background image

19

September 27, 2018

7082-153D

TREKKER INSERT

The leveling bolts are located on the sides of the appliance, 

front and rear. To access the bolts, remove the front access 

panels. Reach in and turn the bolt to the desired height to 

level the appliance

 (Figure 19.1)

.

Included in Kit:

 2 wire ties, 1 collar assembly, 1 

termination cap assembly, 1 trim ring, fasteners.

3 INCH (76mm) ALUMINUM FLEX PIPE NOT INCLUDED

Tools Needed:

 Phillips head screw driver; wire cutters; 

hole saw or jig saw.

1. 

Measure distance from floor to air vent opening in 

appliance and mark location on wall.

2. 

Use saw to cut opening in wall. Cut a 3-1/2 to 4 inch 

(89-102mm) opening on inside wall and a 4 to 4-1/2 

inch (102-114mm) opening on outside of house.

3. 

Use wire ties to secure flex pipe to collar assembly.

4. 

Slide trim ring over flex pipe and run pipe through wall.

5.  Attach flex pipe (not included) to outside termination 

cap with second wire tie.

6. 

Secure termination cap to outside surface.

7.  Secure trim ring to interior wall.

Figure 19.1

Collar

Wire Ties

Trim Ring

Termination Cap

3 inch Aluminum Flex

Pipe (not included)

Figure 19.2 - OAK Exploded View

Lower the leveling

bolts if necessary to

keep the insert level

when installing.

Figure 19.3

Bend tabs down.  Shipped

flat from the factory.

Included in Kit:

 (1) bottom, (1) trim front, (2) trim sides, (2) 

trim extensions

Tools Needed:

 Phillips head screw driver, measuring tape, 

gloves

1.  Remove contents from box and lay on protective 

surface to avoid scratching the paint.

2. 

Lay front and sides face down. Bend the tabs down 

toward the inside 

(Figure 18.3)

.

3. 

The side pieces are shipped flat. It is must easier to 

flex the sides into a bowed position before installing.

4. 

Lay the cast bottom face up. Attach the 2 sides FIRST 

and then the front piece

 (Figure 19.1 on pg. 19)

.

5. 

Turn the cast bottom right side up and attach the panel 

extensions. Note the alignment hole.

6. 

Attach the appropriate footers depending on the panels 

& trim set you are installing. The footers come in 2 

sizes, 3 and 5 inches. Discard the footers not used.

7. 

Place the assembled hearth support under the insert. 

Lower the leveling bolts if necessary to keep the insert 

level.

8. 

Open the door and attach the hearth support to the 

insert. There are 9 attachment holes 

(Figure 19.2 on 

pg. 19)

.

Appliance Set-Up

A. Leveling System

B. Outside Air Kit Instructions

C. Hearth Support

CAUTION

Never draw outside combustion air from:

• 

Wall, floor or ceiling cavity

•  Enclosed space such as an attic or garage

Содержание TREKKERI-MBK TREKKERI-CSB TREKKERI-PMH

Страница 1: ...s not followed exactly a fire could result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appl...

Страница 2: ...and Exhaust Connection 15 F Equivalent Feet of Pipe 16 G Pipe Selection Chart 16 5 Venting Systems 17 A Full Reline wit Outside Air Horizontal 17 B Full Reline with Outside Air Vertical 18 6 Applianc...

Страница 3: ...0061PS094E EPA Certification 98 17 EPA Certified Emissions 0 74 g hr LHV Tested Efficiency 83 2 HHV Tested Efficiency 77 9 EPA BTU Output 12 682 39 428 HR BTU Input 16 396 50 775 HR Vent Size 3 4 or...

Страница 4: ...ects or other reproductive harm For more information go to WWW P65Warnings ca gov G Combustible Materials Material made of or surfaced with any of the following materials Wood Compressed Paper Plant F...

Страница 5: ...cient additional support to meet this weight requirement prior to installation The weight of the appliance is 510 lbs with a full load of fuel the max weight is 557 lbs NOTICE Check building codes pri...

Страница 6: ...onsibility for and the warranty will be voided by the following actions Installation and use of any damaged appliance Modification of the appliance Installation other than as instructed by Hearth Home...

Страница 7: ...ion and copying this checklist for your file That this checklist remain visible at all times on the appliance until the installation is complete Electrical 120 VAC unswitched power provided to the app...

Страница 8: ...5mm 26 7 8 in 683mm 11 7 8 in 302mm 24 1 8 in 613mm 33 in 838mm 50 in 1270mm 34 1 2 in 876mm 45 in 1143mm 11 3 4 in 297mm 18 1 2 in 469mm Figure 8 2 Front View with Cast Panel Set 23 7 8 in 606mm 32 i...

Страница 9: ...or choice must be added to this dimension Figure 9 1 Built in Appliance Rear Vent NOTE Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY Illustrations diagrams are not drawn...

Страница 10: ...required Ember protection only If mantel depth is 10 inches or less than the height from the hearth to the bottom of the mantel is 39 3 4 inches Minimum Opening Dimensions Inches Millimeters A Height...

Страница 11: ...ALTERED TO ACCOMMODATE AN INSERT IT MUST BE RETURNED TO ITS ORIGINAL CONDITION BEFORE USE AS A SOLID FUEL BURNING FIREPLACE 250 2061 Heath Home Technologies 250 2061 5 5 in width x 2 in height NON AN...

Страница 12: ...ll height listed chimney liner must be installed from the appliance flue collar to the chimney top The liner must be securely attached to the insert flue collar and the chimney top The air flow of the...

Страница 13: ...es and protruding parts of the structure P 12 in Clearance above roof line for vertical terminations All minimum clearances are listed with an Outside Air Kit OAK installed unless otherwise noted in t...

Страница 14: ...he demands of the pellet appliance but consideration must be given to the total house demand House demand may consume the air needed for the appliance It may be necessary to add additional ventilation...

Страница 15: ...hrough the chimney Install through the warm airspace enclosed by the building envelope This helps to produce more draft especially during lighting and die down of the fire Considerations for successfu...

Страница 16: ...00 feet 1829m you may use 3 or 4 inch 76 to 102mm diameter type L or PL vent G Pipe Selection Chart The chart will help you in determining proper venting size according to the equivalent feet of pipe...

Страница 17: ...ombustion air from Wall floor or ceiling cavity Enclosed space such as an attic or garage Fire Risk Inspection of Chimney Masonry chimney must be in good condition Meets minimum standard of NFPA 211 F...

Страница 18: ...12 in 305mm min below 12 in 305mm min below NOTE In Canada this fireplace insert must be installed with a continuous chimney liner extending from the fireplace insert to the top of the chimney The ch...

Страница 19: ...veling bolts if necessary to keep the insert level when installing Figure 19 3 Bend tabs down Shipped flat from the factory Included in Kit 1 bottom 1 trim front 2 trim sides 2 trim extensions Tools N...

Страница 20: ...owered Phillips head screw driver 1 Remove contents from box being careful not to scratch or damage the cast trim pieces 2 Lay the surround set face down on protective covering to prevent scratching t...

Страница 21: ...21 3 Back of Top Surround Back of Side Surround Screws Figure 21 1 Shown with trim installed on panel set 2 PIECE LOG SET INSTALLATION 1 Place the left log as shown There are 2 indentations in the bot...

Страница 22: ...Key J Location Mounting of User Interface Shock hazard Do NOT remove grounding prong from plug Plug directly into properly grounded 3 prong receptacle Route cord away from appliance Do NOT route cord...

Страница 23: ...art Number OAK 3 Spark Arrestor Cap Roof Flashing Storm Collar Joist Shield Firestop Approved Class L or PL Pellet Vent Figure 23 1 WARNING Products of combustion generate carbon monoxide and differen...

Страница 24: ...24 September 27 2018 7082 153D TREKKER INSERT Date of Service Performed By Description of Service 8 Reference Materials A Service Maintenance Log...

Страница 25: ...25 September 27 2018 7082 153D TREKKER INSERT Date of Service Performed By Description of Service...

Страница 26: ...26 September 27 2018 7082 153D TREKKER INSERT Date of Service Performed By Description of Service...

Страница 27: ...Y Outside Air Kit OAK 3 Top Vent Adapter TPVNT 4 Surround Std Panel For Cast Trim SP MTVS CST Component Pack 7036 041 Surround Std Panel w Gold Trim SP MTVS GD Component Pack 7036 042 Trim Panel Set G...

Страница 28: ...te purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ De...

Отзывы: