptacles See Table 1 for more PSU specifications Table 1 PSU Specifications Note The system power supply units PSUs require high line voltage 200 240 VAC...

Страница 38: ...Chapter 2 F2000 Component Overviews PSU Description 24 Quantum F2000 User s Guide Figure 18 PSU Components Item Description 1 Latch Release Lever 2 Power Receptacle 3 Fan 4 Handle 5 Connector...

Страница 39: ...the rear of the chassis for servicing see Figure 19 The rack rails contain a rack ear locking mechanism on both sides to secure the chassis in the rack during basic servicing procedures The rack ear...

Страница 40: ...SD assembly is comprised of two parts SSD and drive carrier See Figure 20 to identify the main components of the SSD assembly Figure 20 SSD Assembly Components Note See SSD LEDs on page 16 for details...

Страница 41: ...on page 28 BMC Web UI Overview on page 29 Access the BMC Web UI on page 30 Create Users or Update User Settings on page 35 Power Off a Canister System on page 39 Power On a Canister on page 43 Identif...

Страница 42: ...r access reports logs and create update new users Supported Browsers Table 2 provides information about the web browser and operating system OS support for the BMC Web UI Table 2 Web Browser and OS Su...

Страница 43: ...Figure 21 BMC Web UI Overview Quick Button Menu The Quick Buttons Menu provides active user information and functions The Messages and Warning buttons display information without having to leave the...

Страница 44: ...ns that contain diagnostic information related to the current running conditions You can click each section on the Dashboard to quickly access additional information Access the BMC Web UI To access th...

Страница 45: ...ess the Network and Sharing Center control panel To do this press the Windows key on the keyboard type view network status and devices and press Enter 2 On your notebook computer access the Network an...

Страница 46: ...on your macOS version 1 Select the Apple menu System Preferences Network and select the Ethernet connection In the Configure IPv4 drop down list select Manually 2 Enter the IP address and subnet mask...

Страница 47: ...e 23 Figure 23 BMC Web UI Login Screen 2 Log in to the BMC Web UI The default credentials are Username admin Password admin Note For instructions on how to change the default admin password and or cre...

Страница 48: ...Chapter 3 F2000 Basic Operations Use the BMC Web UI 34 Quantum F2000 User s Guide Figure 24 BMC Web UI Dashboard...

Страница 49: ...to update the default admin user credentials and create additional users To update the admin user account settings or create a new user 1 From the BMC Web UI Dashboard click Settings from the left me...

Страница 50: ...s Guide Figure 26 User Management Configuration Page 3 Do one of the following Click an existing user account card such as admin to update an existing account Click an unassigned user card to create...

Страница 51: ...Chapter 3 F2000 Basic Operations Create Users or Update User Settings Quantum F2000 User s Guide 37 Figure 27 User Management Configuration Page Example...

Страница 52: ...lows the user access to all functions within the BMC Web UI The other user privilege levels contain limitations to what functions and features can be accessed or configured KVM Access Enables remote K...

Страница 53: ...e F2000 for maintenance purposes you must power off both canisters and unplug the power cables from the PSUs Power Off Considerations If you power off the entire F2000 system both canisters be sure to...

Страница 54: ...Figure 28 Power Control Page 3 Verify that you are powering down the correct canister You can do this by identifying the specific canister listed on the screen in the Current Canister Position inform...

Страница 55: ...e any of the options under Peer canister Host is currently on section 5 Click Perform Action The system displays a dialog window with the message Are you sure to perform this operation 6 Click OK The...

Страница 56: ...ister System 42 Quantum F2000 User s Guide Figure 30 Fault LED on the Front of System and Rear of the Bottom Canister Item LED Action 1 System Fault Amber solid Fault conditions exist 2 Canister Fault...

Страница 57: ...PMI BMC port on the other canister b Repeat Step 1 on page 39 through Step 6 to power off the second canister c Disconnect the power cables from the PSUs to completely remove power from the system Pow...

Страница 58: ...gure 31 Power Control Page 3 Verify that you are powering on the correct canister You can do this by identifying the specific canister listed on the screen in the Current Canister Position information...

Страница 59: ...canister Host is currently on section 5 Click Perform Action The system displays a dialog window with the message Are you sure to perform this operation 6 Click OK The system then displays the follow...

Страница 60: ...ions Power On a Canister 46 Quantum F2000 User s Guide Figure 33 Power LED on the Front of System and Rear of the Bottom Canister Item LED Action 1 System Power Green solid Power on 2 Canister Power G...

Страница 61: ...Identify LED on the front of the chassis using the BMC Web UI To turn on the blue Identify LED 1 Access the BMC Web UI for a canister Note Refer to Access the BMC Web UI on page 30 for detailed instr...

Страница 62: ...r Identify Timeout time second s field The default time is 15 seconds 4 Select Perform Action The system displays a dialog window with the message Are you sure to perform this operation 5 Click OK 6 G...

Страница 63: ...er you can check the status of the canister sensors for information about a component failure To check the status of canister sensors 1 Access the BMC Web UI for a canister Note Refer to Access the BM...

Страница 64: ...nd DIMMs in a canister by viewing the System Inventory page To check the status of canister sensors 1 Access the BMC Web UI for a canister Note Refer to Access the BMC Web UI on page 30 for detailed i...

Страница 65: ...ic Operations Check the System Inventory of a Canister Quantum F2000 User s Guide 51 Figure 37 Sensor Inventory Information Page Block Diagram View 3 Click on a CPU or DIMM component for more details...

Страница 66: ...t Layout View to see the layout of the CPUs and DIMMs in the canister see Figure 38 on page 52 There are four DIMMs installed in each canister Populated DIMM slots are shown in green Figure 38 Sensor...

Страница 67: ...If you contact Quantum Technical Support for help they may request that you download and provide the IPMI Event Log for both F2000 canisters To access and download the IMPI Event Log 1 Access the BMC...

Страница 68: ...e following filters to filter the log data as needed Filter by Date allows you to select a start and end date for the log data Filter by type allows you to select All events or a specific type of even...

Страница 69: ...ime and logout date time to the log The Audit Log information is only viewable using the BMC Web UI and cannot be downloaded To access and view the Audit Log 1 Access the BMC Web UI for a canister Not...

Страница 70: ...inSCP or similar tool To create and download the Support Bundle 1 Use PuTTY to open an SSH connection to a canister using the canister s management IP address 2 Log in to the Quantum Cloud Storage Pla...

Страница 71: ...Interface Menu 4 Use your Down Arrow key to select Support Bundle and press Enter The system displays the Support Bundle screen see Figure 43 Figure 43 Support Bundle Screen 5 Write down the location...

Страница 72: ...management IP address for the canister top canister or bottom canister User name root Password the default password is esos This should have been changed during the installation See Figure 44 on page...

Страница 73: ...Logs Quantum F2000 User s Guide 59 Figure 45 WinSCP Screen 8 In the right pane of the WinSCP screen click the Parent directory icon to get to the root level directory folder see Figure 46 Figure 46 W...

Страница 74: ...User s Guide 10 Identify the support bundle file It will have a file name similar to esos_support_pkg xxxxxxxxxx tgz see Figure 47 Figure 47 WinSCP Support Bundle File Name 11 Right click on file name...

Страница 75: ...er 3 F2000 Basic Operations View and Download Logs Quantum F2000 User s Guide 61 Figure 48 WinSCP Download Window 12 Browse to a location on your computer to save the file and click OK to transfer the...

Страница 76: ...in the Software on page 63 Locate the System Serial Number on the Hardware The system serial number is located on a pull out tag on the front of the F2000 system on right side see Figure 49 You must r...

Страница 77: ...oud Storage Platform TUI using an SSH tool such as PuTTY To locate the system serial number in the software 1 Use PuTTY or similar tool to open an SSH connection to a canister using the canister s man...

Страница 78: ...ud Storage Platform TUI 3 Press the i key to display the Interface menu see Figure 52 on page 64 Figure 52 Interface Menu 4 Use your Down Arrow key to select Exit to Shell and press Enter A shell prom...

Страница 79: ...tum F2000 User s Guide 65 Figure 53 ipmitool fru Output Example 7 Press Shift Page Up to scroll up through the output to locate the FRU Device Description Builtin FRU Device ID 0 section 8 Locate the...

Страница 80: ...Chapter 3 F2000 Basic Operations Locate the System Serial Number 66 Quantum F2000 User s Guide Figure 54 F2000 System Serial Number Location...

Страница 81: ...ceable units CRUs in an F2000 array and includes the following sections ESD Precautions on page 68 Chassis Replacement on page 69 Fan Module Replacement on page 100 Interface Card Replacement on page...

Страница 82: ...ve parts Precautions must be taken to ensure that the system is not exposed to ESD while handling components or servicing the unit To avoid damaging these parts while performing maintenance procedures...

Страница 83: ...age 70 Required Tools You will need the following tools to complete this procedure 0 screwdriver 1 Phillips screwdriver Notebook computer CAT6A Ethernet cable Chassis Replacement Considerations Before...

Страница 84: ...e the New Chassis on page 79 5 Remove Components from the Failed Chassis and Install them into the New Chassis on page 79 6 Install the Chassis into the Rack on page 91 7 Connect the Cables to the Sys...

Страница 85: ...on how to access the BMC Web UI refer to Access the BMC Web UI on page 30 Chapter 3 F2000 Basic Operations 3 On the BMC Web UI Dashboard click Power Control in the navigation menu The BMC Web UI Power...

Страница 86: ...k OK to power off the canister The system displays the following message Performing Power Action Please wait The Fault LED on the front of the system and on the rear of the canister turns on solid amb...

Страница 87: ...om canister see Figure 58 Figure 58 IPMI BMC Port Location on the Top Canister 8 Repeat Step 2 on page 70 through Step 6 to power off the bottom canister Disconnect the Cables from the System To disco...

Страница 88: ...n PSU A and PSU B see Figure 60 Figure 60 Cable Retention Clips 3 Remove the power cables by pulling them out of the PSU receptacles Do not jerk the cables 4 Disconnect the CAT6A Ethernet cables from...

Страница 89: ...em contains 100 GbE cards disconnect the 100 GbE Copper Direct Attach cables from the Ethernet ports in PCIe slot 1 on the top canister and in PCIe slot 1 on the bottom canister see Figure 62 Label th...

Страница 90: ...this process 7 Disconnect the short CAT6A Ethernet cable that connects Port 4 on the top canister to port 4 on the bottom canister see Figure 63 Label the cable so you know how to reconnect it later i...

Страница 91: ...ve the failed chassis 1 Locate the black screws that are installed below the thumbscrews on the front of the chassis There is one screw on each side of the chassis 2 Remove screws from the Rails using...

Страница 92: ...ction see Figure 66 Figure 66 Thumbscrews on the Front of the Chassis Caution Two people are needed to lift and move the F2000 chassis Use care to avoid injury 5 Grasp the sheet metal brackets on eith...

Страница 93: ...ed surface next to the failed chassis In the next procedure you will move components from the failed chassis to the new chassis Remove Components from the Failed Chassis and Install them into the New...

Страница 94: ...Remove the PSU by pulling on the PSU handle until it is clear of the PSU bay see Figure 69 and set aside Figure 69 Removing the PSU c Repeat Step a through Step b for the second PSU 2 Remove the PIB...

Страница 95: ...he PIB canister until the card edge comes out of the midplane see Figure 70 Figure 70 Removing the PIB Canister c Pull the PIB canister clear of the chassis and set aside d Repeat Step a through Step...

Страница 96: ...e touches the midplane connector see Figure 71 Figure 71 Installing the PIB Canister c Press the PIB canister into the midplane connector d Verify that the PIB canister is seated firmly e Repeat Step...

Страница 97: ...r 4 F2000 Customer Replaceable Units CRUs Chassis Replacement Quantum F2000 User s Guide 83 b Slide the PSU into the slot until it seats properly into the chassis see Figure 72 Figure 72 Installing th...

Страница 98: ...w chassis a Release the drive assembly by pressing the latch release button on the drive carrier and lowering the drive carrier handle until it stops see Figure 73 Figure 73 Drive Carrier Handle Examp...

Страница 99: ...g the drive carrier release until the drive release engages see Figure 75 Figure 75 SSD Assembly Installation Example SSD in Slot 01 d Seat the drive by pressing the drive carrier handle into the driv...

Страница 100: ...page 85 to remove the remaining 23 SSD assemblies from the failed chassis and install them into the new chassis 6 Remove the canisters from the failed chassis and install them in the new chassis a Fr...

Страница 101: ...stomer Replaceable Units CRUs Chassis Replacement Quantum F2000 User s Guide 87 b Unlatch the bottom canister by pulling both of the handles out from the chassis Figure 78 Unlatching a Canister Bottom...

Страница 102: ...ure 79 Remove a Canister Bottom Canister Example d Install the bottom canister into the new chassis by lining up the canister with the same canister slot in the new chassis Make sure that the canister...

Страница 103: ...Chassis Replacement Quantum F2000 User s Guide 89 e Carefully slide the canister into the slot with both latch handles in the open position until the latch handles begin to engage see Figure 80 Figur...

Страница 104: ...User s Guide f Rotate the latch handles into the chassis until the are fully engaged see Figure 80 Figure 81 Latching the Canister Bottom Canister Example g Repeat Step a on page 86 through Step f to...

Страница 105: ...To install the chassis into the rack 1 Line up the chassis with the rack mounted rails and slide the chassis into the rack until the it is seated against the rack mounted rails see Figure 82 Figure 82...

Страница 106: ...m F2000 User s Guide 3 Tighten the thumbscrews by turning them clockwise until snug see Figure 83 Figure 83 Tightening the Thumbscrews 4 Further secure the chassis by installing the provided black scr...

Страница 107: ...es to Port 1 on the top canister and Port 1 on the bottom canister see Figure 85 Figure 85 Port 1 on the Top Canister and Bottom Canister 2 If the system contains 100 GbE cards connect the 100 GbE Cop...

Страница 108: ...to Port 4 on the top canister and the other side to port 4 on the bottom canister see Figure 87 Note This cable connection is for canister to canister communication and must be in place before applyin...

Страница 109: ...of a power failure The system will automatically start up about 20 seconds after power is applied It will take a few minutes for the system to completely start up Figure 88 PSU Locations at the Rear o...

Страница 110: ...2000 User s Guide Figure 89 Cable Retention Clips 7 Slide the retention clips forward until they stop near the cable connector Doing this will ensure that the retention clips function properly in the...

Страница 111: ...BMC Web UI refer to Access the BMC Web UI on page 30 Chapter 3 F2000 Basic Operations 3 On the BMC Web UI verify that the canister does not report any errors Note Refer to Check the Status of a Canis...

Страница 112: ...t Location on the Bottom Canister 6 Repeat Step 2 on page 97 through Step 3 to verify the bottom canister is functioning properly Install the Bezel To install the bezel 1 Locate the Quantum bezel that...

Страница 113: ...is Replacement Quantum F2000 User s Guide 99 2 Attach the bezel to the four mounting posts at the front of the chassis see Figure 94 Figure 94 Chassis Front View Bezel Mounting Post locations Item Des...

Страница 114: ...module see Fan Module Description on page 19 in Chapter 2 F2000 Component Overviews Required Tools You will need the following tools to complete this procedure Notebook computer Ethernet cable Fan Mo...

Страница 115: ...led fan module by viewing the Sensor Reading page in the BMC Web UI for both canisters Note For instructions on how to check the status of a canister sensor using the BMC Web UI refer to Check the Sta...

Страница 116: ...ith Top Cover Removed Showing Fan Slot Locations Remove a Fan Module To remove a failed fan module 1 Identifying the canister that contains the failed fan module a Connect the Ethernet cable to the IP...

Страница 117: ...to Identify a Failed Fan Module on page 100 for more information on how to identify a failed fan module d Do one of the following If the canister contains the failed fan module continue with Step 2 If...

Страница 118: ...Action A dialog window appears with the following question Are you sure to perform this operation 4 Click OK to power off the canister The system displays the following message Performing Power Actio...

Страница 119: ...ear of the Canister 5 Disconnect the CAT6A Ethernet cables from Port 1 on the canister that contains the failed fan see Figure 100 on page 106 Label the cables so you know how to reconnect them later...

Страница 120: ...the system contains 100 GbE cards disconnect the 100 GbE Copper Direct Attach cables from the Ethernet ports in PCIe slot 1 on the canister that contains the failed fan see Figure 101 Label the cables...

Страница 121: ...er in this process 8 Disconnect the CAT6A Ethernet cable that connects Port 4 on the top canister to port 4 on the bottom canister see Figure 102 Label the cable so you know how to reconnect it later...

Страница 122: ...103 Unlatching the Canister Bottom Canister Example Shown 11 Remove the canister by grasping the edges of the canister and pulling it clear of the chassis see Figure 104 Figure 104 Removing the Canist...

Страница 123: ...a Unlock the canister cover by pressing the two lock buttons and slide the cover towards the rear of the canister see Figure 105 Figure 105 Canister Cover Lock Button Locations b Remove the cover by l...

Страница 124: ...s Guide Figure 106 Fan Cable Connector Fan Slot 1 Example Shown 16 Lift the fan module up and out from the fan slot using the fan handles see Figure 107 on page 111 Item Description 1 Fan module conne...

Страница 125: ...n Module To install a fan module 1 Insert the new fan module in to the fan slot 2 Connect the fan module cable to the fan connector see Figure 106 on page 110 3 Install the canister cover a Align the...

Страница 126: ...canister slot Make sure that the canister is oriented correctly Note The top canister is inverted and installed with the top cover facing toward the bottom of the chassis The bottom canister is insta...

Страница 127: ...Bottom Canister Example Shown 5 Connect the short CAT6A Ethernet cable that connects Port 4 on the top canister to port 4 on the bottom canister see Figure 110 This is for canister to canister commun...

Страница 128: ...in place before applying power to the system 6 Connect the appropriate CAT6A Ethernet cables to Port 1 on the top canister and Port 1 on the bottom canister see Figure 111 Figure 111 Port 1 on the To...

Страница 129: ...the system The canister will power itself on about 20 seconds after it is connected to power Figure 113 Latching the Canister Bottom Canister Example 10 Verify the fan module is functioning properly a...

Страница 130: ...Chapter 4 F2000 Customer Replaceable Units CRUs Fan Module Replacement 116 Quantum F2000 User s Guide Figure 114 Sensor Reading Page Example Fan Sensor Normal...

Страница 131: ...ibre Channel card see Interface Card Descriptions on page 20 in Chapter 2 F2000 Component Overviews Required Tools You will need the following tools to complete this procedure 0 screwdriver 2 Phillips...

Страница 132: ...Note For instructions on how to access the BMC Web UI refer to Access the BMC Web UI on page 30 Chapter 3 F2000 Basic Operations 4 On the BMC Web UI Dashboard click Power Control in the navigation me...

Страница 133: ...rm Action A dialog window appears with the following question Are you sure to perform this operation 6 Click OK to power off the canister The system displays the following message Performing Power Act...

Страница 134: ...d Rear of the Canister 7 Disconnect the CAT6A Ethernet cables from Port 1 on the canister that contains the failed fan see Figure 118 on page 121 Label the cables so you know how to reconnect them lat...

Страница 135: ...ttom Canister 8 If the system contains 100 GbE cards disconnect the 100 GbE Copper Direct Attach cables from the Ethernet ports in PCIe slot 1 on the canister that contains the failed fan see Figure 1...

Страница 136: ...onnect the short CAT6A Ethernet cable that connects Port 4 on the top canister to port 4 on the bottom canister see Figure 120 Label the cable so you know how to reconnect it later in the process Figu...

Страница 137: ...0 User s Guide 123 Figure 121 Unlatching the Canister Bottom Canister Example Shown 13 Remove the canister by grasping the edges of the canister and pulling it clear of the chassis see Figure 122 Figu...

Страница 138: ...r cover a Unlock the canister cover by pressing the two lock buttons and slide the cover towards the rear of the canister see Figure 123 on page 124 Figure 123 Canister Cover Lock Button Locations b R...

Страница 139: ...Guide 125 Figure 124 Installing SFPs into FC Card Ports 17 Remove the PCIe bracket by carefully pulling up on the sheet metal carrier and lifting it out of the canister see Figure 125 Figure 125 Remo...

Страница 140: ...Quantum F2000 User s Guide Figure 126 PCIe Bracket with Interface Card Attached FC Card Example 19 Detach the interface card from the PCIe bracket by pulling the two components apart Figure 127 on pag...

Страница 141: ...er s Guide 127 Figure 127 Interface Card Detached from PCIe Bracket FC Card Example Install an Interface Card To install an interface card 1 Locate the new interface card either the 100 GbE card or th...

Страница 142: ...placeable Units CRUs Interface Card Replacement 128 Quantum F2000 User s Guide Figure 128 Attaching an Interface Card to the PCIe Bracket 3 Insert the PCIe bracket and Interface card into the canister...

Страница 143: ...er s Guide 129 Figure 129 Inserting PCIe Bracket 4 If you are installing an FC card install the SFPs into the FC ports see Figure 130 Figure 130 Installing SFPs into FC Card Ports 5 Install the canist...

Страница 144: ...ssis line up the canister with the empty canister slot Make sure that the canister is oriented correctly Note The bottom canister is inverted and installed with the top cover facing toward the bottom...

Страница 145: ...32 Installing the Canister Bottom Canister Example Shown 7 Connect the short CAT6A Ethernet cable that connects Port 4 on the top canister to port 4 on the bottom canister see Figure 133 Figure 133 Po...

Страница 146: ...ace before applying power to the system 8 Connect the appropriate CAT6A Ethernet cables to Port 1 on the top canister and Port 1 on the bottom canister see Figure 134 Figure 134 Port 1 on the Top Cani...

Страница 147: ...er until the are fully engaged This applies power to the canister The canister will power itself on about 20 seconds after it is connected to power Figure 136 Latching the Canister Bottom Canister Exa...

Страница 148: ...PIB Canister Replacement Considerations Remove a PIB Canister on page 135 Install a PIB Canister on page 137 Note For a description of the power interface board PIB canister component see PIB Canister...

Страница 149: ...disconnect the power cord from the PSU that is connected to the PIB a Detach the cable retention clip from the power cord see Figure 137 on page 135 Figure 137 Cable Retention Clip b Remove the power...

Страница 150: ...e PSU bay see Figure 139 Figure 139 Removing the PSU PSU A Shown in Example 3 Remove the PIB Canister a Locate the gray tab just below the location of the removed PSU b Grasp the gray tab firmly and c...

Страница 151: ...ssis PIB canister guide 2 Slowly slide the PIB Canister into the chassis until the card edge touches the midplane connector see Figure 141 Figure 141 Installing the PIB Canister 3 Press the PIB canist...

Страница 152: ...CRUs PIB Canister Replacement 138 Quantum F2000 User s Guide b Slide the PSU into the slot until it seats properly into the chassis see Figure 142 Figure 142 Installing the PSU c Plug the power cable...

Страница 153: ...placeable Units CRUs PIB Canister Replacement Quantum F2000 User s Guide 139 d Loop the retention clip around the cable and pinch it until the clip catches and locks in place see Figure 143 Figure 143...

Страница 154: ...Quantum F2000 User s Guide e Slide the retention clip forward until it stops near the cable connector Doing this will ensure that the retention clip functions properly in the event the cable is yanke...

Страница 155: ...ge 23 in Chapter 2 F2000 Component Overviews Required Tools There are no tools required for this component replacement PSU Replacement Considerations Before you begin a PSU replacement review the foll...

Страница 156: ...PSU Fault LED Location Remove a PSU To replace a PSU 1 From the rear of the chassis disconnect the power cord connected to the failed PSU a Detach the cable retention clip from the power cord see Fig...

Страница 157: ...unit 2 Remove the PSU from the chassis a Unlock the PSU by pressing down on the PSU release latch see Figure 147 Figure 147 PSU Release Latch b Remove the PSU by pulling on the PSU handle until it is...

Страница 158: ...e Figure 148 Removing the PSU Install a PSU To install a PSU 1 Install the PSU into the chassis a Orient the PSU so the PSU release latch is on top and the fan is on the bottom b Slide the PSU into th...

Страница 159: ...Loop the retention clip around the cable and pinch it until the clip catches and locks in place see Figure 150 Figure 150 Cable Retention Clips e Slide the retention clip forward until it stops near t...

Страница 160: ...Cinching Cable Retention Clip 2 Verify the PSU is functional by identifying the PSU Fault LED is no longer indicating a fault This is indicated by the PSU Fault LED illuminated green see Figure 152 F...

Страница 161: ...see Rack Rails Description on page 25 in Chapter 2 F2000 Component Overviews Required Tools You will need the following tools to complete this procedure 1 Phillips screwdriver Notebook computer Ether...

Страница 162: ...assis from the Rack on page 155 4 Remove the Old Rack Rails and Install the New Rack Rails on page 157 5 Install the Chassis into the Rack on page 163 6 Connect the Cables to the System on page 165 7...

Страница 163: ...te For instructions on how to access the BMC Web UI refer to Access the BMC Web UI on page 30 Chapter 3 F2000 Basic Operations 3 On the BMC Web UI Dashboard click Power Control in the navigation menu...

Страница 164: ...perform this operation 5 Click OK to power off the canister The system displays the following message Performing Power Action Please wait The Fault LED on the front of the system and on the rear of th...

Страница 165: ...see Figure 156 Figure 156 IPMI BMC Port Location on the Top Canister 8 Repeat Step 2 on page 148 through Step 6 on page 151 to power off the bottom canister Disconnect the Cables from the System To di...

Страница 166: ...om the power cables in PSU A and PSU B see Figure 158 Figure 158 Cable Retention Mechanism 3 Remove the power cables by pulling them out of the PSU receptacles Do not jerk the cables 4 Disconnect the...

Страница 167: ...5 If the system contains 100 GbE cards disconnect the 100 GbE Copper Direct Attach cables from the Ethernet ports in PCIe slot 1 on the top canister and in PCIe slot 1 on the bottom canister see Figur...

Страница 168: ...nect the short CAT6A Ethernet cable that connects Port 4 on the top canister to port 4 on the bottom canister see Figure 161 Label the cable so you know how to reconnect it later in the process Figure...

Страница 169: ...Rack To remove the failed chassis 1 Locate the black screws that are installed below the thumbscrews on the front of the chassis There is one screw on each side of the chassis 2 Remove screws from th...

Страница 170: ...ee Figure 164 Figure 164 Thumbscrews on the Front of the Chassis Caution Two people are needed to lift and move the F2000 chassis Use care to avoid injury 5 Grasp the sheet metal brackets on either si...

Страница 171: ...all the New Rack Rails To remove the old rack rails 1 Locate the black screws that are installed on the rear rail connections 2 Remove the screws from rails using a 1 Phillips screwdriver 3 Open the f...

Страница 172: ...r s Guide 4 Push the front rail connection out of the rack post see Figure 167 Figure 167 Rail Retracted Right Side 5 Carefully grasp the rail and open the rear latch by pulling the tab and rotating t...

Страница 173: ...aining rail 8 Locate the new rack rails and identify the right rack rail 9 Open the front and rear latches of the rack rails by pulling the tab and rotating the latch open until it is at 90 degrees or...

Страница 174: ...00 User s Guide 12 Secure the rear rail attachment to the rear rack post by rotating the rear latch until it clips over the rear rack post see Figure 170 on page 160 Figure 170 Rail Latched Right Side...

Страница 175: ...2000 Customer Replaceable Units CRUs Rack Rails Replacement Quantum F2000 User s Guide 161 14 Slide the front rail attachment to fit snugly up against the front rack post see Figure 171 Figure 171 Rai...

Страница 176: ...r s Guide 15 Secure the front rail attachment by rotating the front latch until it clips over the front rack post see Figure 172 Figure 172 Rail Latched 16 Secure the rear rail attachment to the rack...

Страница 177: ...To install the chassis into the rack 1 Line up the chassis with the rack mounted rails and slide the chassis into the rack until the it is seated against the rack mounted rails see Figure 173 Figure...

Страница 178: ...uantum F2000 User s Guide 3 Tighten the thumbscrews by turning them clockwise until snug see Figure 174 Figure 174 Tightening the Thumbscrews 4 Secure the chassis to the rack by installing the screws...

Страница 179: ...cables to Port 1 on the top canister and Port 1 on the bottom canister see Figure 176 Figure 176 Port 1 on the Top and Bottom Canisters 2 If the system contains 100 GbE cards connect the 100 GbE Coppe...

Страница 180: ...the bottom canister see Figure 178 Figure 178 Port 4 Canister to Canister Connection Note Verify that the short CAT6A Ethernet cable that connects Port 4 on the top canister to port 4 on the bottom ca...

Страница 181: ...of a power failure The system will automatically start up about 20 seconds after power is applied It will take a few minutes for the system to completely start up Figure 179 PSU Locations at the Rear...

Страница 182: ...F2000 User s Guide Figure 180 Cable Retention Clip 7 Slide the retention clips forward until they stop near the cable connector Doing this will ensure that the retention clips function properly in the...

Страница 183: ...he BMC Web UI refer to Access the BMC Web UI on page 30 Chapter 3 F2000 Basic Operations 3 In the BMC Web UI Dashboard verify that there are no failures reported Note Refer to Check the Status of a Ca...

Страница 184: ...Location on the Top Canister 6 Repeat Step 2 on page 169 through Step 4 on page 169 to verify the bottom canister is functioning properly Install the Bezel To install the bezel 1 Locate the Quantum be...

Страница 185: ...ls Replacement Quantum F2000 User s Guide 171 2 Attach the bezel to the four mounting posts at the front of the chassis see Figure 185 Figure 185 Chassis Front View Bezel Mounting Post locations Item...

Страница 186: ...SSD Assembly Description on page 26 in Chapter 2 F2000 Component Overviews Required Tools There are no tools required for this component replacement SSD Assembly Replacement Considerations Before you...

Страница 187: ...ou replace a degraded SSD with a drive of the same capacity Identify a Degraded SSD When an SSD becomes degraded in an F2000 appliance and needs to be replaced a RAS ticket is automatically generated...

Страница 188: ...ble on the front of the F2000 and are numbered 1 through 24 going from left to right see Figure 187 Figure 187 F2000 Front View with Drive Slot Numbering A degraded SSD displays either a solid or blin...

Страница 189: ...he Appliance Controller Console refer to Access the Appliance Controller Console in the Appliance Controller Documentation Center http www quantum com accdocs 2 In the Appliance Controller Console ent...

Страница 190: ...y 4 Locate the degraded drive using the drive slot location provided in the StorNext RAS ticket Confirm that the degraded drive s LEDs show the following activity Drive Fault LED is solid or blinking...

Страница 191: ...de 177 5 Release the SSD assembly by pressing the latch release button on the drive carrier and lowering the drive carrier handle until it stops see Figure 190 Figure 190 Drive Carrier Release 2 Drive...

Страница 192: ...Guide 6 Pull the drive assembly out of the drive slot using the drive carrier handle see Figure 191 Figure 191 Removing a Drive Install an SSD Assembly To install a new SSD assembly 1 Obtain the new...

Страница 193: ...lide the drive into the open drive slot using the drive carrier release until the drive release engages see Figure 192 Figure 192 Drive Installation 3 Seat the drive by pressing the drive carrier hand...

Страница 194: ...and The system identifies the new drive and attaches it It returns the following message if the drive attachment was successful After the drive is replaced and the qstorage drive attach auto command i...

Страница 195: ...ery operation Note The system may experience a minor performance impact until the recovery operation completes 6 Replace the bezel on the front of the F2000 Rebuild process started qsa_health degraded...

Страница 196: ...Chapter 4 F2000 Customer Replaceable Units CRUs SSD Assembly Replacement 182 Quantum F2000 User s Guide...

Страница 197: ...user workstation running StorNext client software or a computer directly attached to SAN storage through Fibre Channel SAN client F Fibre Channel FC A high speed communications channel used between a...

Страница 198: ...N NAS Client A type of StorNext user requiring SMB and NFS protocol access to the SAN storage NAS clients access SAN storage indirectly through a NAS gateway rather than being a direct client of the S...

Страница 199: ...ory flash to store data persistently SSDs emulate conventional hard drives and are available with the same interfaces that hard drives use Storage Area Network SAN A dedicated network of storage devic...

Страница 200: ...Glossary 186 Quantum F2000 User s Guide...

Отзывы: