Quadra-Fire EXPLRMED-PBK Скачать руководство пользователя страница 15

December 3, 2015 

 

 

 

           7061-197I 

 

 

 

         

                  15

Explorer II Medium Wood Stove

Figure 15.2 - Floor Installation

B. Outside Air Kit Installation 

A source of air (oxygen) is necessary in order for combus-
tion to take place.  Whatever combustion air is consumed 
by the fi re must be replaced.  Air is replaced via air leakage 
around windows and under doors. In homes that have tightly 
sealed doors and windows, an outside air source is needed. 
An optional Outside Air Kit is available. 

Included in OAK-ACC: 

Termination cap, (2) wire ties, flex 
adapter, and fasteners

Items Needed for Installation (not supplied)

 • 4 inch fl ex aluminum pipe, or if using alternate material, 

then it shall be made from durable, non-combustible, 
heat resistant material up to 350

o

F.  Cut the pipe to the 

required length for your installation. 

  • Phillips head screw driver 

 • 

Silicone 

sealant

  • Drills and saws necessary for cutting holes through the 

wall or fl ooring in your home.

1.  Remove all materials from packing box.

2.  Using a #2 Phillips screw driver attach the fl ex adapter to 

the stove using 4 screws.  

Figure 15.1 & 15.2 

3

.

 

Floor & Rear Installation:

  Cut a 4 inch (102mm) hole in 

outside wall or fl oor to accommodate outside air piping.  
Use 4 inch (102mm) aluminum metal fl ex or rigid piping 
to directly connect outside air to appliance intake.  Use 
the supplied termination cap with a rodent screen.  Seal 
between the wall (or fl oor) and the pipe with silicone to 
prevent moisture penetration. 

WARNING

Fire Risk.   Asphyxiation Risk. 

Do not draw outside combustion air from:

• Wall, 

fl oor or ceiling cavity

•  Enclosed space such as an attic or garage

•  Close proximity to exhaust vents or chimneys

Fumes or odor may result

Asphyxiation Risk.

Outside air inlet must be located to prevent blockage 
from:

•  Leaves        •  Snow or ice       •  Other debris

Block may cause combustion air starvation

Smoke spillage may set off alarms or irritate sensitive individuals.

WARNING

Asphyxiation Risk.

Length of outside air supply duct shall NOT exceed the 
length of the vertical height of the exhaust fl ue.

• 

Fire will not burn properly

  Smoke spillage occurs when door is opened due to air star-

vation

WARNING

Figure 15.1 - Rear Installation

Содержание EXPLRMED-PBK

Страница 1: ...Hearth Home Technologies recommends NFI certified professionals or technicians supervised by an NFI certified professional HOT SURFACES Glass and other surfaces are hot during operation AND cool down...

Страница 2: ...Canada NOT APPROVED FOR MOBILE HOME INSTALLATIONS IN CANADA 1 Important Safety Information 3 A Appliance Certification 3 B BTU Efficiency Specifications 3 C Mobile Home Approved USA ONLY 3 D Glass Spe...

Страница 3: ...tained The appliance must be properly grounded to the frame of the mobile home with 8 copper ground wire and chimney must be listed to UL103 HT or a listed UL 1777 full length six inch 152mm diameter...

Страница 4: ...with unit Do NOT Overfire If appliance or chimney connector glows you are overfiring Any such action that may cause a fire hazard WARNING Fire Risk Hearth Home Technologies disclaims any responsibilit...

Страница 5: ...pped or sealed Attic mounted duct work and air handler joints and seams taped or sealed Basement installations should be avoided WARNING Negative pressure can cause spillage of com bustion fumes soot...

Страница 6: ...arance Chimney meets recommended height requirements 14 16 feet Roof flashing installed and sealed Terminations installed and sealed Clearances Section 3 Pg 7 Combustible materials not installed in no...

Страница 7: ...19 1 2 26 3 4 Figure 7 1 Front View Figure 7 2 Side View 12 1 4 20 1 16 7 15 16 27 28 15 16 Figure 7 2 Top View 29 3 25 7 8 22 3 16 Figure 7 4 Side View with horizontal flue 3 Dimensions and Clearance...

Страница 8: ...1397 Explorer II 10 1 2 267 6 1 2 165 20 1 4 514 6 1 2 165 7 178 17 1 4 438 55 1397 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS in inches Millimeters NOTE A C and F Dimensions are to the center of th...

Страница 9: ...ney should Install through the warm space enclosed by the build ing envelope This helps to produce more draft espe cially during lighting and die down of the fire Penetrate the highest part of the roo...

Страница 10: ...Minimum 3 ft 91cm Minimum Wall or Parapet Flat Roof E 2 10 3 Rule These are safety requirements and are not meant to assure proper flue draft This appliance is made with a 6 inch 152mm diameter chimne...

Страница 11: ...l black or 26 gauge blued steel or an approved air insulated double wall venting pipe Thimble A manufactured or site constructed device installed in combustible walls through which the chimney connect...

Страница 12: ...tside dimension frame from 2 x 2 framing lumber to fit into wall opening Inside opening of frame should be no less than 14 inch x 14 inch 356mm x 356mm Figure 12 1 4 Attach the wall spacer to the chim...

Страница 13: ...ctors must conform to each other to ensure a proper fit and seal Flue Gas Direction Crimped End Toward Appliance Secure pipe sections with a minimum of 3 screws Figure 13 2 Chimney Connector Stove Pip...

Страница 14: ...ry to install a floor protector Type I of a minimum of 3 8 inch 9 5mm thick metal clad millboard or equivalent a minimum of 16 inches 406mm in front of glass and 8 inches 203mm to both sides of the fu...

Страница 15: ...2 Phillips screw driver attach the flex adapter to the stove using 4 screws Figure 15 1 15 2 3 Floor Rear Installation Cut a 4 inch 102mm hole in outside wall or floor to accommodate outside air pipi...

Страница 16: ...lts securing blower onto outer wall of appliance 4 Place the bracket containing the snap disc and magnet under the bottom left rear corner See Owner s Manual for detailed operating instructions for th...

Страница 17: ...lips and convection chamber top 2 Phillips 2 Remove 1 bolt from each side of the flue transition and retrieve nuts attached to bolts 3 Turn flue transition to horizontal position Inspect rope gasketin...

Страница 18: ...6 inch 152mm factory built chimney conforming to CAN ULC 629M STANDARD FOR FACTORY BUILT CHIMNEYS 6 Follow the chimney and chimney connector manufacturer s instructions when installing the flue syste...

Страница 19: ...BK ACC Blower Control Box W Switch SRV7000 194 Y Component Pack 7033 051 Magnet Round SRV7000 140 Y Snap Disc Bracket Assembly 7033 036 Snap Disc 1 Convection Blower SRV230 0470 Y Speed Control Only R...

Страница 20: ...eration DO NOT DISCARD Please contact your Quadra Fire dealer with any questions or concerns For the number of your nearest Quadra Fire dealer log onto www quadrafire com CONTACT INFORMATION This prod...

Отзывы: