background image

 4 

 

 

 

 

                        7061-197I 

 

 

 

         December 3, 2015

Explorer II Medium Wood Stove

Install Guide

Getting Started

A. Design and Installation Considerations

Consideration must be given to: 

 • 

Safety

 • 

Convenience

 • 

Traffi c fl ow

 

•  Chimney and chimney connector required

It is a good idea to plan your installation on paper, using exact 
measurements for clearances and fl oor protection, before 
actually beginning the installation.  If you are not using an 
existing chimney, place the appliance where there will be a 
clear passage for a factory-built listed chimney through the 
ceiling and roof.  

We recommend that a qualifi ed building inspector and your 
insurance company representative review your plans before 
and after installation.

If this appliance is in an area where children may be near it is 
recommended that you purchase a decorative barrier to go 
in front of the appliance.  Remember to always keep children 
away while it is operating and do not let anyone operate 
this appliance unless they are familiar with these operating 
instructions.

WARNING

•  DO NOT CONNECT THIS UNIT TO A CHIMNEY 

FLUE SERVICING ANOTHER APPLIANCE.

•  DO NOT CONNECT TO ANY AIR DISTRIBUTION 

DUCT OR SYSTEM.

May allow fl ue gases to enter the house.

Asphyxiation Risk.

•  Installation and use of any damaged appliance. 

• Modifi cation of the appliance.

•  Installation other than as instructed by Hearth & Home 

Technologies.

•  Installation and/or use of any component part not approved 

by Hearth & Home Technologies.

•  Operating appliance without fully assembling all components.

•  Operating appliance without legs attached (if supplied with 

unit).

•  Do NOT Overfi re - If appliance or chimney connector glows, 

you are overfi ring.

Any such action that may cause a fi re hazard.

WARNING

Fire Risk.

Hearth & Home Technologies disclaims any 
responsibility for, and the warranty will be 
voided by, the following actions: 

Check building codes prior to installation.

•  Installation MUST comply with local, regional, state and 

national codes and regulations.

•  Consult insurance carrier, local building, fire officials or 

authorities having jurisdiction about restrictions, installation 
inspection, and permits.

CAUTION

 

NOTICE:

 HEARTH & HOME TECHNOLOGIES ASSUMES NO 

RESPONSIBILITY FOR THE IMPROPER PERFORMANCE 
OF THE APPLIANCE SYSTEM CAUSED BY:

• 

Inadequate draft due to environmental conditions

• Downdrafts

• 

Tight sealing construction of the structure

• 

Mechanical exhausting devices

• 

Overdrafting caused by excessive chimney heights

• 

Ideal performance is with height of chimney between 14-16 feet 
(4.26-4.88m) measured from the base of the appliance.

B. Fire Safety

To provide reasonable fi re safety, the following should be 
given serious consideration:

1.  Install at least one smoke detector on each fl oor  of 

your home to ensure your safety.  They should be 
located away from the heating appliance and close 
to the sleeping areas.  Follow the smoke detector 
manufacturer’s placement and installation instructions, 
and be sure to maintain regularly.  

2.  A conveniently located Class A fire extinguisher to 

contend with small fi res resulting from burning embers.

3. 

A CO detector should be installed in the room with the 
appliance.

4. 

A practiced evacuation plan, consisting of at least two 
escape routes.

5. 

A plan to deal with a chimney fi re as follows:

 

In the event of a chimney fi re:

Evacuate the house immediately

b. Notify 

fi re department.

Содержание EXPLRMED-PBK

Страница 1: ...Hearth Home Technologies recommends NFI certified professionals or technicians supervised by an NFI certified professional HOT SURFACES Glass and other surfaces are hot during operation AND cool down...

Страница 2: ...Canada NOT APPROVED FOR MOBILE HOME INSTALLATIONS IN CANADA 1 Important Safety Information 3 A Appliance Certification 3 B BTU Efficiency Specifications 3 C Mobile Home Approved USA ONLY 3 D Glass Spe...

Страница 3: ...tained The appliance must be properly grounded to the frame of the mobile home with 8 copper ground wire and chimney must be listed to UL103 HT or a listed UL 1777 full length six inch 152mm diameter...

Страница 4: ...with unit Do NOT Overfire If appliance or chimney connector glows you are overfiring Any such action that may cause a fire hazard WARNING Fire Risk Hearth Home Technologies disclaims any responsibilit...

Страница 5: ...pped or sealed Attic mounted duct work and air handler joints and seams taped or sealed Basement installations should be avoided WARNING Negative pressure can cause spillage of com bustion fumes soot...

Страница 6: ...arance Chimney meets recommended height requirements 14 16 feet Roof flashing installed and sealed Terminations installed and sealed Clearances Section 3 Pg 7 Combustible materials not installed in no...

Страница 7: ...19 1 2 26 3 4 Figure 7 1 Front View Figure 7 2 Side View 12 1 4 20 1 16 7 15 16 27 28 15 16 Figure 7 2 Top View 29 3 25 7 8 22 3 16 Figure 7 4 Side View with horizontal flue 3 Dimensions and Clearance...

Страница 8: ...1397 Explorer II 10 1 2 267 6 1 2 165 20 1 4 514 6 1 2 165 7 178 17 1 4 438 55 1397 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS in inches Millimeters NOTE A C and F Dimensions are to the center of th...

Страница 9: ...ney should Install through the warm space enclosed by the build ing envelope This helps to produce more draft espe cially during lighting and die down of the fire Penetrate the highest part of the roo...

Страница 10: ...Minimum 3 ft 91cm Minimum Wall or Parapet Flat Roof E 2 10 3 Rule These are safety requirements and are not meant to assure proper flue draft This appliance is made with a 6 inch 152mm diameter chimne...

Страница 11: ...l black or 26 gauge blued steel or an approved air insulated double wall venting pipe Thimble A manufactured or site constructed device installed in combustible walls through which the chimney connect...

Страница 12: ...tside dimension frame from 2 x 2 framing lumber to fit into wall opening Inside opening of frame should be no less than 14 inch x 14 inch 356mm x 356mm Figure 12 1 4 Attach the wall spacer to the chim...

Страница 13: ...ctors must conform to each other to ensure a proper fit and seal Flue Gas Direction Crimped End Toward Appliance Secure pipe sections with a minimum of 3 screws Figure 13 2 Chimney Connector Stove Pip...

Страница 14: ...ry to install a floor protector Type I of a minimum of 3 8 inch 9 5mm thick metal clad millboard or equivalent a minimum of 16 inches 406mm in front of glass and 8 inches 203mm to both sides of the fu...

Страница 15: ...2 Phillips screw driver attach the flex adapter to the stove using 4 screws Figure 15 1 15 2 3 Floor Rear Installation Cut a 4 inch 102mm hole in outside wall or floor to accommodate outside air pipi...

Страница 16: ...lts securing blower onto outer wall of appliance 4 Place the bracket containing the snap disc and magnet under the bottom left rear corner See Owner s Manual for detailed operating instructions for th...

Страница 17: ...lips and convection chamber top 2 Phillips 2 Remove 1 bolt from each side of the flue transition and retrieve nuts attached to bolts 3 Turn flue transition to horizontal position Inspect rope gasketin...

Страница 18: ...6 inch 152mm factory built chimney conforming to CAN ULC 629M STANDARD FOR FACTORY BUILT CHIMNEYS 6 Follow the chimney and chimney connector manufacturer s instructions when installing the flue syste...

Страница 19: ...BK ACC Blower Control Box W Switch SRV7000 194 Y Component Pack 7033 051 Magnet Round SRV7000 140 Y Snap Disc Bracket Assembly 7033 036 Snap Disc 1 Convection Blower SRV230 0470 Y Speed Control Only R...

Страница 20: ...eration DO NOT DISCARD Please contact your Quadra Fire dealer with any questions or concerns For the number of your nearest Quadra Fire dealer log onto www quadrafire com CONTACT INFORMATION This prod...