5100-I WOOD INSERT
Page 18
January 30, 2004
R
250-1960 Rev B
BURN RATES
STARTING FIRE
: Open both controls (push in) completely. After a wood load has been burning on high for 5 to 15 minutes or longer for
very large pieces, close the Start-Up Air Control (right side) by pulling it out.
HIGH:
Leave the Primary Air Control fully open (under ashcatcher). It is especially important to fully open both controls when reloading
the insert as failure to do so could result in excessive emissions, also referred to as ‘opacity’.
After a wood load has been burning on high for 5 to 15 minutes on High to achieve the following burn rates set the
controls as listed below:
MEDIUM HIGH:
Close the Primary Air Control to 1” to 2-1/2” (25mm to 64mm) open. Start-Up Air is closed.
MEDIUM
: Close the Primary Air Control to 3/4” to 1” (19mm to 25mm) open. Start-Up Air is closed.
LOW:
Gradually close down the Primary Air Control by pulling out making sure to maintain flames in the insert. (Start-Up Air is closed).
It is very important to maintain flames in your insert during the first few hours of a low burn to avoid excessive air pollution.
OPACITY
Opacity is the measure of how clean your insert is burning and is measured in percentages. An opacity of 100% in the smoke column
from a chimney will totally obscure an object. Whereas 0% opacity means that no smoke column can be seen. A periodic check of the
opacity emitted from your chimney will enable you to burn your insert as smoke free as possible.
1.
Initial (cold) startup:
Leave fan off until your insert is hot and a good coal bed is established, approximately 30 minutes after fuel
is lit.
2.
High Burn Setting:
The fan may be left on throughout the burn.
3.
Medium or Medium High Burn Setting:
The fan should be left off until a good burn is established, then turned on a medium
or high rate.
4.
Low Burn Setting:
The fan tends to cool the insert. Leave fan off until the burn is well established; then, if you wish, turn the fan
on at a low rate.
5. The fan is equipped with a rheostat (speed control). The highest fan speed is obtained by turning the rheostat on, then adjusting back
towards “OFF” as far as possible without turning the fan off. For a low fan speed, turn the control knob clockwise as far as possible.
Remove cold ashes (not hot) from the insert at regular intervals, depending on your usage. Ashes should be placed in a metal container
with a tight fitting lid. The closed container of ashes should be placed on a non-combustible floor or on the ground, well away from all
combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be
retained in the closed container until all cinders have thoroughly cooled. Always treat ashes as if they contain hot coals.
ASH REMOVAL
FAN OPERATING INSTRUCTION
S
BTU / Hr
Below 10,000
10,000 - 15,000
15,000 - 30,000
Maximum Heat
Start-Up Air Control
Closed after 5 to 15 minutes
Closed after 5 to 15 minutes
Closed after 5 to 15 minutes
Closed after 5 to 15 minutes
Primary Control
Pull to Stop
3/4” - 1” open
1” - 2-1/2” open
Fully open
WARNING:
Do not operate with Start-Up
Air Control in the open position in excess
of 15 minutes! Risk of extreme tem-
peratures! Prolonged operation of this
stove with the Start-Up Air Control in the
open position may cause the combusti-
ble materials around the stove to exceed
safe temperature limits.
OPERATING TIPS
For maximum operating efficiency with the lowest emissions, follow these operating procedures:
1. Regardless of desired heat output, when loading stove, burn your Quadra-Fire with both air controls wide open for a minimum
of 5 to 15 minutes.
2. Regulate burn rate (heat output) by using the Primary Control (under ashcather). The Start-Up Air Control (right side) is mainly
for initial start-up and reloading.
3. Heat output settings: Follow burn rate instructions listed below.
4.
Burn only dry, well-seasoned wood.
These are approximate settings, and will vary with type of wood or chimney draft.