10.1. Selecting switching sensitivity (DIF)
It is possible to set the switching sensitivity. By setting this
val ue, you can specify how much the appliance switches the
outputs on/off below/above the set temperature.
The lower this value, the more consistent the internal room
temperature, the greater the comfort is. The switching sensitivity
does not affect the heat loss of the room (building). In case of
higher comfort requirements, the switching sensi tivity should be
chosen so as to ensure the most constant in ternal temperature.
The switching sensitivity can be set between ±0.1 °C and ±1.0
°C (in 0.1 °C increments). Except some special cases, we
recom mend setting ±0.1 °C or ±0.2 °C (factory default setting).
See
Chapter 8.
for more information about switching sensitivity.
10.2. Calibration of the temperature sensor (ADJ)
The measuring accuracy of the thermometer of the thermostat
is ±0.5 °C. The temperature displayed by the thermostat can be
modified in steps of 0.1 °C in comparison to the temperature
measured by the temperature sensor, but the modification must
not exceed ±3 °C.