background image

R

October 24, 2011

Page  27

Castile & Santa Fe CE Pellet Stove 

7068-112B

We strongly recommend a minimum of 

1.5m vertical, however above the eave is 

preferred. 

Both  installations  are  approved  for  mobile  home 

installations.  Must use 76mm to 102mm “L” or “PL” 

Listed pellet venting or Listed double wall pipe and 

Quadra-Fire Outside Air Kit  in mobile homes.  Single 

wall pipe is approved for residential installations only.

Air Clearance to Pipe

:

This  appliance  was  tested  with  standard  76mm 

Listed pellet clearance pipe to combustibles.
Pellet pipe manufactures Listed reduce clearance 

pipe may be use for reduce clearance from 76mm 

air clearance to no less than 25mm air clearance to 

combustibles for approved Listed pellet pipe. 
Follow stove pipe manufactures listed air clearances 

to combustibles and installation instructions for all 

reduced air clearances installations.

The stove must be connected to a flue pipe 

conforming  to  current  standards  UNI  7129-7131 

9615.

D.  Vertical into Existing Chimney

 

 (SHOWN ON A SANTA FE)

C. Through The Wall & Vertical - External

 

 (SHOWN ON A SANTA FE)

Firestop

Flashing

Rain Cap

152mm 

Minimum

Non-combustible Hearth Pad

76mm

 

Minimum

Cleanout Cover

305mm

 

Minimum

Ceiling Support

152mm)Flue 

Connector

 Connector Adapter

76mm-152mm

Top Vent Kit

 

Non-combustible Hearth Pad

Clean-out Cover

Tee

Wall Thimble 

Support 

Bracket

every 1.5m

610mm 

Minimum

Rain Cap 

Flashing 

51mm minimum

152mm

Minimum

Figure 28.3

Figure 28.2

Firestop

Flashing

Rain Cap

152mm 

Min.

Non-combustible Hearth Pad

76mm

 

Min.

305mm

 

Minimum

76mm-76mm) 

Top Vent Kit

Clean-out Cover 

on other side

B. Vertical - Interior - Typical Installation

 

 (SHOWN ON A SANTA FE)

Figure 28.1

PREFERRED METHOD #1

PREFERRED METHOD #2

Содержание CASTILE-CE-MBK

Страница 1: ...esponsible for use and operation Read understand and follow these instruc tions for safe installa tion and operation DO NOT DISCARD WARNING Hot glass will cause burns Do not touch glass until it is co...

Страница 2: ...voeding 470 W Rated Voltage Tension nominale Nominale spanning 230 V 50 Hz Safety clearance distance back Distance de d gagement de s curit retour Veiligheidsafstand afstand terug 50 mm Safety clearan...

Страница 3: ...lame Height Adjustment Feed Rate 10 J Ignition Cycles 10 K Clear Space 10 Section 3 Maintaining Servicing Appliance A Proper Shutdown Procedures 11 B Quick Reference Maintenance Chart 11 C General Mai...

Страница 4: ...Page 4 October 24 2011 Castile Santa Fe CE Pellet Stove R 7068 112B...

Страница 5: ...R October 24 2011 Page 5 Castile Santa Fe CE Pellet Stove 7068 112B...

Страница 6: ...Overfire Install any component not approved by Hearth Home Technologies Install parts or components not Listed or approved Improper installation adjustment alteration service or maintenance can cause...

Страница 7: ...E children in same room as appliance Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and...

Страница 8: ...ppliance robbing heat from your home Damp pellet fuel can clog the feed system Size Pellets are either 6 or 8mm in diameter Length should be no more that 38mm Pellet lengths can vary from lot to lot f...

Страница 9: ...our appliance will automatically light and deliver heat When the room is up to temperature and the thermostat is satisfied the red call light will go off and the appliance will shut down 2 Heat Output...

Страница 10: ...minutes This blower transfers heat from your appliance into the room and will continue to run after the thermostat has stopped calling for heat until the appliance has cooled down 3 Occasionally the a...

Страница 11: ...build up OR X Ash Removal from Firebox Every 5 bags or more frequently depending on the fuel type or ash build up OR X Beneath Heat Exchanger Every 1 ton of fuel OR X Blower Combustion Exhaust More f...

Страница 12: ...ust blower and vent system b Plug in your appliance if unplugged and turn the thermostat on and immediatley shut it off to start the exhaust blower on its cycle time It will pull fly ash out the exhau...

Страница 13: ...d close cast hinge face 10 Cleaning the Hopper Frequency Monthly or after burning 50 bags of fuel By Homeowner After burning approximately 1 ton of fuel you will need to clean the hopper to prevent sa...

Страница 14: ...e Technician Task Contact your local dealer 14 Cleaning Convection Blower Requires No Lubrication Frequency Yearly or every 25 bags or more fre quently depending on operating environ ment By Qualified...

Страница 15: ...and possible hopper fires Poor quality pellet fuel or lack of maintenance can create conditions that make the firepot fill quickly with ashes and clinkers This condition makes the appliance susceptib...

Страница 16: ...oot 3 Excessive build up of ash See solution 4 The lower burn settings will produce more ash the higher burn settings produce less The more it burns on low the more frequent cleaning of the glass is r...

Страница 17: ...affect the loca tion of the vent termination Marginal Location Below peak Location NOT recommended Not the highest point of the roof Wind loading possible Multi level Roofs Windward Leeward Recommende...

Страница 18: ...dealer any parts damaged in shipment All labels have been removed from the glass door Plated surfaces have been wiped clean with a soft cloth if applicable Read all the instructions before starting th...

Страница 19: ...ew Figure 20 1 Top View Figure 20 3 Side View Figure 20 4 Side View with Top Vent Adapter 658mm 324mm 540mm 729mm 426mm 715mm 653mm 95mm 64mm 73mm 683mm 609mm 626mm 305mm 609mm 725mm 405mm 582mm 431mm...

Страница 20: ...Appliance 50 H Side Wall to Flue Pipe 76 Alcove Installation Millimeters Minimum Alcove Height 1092 Minimum Alcove Side Wall 152 Minimum Alcove Width 965 Maximum Alcove Depth 914 Dimension to Corner M...

Страница 21: ...tion Figure 22 3 Figure 22 4 Must extend 51mm beyond each side of pipe shaded area C Hearth Pad Requirements If the current flooring is made from wood provide adequate surface protection according to...

Страница 22: ...service shall be the same as minimum clearance to vinyl soffits Clearance of a termination cap above electrical service will be 305mm minimum Location of the vent termination must not obstruct or inte...

Страница 23: ...erformance of the chimney system caused by Inadequate draft due to environmental conditions Downdrafts Tight sealing construction of the structure Mechanical exhausting devices D Draft To minimize the...

Страница 24: ...with at least 3 screws through each joint 5 DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT 6 DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE NOTE All pipe...

Страница 25: ...foot Hearth Home Technologies recommends any installation requiring more than two 90 elbows or more than 4 5m of venting to use 102mm vent NOTICE These are guidelines for successful venting of your pe...

Страница 26: ...and are FOR DESIGN PURPOSES ONLY Illustrations diagrams are not drawn to scale Actual installation may vary due to individual design preference A Alcove Figure 27 1 All minimums listed are to a combus...

Страница 27: ...actures listed air clearances to combustibles and installation instructions for all reduced air clearances installations The stove must be connected to a flue pipe conforming to current standards UNI...

Страница 28: ...FE Non combustible Hearth Pad Airtight Cleanout Door Cleanout cover Sheathing 76mm Minimum 25mm Clearance Flashing Fireclay flue Liner with Airspace Concrete Cap 25mm Clearance with Firestop 152mm Mi...

Страница 29: ...e Horizontal Termination Cap 51mm Minimum 152mm Minimum From Glass NOTICE Please note that while the minimum clearance for the termination cap is 152mm there is the possibility of soot build up around...

Страница 30: ...e saw to cut opening in wall Cut a 64 to 76mm open ing on inside wall and a 76 to 89mm opening on outside of house 2 Remove cover plate and then install the collar assembly 3 Use hose clamp to secure...

Страница 31: ...tional programmable thermo stat or remote control It is equipped with an adjustable heat anticipator The current rating is 05 amps The anticipator needs to be adjusted to the lowest setting available...

Страница 32: ...instruc tions included Leave this manual with party responsible for use and operation Read understand and follow these instruc tions for safe installa tion and operation DO NOT DISCARD Date purchased...

Отзывы: