August 3, 2018
7050-145L
11
SANTA FE FREESTANDING
EMBER PROTECTION:
It is necessary to install a Type I
floor protector.
Floor protector must be non-combustible material,
extending beneath appliance with a minimum of 6 inches
(152mm) in front of glass and 6 inches (152mm) to both
sides of the fuel loading door. Open the door and measure
6 inches (152mm) from the side edge of the opening in the
face of the appliance.*
See exception.
27 in.
minimum
26-1/2 in.
minimum
6 in
from the fuel door
opening
6 in
USA
15 in
6 in
FUEL DOOR OPENING
152MM
FROM FUEL DOOR
OPENING
152MM
686mm
minimum
673mm
minimum
CANADA
Must extend 51mm
beyond each side
of pipe (shaded area)
to the wall thimble.
152MM
FUEL DOOR OPENING
USA INSTALLATIONS
: A
non-combustible floor protection
is recommended extending beneath the flue pipe when
installed with horizontal venting or under the Top Vent
Adapter with vertical installation.
CANADA INSTALLATIONS
: A non-c
ombustible floor
protection
extending beneath the flue pipe
is
required
with horizontal venting or under the Top Vent Adapter with
vertical installation.
Figure 11.1
Figure 11.2
39-5/8 in.
22-3/4 in.
15 in.
32-1/4 in.
6 in.
from the fuel door
opening
USA
1006mm
578mm
381mm
819mm
152mm
(front door opening)
CANADA
Must extend 51mm
beyond each side
of pipe (shaded area)
to the wall thimble.
Figure 11.3
Figure 11.4
C. Hearth Pad Requirements (UL and ULC)
Fire Risk
Comply with all minimum clearances to
combustibles as specified.
Failure to comply may cause house fire.
WARNING