background image

5. Firebrick

Your appliance is lined with high quality firebrick and 

refractory board, which has exceptional insulating proper-

ties. 
Do not operate the appliance without bricks and refractory 

board in place. Make sure bricks are installed as shown in 

Figure 3.3.
Do not use a grate; simply build a fire on the firebox floor.

22 x 8

20.44 x 14.5

Figure 3.3

9

Quadra-Fire • Adventure-III Owner’s Manual • 4083-900 • Rev D • 09/15

Содержание Adventure-II

Страница 1: ... injury or death WARNING HOT SURFACES Glass and other surfaces are hot during operation AND cool down Hot glass will cause burns DO NOT touch glass until it is cooled NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as appliance Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable material...

Страница 2: ...tenance Log 26 B Service Parts Accessories 27 C Contact Information 32 1 Welcome A Congratulations 3 B LIMITED LIFETIME WARRANTY 4 2 Product Specific Information A Appliance Certification 6 B BTU Efficiency Specifications 6 C Manufactured Housing Approved 6 D Glass Specifications 6 3 Important Safety and Operating Information A Fire Safety 7 1 Clear Space 7 2 Over Firing Your Appliance 7 3 Chimney...

Страница 3: ...mps 60 Hz Route power cord away from unit Do not route cord under or in front of appliance DANGER Risk of electrical shock Disconnect power supply before servicing Replace glass only with 5mm ceramic available from your dealer Do not use grate or elevate fire Build wood fire directly on hearth Do not overfire if heater or chimney connector glows you are overfiring OPERATE ONLY WITH DOORS CLOSED Op...

Страница 4: ... on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The warranty period for parts and labor for covered components is produced in the ...

Страница 5: ...s a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enameled surfaces caused by fingerprints accidents misuse scratches melted items or other external sources and residues left on the plated surfaces from the use of abrasive cleaners or polishes Rep...

Страница 6: ... connector glows you are overfiring Any such action that may cause a fire hazard A Appliance Certification NOTE Hearth Home Technologies manufacturer of this appliance reserves the right to alter its products their specifications and or price without notice NOTE This installation must conform with local codes In the absence of local codes you must comply with the UL1482 UM 84 HUD and NPFA211 in th...

Страница 7: ...le materials gasoline and other flammable vapors and liquids clear of the appliance Do NOT store flammable materials close to the appliance use gasoline lantern fuel kerosene charcoal lighter fluid or similar liquids to start or freshen up a fire in this appliance 2 Over Firing Your Appliance WARNING Risk of Fire Do not over fire Symptoms of over firing may include one or more of the following chi...

Страница 8: ...n cause a structure fire Ceramic Blanket and Baffle Board are NOT in contact with the back of the firebox Ceramic Blanket is NOT in contact with the back of the firebox and NOT even with the Baffle Board in the front Ceramic Blanket is bunched up at the back of the firebox and NOT even with the Baffle Board in the front Ceramic Blanket Back of Firebox Baffle Board INCORRECT POSITIONS WARNING Fire ...

Страница 9: ...l insulating proper ties Do not operate the appliance without bricks and refractory board in place Make sure bricks are installed as shown in Figure 3 3 Do not use a grate simply build a fire on the firebox floor 22 x 8 20 44 x 14 5 Figure 3 3 9 Quadra Fire Adventure III Owner s Manual 4083 900 Rev D 09 15 ...

Страница 10: ...lothing furniture draperies and other flammable materials away HOT SURFACES Glass and other surfaces are hot during operation AND cool down Figure 3 4 General Operating Parts 5 Fan Speed Control optional Operating Instruction Label Wiring Diagram Label Control Board Cover lift to remove 4 Battery Holder lift out Discard if optional fan installed Fan optional Thermostat Terminal Block Pedestal Scre...

Страница 11: ...s calling for heat then the light stays green for as long as the appliance is burning on high No Light The appliance will progress into a shutdown phase and slowly cool down and the light will turn off Every thing is working OK but the SBT button will need to be pushed when reloading fuel Red Light When the thermostat calls for heat while the appliance is in charcoal phase the air control will ope...

Страница 12: ...unwanted time periods except Wake Saturday and Sunday can be programmed individu ally by changing the format from 5 2 to 5 1 1 To change the format 1 Press and hold the up button and the center button until the display changes 2 Press up or down to change system function num ber to 16 3 Press NEXT to advance to next function 4 Press up or down to change status number to 1 5 Press DONE to exit and ...

Страница 13: ... Materials containing asbestos 7 Construction or demolition debris 8 Railroad ties or pressure treated wood 9 Manure or animal remains However if at all possible the best arrangement is to have a mix of softwood and hardwood This way you can use the softwood for starting the fire giving off quick heat to bring the appliance up to operating tem perature Add the hardwood for slow even heat and longe...

Страница 14: ...as high a moisture content now as it did when it was cut To season wood Cut logs to size Split to 6 in 152 mm or less Air dry to a moisture content of around 20 Soft wood about nine months Hard wood about eighteen months Notice Seasoning time may vary depending on drying conditions 4 Storing Wood Splitting wood before it is stored reduces drying time The following guideline will ensure properly se...

Страница 15: ...at least annually be fore lighting or once every two months during heating season When creosote has accumulated it should be removed to reduce the risk of a chimney fire D Building a Fire 1 First Fire Before lighting your first fire make certain that the baffle and ceramic blanket are correctly positioned resting against the rear support the baffle protector channel is in position firebricks are i...

Страница 16: ... second Left thermocouple error call your dealer 3 fast red blinks then no color for 1 second Right thermocouple error call your dealer 1 red blink every 1 2 second continually Overfire indication do not load fuel Call your dealer LED Operation WARNING RISK OF FIRE Close and securely latch the door after the fire has started and after refueling to prevent Spillage of smoke flame and carbon monoxid...

Страница 17: ...utton on the thermostat to start the programmed event 3 Lighting the Fire 1 Set the thermostat to the desired temperature 2 Push the SBT button the air control will open and the light should illuminate green 3 Place 2 small logs 6 in diameter or less in the firebox one on each side 4 Place several wads of crushed paper on the firebox floor 5 Lay small sticks of kindling on top of the paper in a cr...

Страница 18: ...n illness or possible death Fire Risk Keep combustible materials gasoline and other flammable vapors and liquids clear of appliance WARNING Do NOT store flammable materials in the appliance s vicinity DO NOT USE GASOLINE LANTERN FUEL KEROSENE CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS TO START OR FRESHEN UP A FIRE IN THIS HEATER Keep all such liquids well away from the heater while it is in use Com...

Страница 19: ...till pull it out replace the door gasket Check the glass frame for loose screws to prevent air leakage Check glass for cracks WEEKLY or After Every 25 Loads of Wood Check the door latch for proper adjustment This is very important especially after the door rope has formed to the appliance face Check door handle for smooth cam operation Task Blanket Baffle Ashes must be cool before you can dispose ...

Страница 20: ...imney once every two months during heating season Remove creosote to reduce risk of chimney fire Ignited creosote is extremely HOT Fire Risk Disposal of Ashes WARNING Ashes should be placed in metal container with tight fitting lid Do not place metal container on combustible surface Ashes should be retained in closed container until all cinders have thoroughly cooled 2 Disposal of Ashes Frequency ...

Страница 21: ...ure Competition with exhaust devices Do not use exhaust fans during start up Open window below the appliance towards the wind Activation button not pressed when starting fire Press activation button and ensure that the indicator light turns solid green Actuator on air control did not move to full open position In all cases the air control will move to the full open position after pressing the acti...

Страница 22: ...o the field diagnostics to perform some testing Thermocouples in appliance are no longer in proper position The theromocouples that sense the condition of the fire in the appliance must be in the proper location A hit from loading fuel or other event may have caused them to bend excessivly In a cool appliance they can be bent back into proper postion Thermocouple failure This will be indicated by ...

Страница 23: ...shutdown too quickly or too much heat when commanded to shutdown Three fast blinks of red light then long off 1 sec Right Thermocouple burned out open circuit Appliance will exhibit either late or premature shutdowns Could lead to snuffing of the fire if shutdown too quickly or too much heat when commanded to shutdown 5 second on and 5 off of red light Overfire Indication The appliance air control...

Страница 24: ... glass Avoid striking scratching or slamming glass Do NOT clean glass when hot Do NOT use abrasive cleaners Use a hard water deposit glass cleaner on white film Refer to maintenance instructions CAUTION 6 Service Part Replacement B Door Handle Assembly 1 Slide door handle through door 2 Install washer s as shown in Figure 6 1 3 Install key in groove 4 Align groove in latch cam with key slide latch...

Страница 25: ...ved the guards will come down 8 Next you will need to remove 2 screws from the side panel of the appliance for the thermocouple that you are replacing The screws are found on the back side of the appliance 9 Once you remove the screws pull the shield out and remove 10 The thermocouple will be on the top front portion of the firebox side You will need to remove two 3 8 self tap ping hex head screws...

Страница 26: ...Date of Service Performed By Description of Service A Service Maintenance Log 7 Reference Materials 26 Quadra Fire Adventure III Owner s Manual 4083 900 Rev D 09 15 ...

Страница 27: ... Baf e Blanket SRV4083 205 4 Baf e Qty 2 req SRV4083 113 5 Thermocouple Qty 2 req SRV4083 147 6 Sensor Shield 2 pcs SRV4083 212 Door Assembly See Following Pages Manifold Tube Set TUBES 4083 Y 7 Manifold Tube Front SRV4083 139 Y 8 Manifold Tube Middle SRV4083 206 Y 9 Manifold Tube Back Qty 3 req SRV4083 138 Y 10 Brick Retainer Side Qty 2 req SRV4083 121 11 Brick Retainer Back SRV4083 123 12 Pedest...

Страница 28: ... 12 Pedestal Assembly SRV4083 017 12 1 Control Plate Assembly SRV4083 035 12 2 Battery Backup SRV4083 177 Y 12 3 Pedestal Catch Bracket SRV4083 197 12 4 Pedestal Door Assembly SRV4083 033 12 5 Door Handle 7033 274 Twin Ball Catch SRV7000 532 12 6 Control Board Cover SRV4083 034 12 7 Control Board Assembly SRV4083 050 Y 12 8 Push Button SRV4083 134 Y 12 9 Pedestal Screen SRV4083 183 12 10 Pedestal ...

Страница 29: ...q SRV4083 202 16 3 Brick 9 15 16 x 4 1 2 x 1 1 4 Qty 6 req SRV4083 208 16 4 Brick 13 1 4 x 4 1 2 x 1 1 4 Qty 14 req SRV7000 306 17 Refractory Assembly SRV4083 026 17 1 Refractory Bottom Qty 3 req SRV4083 135 17 2 Refractory Side Qty 2 req SRV4083 136 18 1 Air Control Channel Assembly SRV4083 012 18 2 Air Control Channel Gasket SRV4083 189 18 3 Linear Actuator SRV4083 130 18 4 Detent Pin 5 32 Qty 2...

Страница 30: ...e Pins 1 2 Qty 2 Gold 832 0250 Qty 2 Nickel 430 5320 19 2 Rope Door 3 4 x 84 Field cut to Size 7 Ft Length 832 1680 Y 19 3 Door Glass Assembly 17 5 8 W x 11 1 2 H 7000 014 Y Gasket Glass Tape Field cut to Size 5 Ft Length 832 0460 Y Screw Flat Head Philips 8 32 x 1 2 Pkg of 10 832 0860 Y 19 4 Glass Frame Set Qty 4 Pc GLA FRM 5700 20 Door Handle Assembly SRV7033 071 Cam Latch 430 1141 Key Cam Latch...

Страница 31: ... Wire Harness AC SRV4083 176 Y Wire Harness Blower AC SRV4083 178 Y Manifold Clip Screw 832 0661 Component Pack SRV4083 030 Power Cord 812 1180 Y Wire Harness TSTAT Block SRV7080 152 Y Thermostat Programmable WALL STAT P Y Wire Harness T STAT Wire 230 0810 Y Accessories Blower Kit BK 350 Fan SRV4083 300 Fan Control SRV4083 179 Knob Knurled Black SRV4083 743 Outside Air Kit OAK ADV FASTENERS Bolt H...

Страница 32: ...roduct may be covered by one or more of the following patents United States 5341794 5263471 6688302 7216645 7047962 or other U S and foreign patents pending DO NOT DISCARD THIS MANUAL CAUTION Important operating and maintenance instruc tions included Leave this manual with party responsible for use and operation Read understand and follow these instruc tions for safe installa tion and operation DO...

Отзывы: