106
Chapter 7
Using GPIB Interface
Bus commands
The IEEE-488.1 standard defines bus commands, which are sent to the 802 with ATN
true. The following table lists bus commands supported by the generator. For more
detailed descriptions of these commands, see the IEEE-488.1 and 488.2 standards.
Remote/local operation
The 802 has complete remote/local operation as defined by the IEEE-488.1 standard. All
four remote/local states (REMS, LOCS, RWLS and LWLS) are supported.
In the remote state (REMS), the 802 is under remote control and messages are processed
as received. The generator enters the remote with lockout state (RWLS) if the controller
issues the local lockout (LLO) message to the 802. The generator enters the local state
(LOCS) when the REN line goes false or the controller issues the go to local (GTL)
message to the generator, or a front panel control is actuated.
Event Status bit Definition
OPC
Operation complete. Indicates that all operations have been completed.
RQC
Request control. Indicates that a device is requesting control. The generator will
never request control, so this bit will always be 0.
QYE
Query error. Indicates that a query request was made while the generator was in
deadlock.
DDE
Device dependent error. Indicates that the generator encountered an error exe-
cuting a command.
EXE
Execution error. Indicates that there was an error parsing a parameter.
CME
Command error. Indicates that there was an unrecognizable command.
URQ
User request. Indicates that a front panel key has been pressed or that the front
panel knob has been turned.
PON
Power on. Indicates that power has been turned off and on. This bit will always
be 0 in the generator.
Command
Description
DCL
Device clear. Clears the input buffer and output queue, and stops parsing any
commands.
SDC
Selected device clear. Same as DCL.
GTL
Go to local. Enters the local state. See “
Remote/local operation
” on page 106.
LLO
Local lockout. Enters the lockout state. See “
Remote/local operation
” on page
106.
SPE
Serial poll enable. Enables transmission of the Status Byte.
SPD
Serial poll disable. Exits the serial poll state.
Содержание 802BT
Страница 1: ...802BT 802R Video Test Generator User Guide ...
Страница 52: ...42 Chapter 2 Testing Video Displays ...
Страница 62: ...52 Chapter 3 Administrative Tasks ...
Страница 87: ...802BT 802R Video Test Generator User Guide 77 IMGE end an editing session IMGA MyImage save image as MyImage ...
Страница 118: ...108 Chapter 7 Using GPIB Interface ...
Страница 194: ...184 Chapter 10 Testing EDID ...
Страница 204: ...194 Chapter 11 Testing HDCP ...
Страница 213: ...Video Test Generator User Guide 203 A Command Reference Topics in this appendix Commands by name ...
Страница 214: ...204 Appendix A Command Reference Commands by name ...
Страница 303: ...Video Test Generator User Guide 293 Example 7 Turn audio off DPTG 3 DPGU Example 8 Turn audio on DPTG 7 DPGU ...
Страница 595: ...Video Test Generator User Guide 585 ...
Страница 608: ...598 Appendix A Command Reference Related commands YMDO UNPK PKUP VTOF FLSH Example YMDI YMODEM BATCH upload ...
Страница 611: ...Video Test Generator User Guide 601 ...
Страница 612: ...602 Appendix A Command Reference ...
Страница 613: ...802BT 802R Video Test Generator User Guide 603 B Image Reference Topics in this appendix Standard image descriptions ...
Страница 716: ...706 Appendix B Image Reference ...
Страница 744: ...734 Appendix C Error Messages ...