April 18, 2018
7080-166B
23
TREKKER
Symptom
Possible Cause
Corrective Action
Large, lazy flame (orange
color) with black ash / soot
buildup on glass
Dirty appliance or venting
Clean unit including the fire pot, exhaust path, and
venting system
Poor fuel quality, high ash content.
Purge old fuel and use higher quality / or brand of fuel
Incorrect air-fuel adjustment
Adjust the trim (see trim adjustment section)
Excessive feeding
Adjust tuning per tuning instructions
Feed Motor locked on
Follow corrective action for feed motor not turning off
Excessive fuel spilling over the
fire pot and/or excessive flame
Dirty Appliance
Clean unit including the fire pot, exhaust path, and
venting system
Feed Motor locked on
Follow corrective action for feed motor not turning off
Black soot on the side of the
house
Dirty Appliance
Clean unit including the fire pot, exhaust path, and
venting system
Exhaust termination cap too close to
the structure
Extend the termination further from the structure
Excessive feeding (incorrect air-fuel
ratio)
Adjust the tuning (see tuning section)
Unit rumbles consistently
during burns
Too much fuel
Turn tuning down one number at a time
Too much air
Turn tuning setting to one; one number at a time
Note: Refer to
Tuning
section for more information,
page 11
.