Chapter 4: F2000 Customer Replaceable Units (CRUs)
Fan Module Replacement
Quantum F2000 User’s Guide
101
When a fan module fails and needs to be replaced, you need to identify
which canister contains the failed fan module and locate the fan
module within the canister.
You can identify which canister contains a failed fan module by viewing
the
Sensor Reading
page in the BMC Web UI for both canisters.
Note:
For instructions on how to check the status of a canister sensor
using the BMC Web UI, refer to
Check the Status of a Canister
Chapter 3, F2000 Basic Operations
The
Sensor Reading
page reports a
State
of
Normal
for all fans
operating properly. In the
Sensor Reading
,
Fan0_STATUS
and
Fan1_STATUS
report something other than
Normal
.
Figure 95
Sensor Reading
Page -
Example Fan Sensor
States