TREKKER INSERT

Mobile Home Installation

You must use a Quadra-Fire Outside Air Kit for 

installation in a mobile home.

1.  An outside air inlet must be provided for the 

combustion air and must remain clear of leaves, debris, 

ice and/or snow. It must be unrestricted while the 

appliance is in use to prevent room air starvation which 

causes smoke spillage. Smoke spillage can also set off 

smoke alarms.

2.  The combustion air duct system must be made of 

metal. It must permit zero clearance to combustible 

construction and prevent material from dropping into 

the inlet or into the area beneath the dwelling and 

contain a rodent screen.

3.  The appliance must be secured to the mobile home 

structure by bolting it to the floor (using lag bolts). 

Use the same holes that secured the appliance to the 

shipping pallet.

4.  The appliance must be grounded with #8 solid copper 

grounding wire or equivalent, terminated at each end 

with an NEC approved grounding device.

5.  Refer to Clearances to Combustibles and floor 

protection requirements on page 8 for listings to 

combustibles and appropriate chimney systems.

6.  Use silicone to create an effective vapor barrier at 

the location where the chimney or other component 

penetrates to the exterior of the structure.

7. 

Follow the chimney manufacturer’s instructions when 

installing the vent system for use in a mobile home.

8.  Installation shall be in accordance with the 

Manufacturers Home & Safety Standard (HUD) CFR 

3280, Part 24.

Part Number: OAK-3

Spark Arrestor Cap

Roof Flashing 

Storm Collar 

Joist Shield/Firestop 

Approved Class L 

or PL Pellet Vent

 

Figure 23.1

WARNING

Products of combustion generate carbon monoxide 

and different fuels generate different levels.  Carbon 

monoxide

• 

Only use approved fuels in this appliance.

• 

Always keep door shut during operation. Operating 

this appliance with doors open can allow CO to leak 

into the home.

CO can kill you before you are aware it is in your home. 

At lower levels of exposure, CO causes mild effects that 

are often mistaken for the flu. These symptoms include 

headaches, dizziness, disorientation, nausea and fatigue. 

The effects of CO exposure can vary greatly from person 

to person depending on age, overall health and the 

concentration and length of exposure.

WARNING

It is critical to have a working smoke detector 

installed in the home of appliance operation.

 

•  Smoke alarms that are properly installed and 

maintained play a vital role in reducing fire deaths 

and injuries. Having a working smoke alarm reduces 

the chance of fire related injuries..

CAUTION

Never draw outside combustion air from:

• 

Wall, floor or ceiling cavity

•  Enclosed space such as an attic or garage

NEVER INSTALL IN A SLEEPING ROOM.

WARNING

CAUTION

THE STRUCTURAL INTEGRITY OF THE MOBILE 

HOME FLOOR, WALL AND CEILING/ROOF MUST BE 

MAINTAINED

Do NOT cut through:

• 

Floor joist, wall, studs or ceiling trusses.

• 

Any supporting material that would affect the 

structural integrity.

This appliance is to be connected to a factory-built 

chimney conforming to CAN/ULC-S629, Standard for 

650°C Factory-Built Chimneys.

For removal of the chimney for mobile home 

transportation, contact the proper transportation officials.

Содержание TREKKERI-MBK TREKKERI-CSB TREKKERI-PMH

Страница 1: ...s not followed exactly a fire could result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appl...

Страница 2: ...and Exhaust Connection 15 F Equivalent Feet of Pipe 16 G Pipe Selection Chart 16 5 Venting Systems 17 A Full Reline wit Outside Air Horizontal 17 B Full Reline with Outside Air Vertical 18 6 Applianc...

Страница 3: ...0061PS094E EPA Certification 98 17 EPA Certified Emissions 0 74 g hr LHV Tested Efficiency 83 2 HHV Tested Efficiency 77 9 EPA BTU Output 12 682 39 428 HR BTU Input 16 396 50 775 HR Vent Size 3 4 or...

Страница 4: ...ects or other reproductive harm For more information go to WWW P65Warnings ca gov G Combustible Materials Material made of or surfaced with any of the following materials Wood Compressed Paper Plant F...

Страница 5: ...cient additional support to meet this weight requirement prior to installation The weight of the appliance is 510 lbs with a full load of fuel the max weight is 557 lbs NOTICE Check building codes pri...

Страница 6: ...onsibility for and the warranty will be voided by the following actions Installation and use of any damaged appliance Modification of the appliance Installation other than as instructed by Hearth Home...

Страница 7: ...ion and copying this checklist for your file That this checklist remain visible at all times on the appliance until the installation is complete Electrical 120 VAC unswitched power provided to the app...

Страница 8: ...5mm 26 7 8 in 683mm 11 7 8 in 302mm 24 1 8 in 613mm 33 in 838mm 50 in 1270mm 34 1 2 in 876mm 45 in 1143mm 11 3 4 in 297mm 18 1 2 in 469mm Figure 8 2 Front View with Cast Panel Set 23 7 8 in 606mm 32 i...

Страница 9: ...or choice must be added to this dimension Figure 9 1 Built in Appliance Rear Vent NOTE Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY Illustrations diagrams are not drawn...

Страница 10: ...required Ember protection only If mantel depth is 10 inches or less than the height from the hearth to the bottom of the mantel is 39 3 4 inches Minimum Opening Dimensions Inches Millimeters A Height...

Страница 11: ...ALTERED TO ACCOMMODATE AN INSERT IT MUST BE RETURNED TO ITS ORIGINAL CONDITION BEFORE USE AS A SOLID FUEL BURNING FIREPLACE 250 2061 Heath Home Technologies 250 2061 5 5 in width x 2 in height NON AN...

Страница 12: ...ll height listed chimney liner must be installed from the appliance flue collar to the chimney top The liner must be securely attached to the insert flue collar and the chimney top The air flow of the...

Страница 13: ...es and protruding parts of the structure P 12 in Clearance above roof line for vertical terminations All minimum clearances are listed with an Outside Air Kit OAK installed unless otherwise noted in t...

Страница 14: ...he demands of the pellet appliance but consideration must be given to the total house demand House demand may consume the air needed for the appliance It may be necessary to add additional ventilation...

Страница 15: ...hrough the chimney Install through the warm airspace enclosed by the building envelope This helps to produce more draft especially during lighting and die down of the fire Considerations for successfu...

Страница 16: ...00 feet 1829m you may use 3 or 4 inch 76 to 102mm diameter type L or PL vent G Pipe Selection Chart The chart will help you in determining proper venting size according to the equivalent feet of pipe...

Страница 17: ...ombustion air from Wall floor or ceiling cavity Enclosed space such as an attic or garage Fire Risk Inspection of Chimney Masonry chimney must be in good condition Meets minimum standard of NFPA 211 F...

Страница 18: ...12 in 305mm min below 12 in 305mm min below NOTE In Canada this fireplace insert must be installed with a continuous chimney liner extending from the fireplace insert to the top of the chimney The ch...

Страница 19: ...veling bolts if necessary to keep the insert level when installing Figure 19 3 Bend tabs down Shipped flat from the factory Included in Kit 1 bottom 1 trim front 2 trim sides 2 trim extensions Tools N...

Страница 20: ...owered Phillips head screw driver 1 Remove contents from box being careful not to scratch or damage the cast trim pieces 2 Lay the surround set face down on protective covering to prevent scratching t...

Страница 21: ...21 3 Back of Top Surround Back of Side Surround Screws Figure 21 1 Shown with trim installed on panel set 2 PIECE LOG SET INSTALLATION 1 Place the left log as shown There are 2 indentations in the bot...

Страница 22: ...Key J Location Mounting of User Interface Shock hazard Do NOT remove grounding prong from plug Plug directly into properly grounded 3 prong receptacle Route cord away from appliance Do NOT route cord...

Страница 23: ...art Number OAK 3 Spark Arrestor Cap Roof Flashing Storm Collar Joist Shield Firestop Approved Class L or PL Pellet Vent Figure 23 1 WARNING Products of combustion generate carbon monoxide and differen...

Страница 24: ...24 September 27 2018 7082 153D TREKKER INSERT Date of Service Performed By Description of Service 8 Reference Materials A Service Maintenance Log...

Страница 25: ...25 September 27 2018 7082 153D TREKKER INSERT Date of Service Performed By Description of Service...

Страница 26: ...26 September 27 2018 7082 153D TREKKER INSERT Date of Service Performed By Description of Service...

Страница 27: ...Y Outside Air Kit OAK 3 Top Vent Adapter TPVNT 4 Surround Std Panel For Cast Trim SP MTVS CST Component Pack 7036 041 Surround Std Panel w Gold Trim SP MTVS GD Component Pack 7036 042 Trim Panel Set G...

Страница 28: ...te purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ De...

Отзывы: