EN

 

EN

 

 

 

 

and blue  color is marked the cold water pipe and an arrow starting from the 
pipe in red  color - the hot water pipe. Some appliances pipes are 
additionally marked  with badges. The pipes outlets are with threading 1/2". 
A schematic diagram  for water heater connection is shown on Fig 2. When 
the water heater works  at the water pipe tank pressure and that of the 
safety valve. In the event  where the conduit pressure is greater than 0,5 
MPa it shall be required the  installation of reduce valve (pressure-
reducing valve). Where local  regulations require use of additional devices 
that are not included with the  unit supply set and are not placed in the 
packaging, these must be  purchased and installed according to 
regulations.

 

The water heater is equipped with a combined non-return-safety valve. 
The  latter  is  factory-fitted  on  the  cold  water  pipe  or  is  located  in  the 
packaging  of  the  appliance.  The  combined  non-return-safety  valve 
located  in  the  packaging  of  the  appliance  MUST  OBLIGATORY  be 
mounted on the cold  water pipe. During that installation the arrow on its 
hull  showing  the  direction  of  water  flow  through  the  valve  must  be 
followed.

 

WARNING! 

The absence or improper installation of the combined 

valve  supplied with the product is grounds for voiding the product 
warranty.

 

WARNING! 

It  is  FORBIDDEN  to  install  any  kind  of  shut-off  fittings 

between  the  combined  valve  and  the  water  heater!  It  is  absolutely 
forbidden to obstruct the lateral opening of the combined valve and/or 
to  block its lever!

 

Where the plumbing pipes are copper or of another metal, other than that 
of  the  water  tank,  or  where brass  fasteners  are used, 

it is  obligatory 

to 

install  on  the  water  tank  inlet  and  outlet  non-metallic  couplings 
(dielectric fittings).

 

ATTENTION! 

For units with heat exchangers. Any additional tubular 

outlets (excluding those of the serpentines) that will be connected with 
the  plumbing,  and  the  holes  for  additional  thermostats  and  /  or 
thermomanometer  must  be  closed  with  a  package  insert  or  other 
suitable  for  the  purpose. The  connections  must  be  sealed  for  a  water 
pressure of at  least 1.6 MPa.

 

It is recommended to set up a draining system for any dripping from the 
combined valve side opening. The draining pipe must have a constant 
downward slope and located in frost secure environment and its ends to 
be  constantly kept open to the atmosphere.

 

Once the water heater is connected to the water supply main, its water 
tank  should be filled up with water. It is carried out in the following order:

 

 

Open completely the turn-cock for hot water of the most distant 
mixing  tap.

 

Open the stop valve on pos. 4 from Fig. 2.

 

Wait for the air from the system to come out and over half a 
minute  from the fitting outlet to flow out a thick and strong water 
stream.

 

Close the turn-cock for hot water of the mixing tap.

 

lift the lever of the combined valve on pos. 5 from Fig. 2 and wait 
for  about  30-60  seconds  until  a  thick  and  powerful  stream  of 
water runs  out from the valve side opening. 

 

Loose the lever of the combined valve.

 
WARNING! 

If  no  water  is  coming  out  of  the  opening  of  the 

combined  valve or the flow is weak (during normal water pressure), 
this should be  considered as a malfunction indicating that impurities 
from the plumbing  or caused by sewage connections have blocked 
the safety valve of the  combined valve.

 

IT IS FORBIDDEN 

to proceed with appliance electric connection before 

eliminating the reason for malfunction!

 

WARNING! 

Failure to comply with the requirements for connection 

to  the  water  supply  system  may  cause  partial  filling  up  of  the  water 
tank and  malfunction of the heating element, or when the combined 
valve is not  installed at all or has been improperly installed  
this may  even cause  destruction of the water tank, the room and/or 
other  damages  to  tangible  and  intangible  property.  Such 
consequences  are  not  within  the  scope  of  manufacturer  or  seller 
warranty liabilities and shall be at the expense of  the  party,  which 
has not observed the present manual instructions.

 

WARNING! 

The combined reciprocating safety valve is one of the unit 

safety  components  ensuring  security  for  water  heater  users.  It  is 
specifically  FORBIDDEN  to  use  the  water  heater  with  a  defective  or 
removed/unmounted combined safety valve!

 

The water heater connection to the water supply system must be performed 
only by qualified persons.

 

Where necessary the safety valve may serve for draining the water out of the 
water tank. It is carried out the following order:

 

 

Disconnect  the  heater  from  the  electrical  power  supply  network  with 
the optional device and for greater security disconnect the fuse in the 
heater phase circuit.

 

Cut the cold water access to the appliance - close the stop cock, pos. 4 
from Fig. 2.

 

Open the hot water cock on the tap or disconnect the tank hot water 
pipe (outlet pipe) connection.

 

Lift the lever of the combined valve 5 in Fig. 2 and wait until the water 
stops flowing out of the valve opening.

These steps do not still secure the complete draining of the water out of the 
tank. It is completed only by a qualified person because it requires complete 
disconnection  of  the appliance  electric circuit and  dismantling the  water  tank 
flange.

 

WARNING! 

IT IS STRICTLY PROHIBITED to turn on the heater power 

while the water tank is partially or completely emptied of water! Do not 
forget to fill the tank with water before putting it back into operation.

 

WARNING! 

The  coolant  circulation  through  the  heat  exchanger  of  a 

water  heater  equipped with such  device is PROHIBITED when the water 
tank is partially or completely emptied of water.

 

WARNING! 

When draining the water out of the water tank all necessary 

precautions must be taken to prevent damages from flowing out water.

 

 

CONNECTING  THE  HEAT  EXCHANGER  OF 
WATER  HEATER  TO  THE  ALTERNATIVE  HEAT 
SOURCE CIRCUIT

 

The water heater with heat exchanger must be connected to the alternative 
heat source in accordance with the special additional instructions provided 
by the company responsible for the installation and connection of the heater 
design. It is mandatory to install all supplied and/or recommended  by  this 
company safety, control and coolant movement management devices.

 

WARNING! 

It is prohibited to fit stop valves on heat exchanger both ends 

(inlet and outlet) simultaneously. In cases where the water heater heat 
exchanger  shall  not  be  used  and  is  not  connected  to  the  heat  source 
circuit, it must  be filled  with propylene  glycol solution suitable for  heating 
systems.

 

Connecting  the  heat  exchanger  of  the  water  heater  to  an  alternative  heat 
source  circuit  must  be  completed  only  by  qualified  technicians  in  the  field 
from  a  company  specializing  in  such  services  and  in  accordance  with  the 
design.

 

 

WATER HEATER CONNECTION TO THE POWER 
SUPPLY NETWORK

 

WARNING! 

Do  not  proceed  to  connect  the  water  heater  to  the  power 

supply network unless you have made sure that its water tank is full with 
water! Check!

 

The  water  heater  is  an  appliance  with  protection  degree  against  current 
damages Class I, which requires its compulsory connection to the earthling 
circuit of the power supply installation.

 

The water heaters models electric circuit schema are shown on Fig. 4.The 
electric power supply of the water heater is 230 V~ and is performed by a

 

separate  current  circuit  of  insulated  three-core  supply  cable  with  a  cross- 
section  of  each  of  the  wires  of  2,5  mm

(phase,  neutral  and  grounding). 

Therefore if the in-wall cable is two-wire, a  qualified electrician must add a 
third,  protective  conductor  with  no  interruption  on  its  track  from  the 
switchboard to the water heater.  
 
If the earthling conductor/wire has  intermediate connections, latter must be 
secured  against  loosening.  Otherwise  the  appliance  shall  not  be  correctly 

Содержание TREND 50 CERAMIC

Страница 1: ...TRIC WATER HEATERS 50 120 designed for wall installation MANUAL FOR INSTALLATION OPERATION AND MAINTENANCE ELEKTRICK OHRIEVA VODY TREND CERAMIC 50 120 Ur en na mont na stenu N VOD NA IN TAL CIU OBSLUH...

Страница 2: ...r inlet Vstup vody 2 Water outlet V stup vody 3 Combined valve Kombinovan ventil 4 Switch Prep na 5 Thermostat Termostat 6 Anode tester An da ntester N kres Vykurovacie keramick teleso s pr rubou 1 24...

Страница 3: ...0 7 0 7 0 7 0 7 0 7 0 7 0 7 Nap janie V 230 230 230 230 230 230 230 Elektrick v kon kW 2 2 2 2 2 2 2 2 2 Mix vody ohriatej na 40 C L 70 118 120 144 188 217 322 Hmotnos s balen m kg 21 5 30 0 28 33 37...

Страница 4: ...stup vody 4 Stop cock Uz ver 5 Combined valve Kombinovan ventil 6 Reducing valve Reduk n ventil 7 Cold water Studen voda 8 Hot water Tepl vody EN SK 1 Thermal cut out Tepeln poistka 2 Thermostat Term...

Страница 5: ...objektu s elezobet nov A 4 B EN SK 1 Wall Stena 2 Plate Doska 3 Stud ap skrutka 4 Nut Matica EN SK 1 Plate 4 60 360 Doska 4 60 360 2 Appliance plate Doska ohrieva a 3 Bolt stud 10 Skrutka ap 10 4 Nut...

Страница 6: ...nd in such state its use is strictly forbidden ATTENTION Connecting the tank with integrated heat exchangers to a local heating system solar and or other water heating systems using water or water sol...

Страница 7: ...be drained out of the water tank The type and nature of wall construction material the appliance dimensions the way of fixing it the location of its fixing elements and tubes its protection against d...

Страница 8: ...or other damages to tangible and intangible property Such consequences are not within the scope of manufacturer or seller warranty liabilities and shall be at the expense of the party which has not o...

Страница 9: ...ndicates that the water has reached adjusted temperature and the heater is switched off You may switch off the appliance by pressing the end of the button of the glowing key marked 0 The water heater...

Страница 10: ...nance operation you carry out a review of the enameled tank anode condition These services are not subject to warranty coverage andmust be performedonly by qualified person WARNING In order to ensure...

Страница 11: ...nty period of 24 months is provided for all electrical components of water heaters without the possibility of extension The warranty conditions and the complaint process must be followed in accordance...

Страница 12: ...e pr stroja k vodi om pod pr dom ak ochrann mu obvodu je obzvl d le it Pred pripojen m k elektrickej sieti mus by z sobn k teplej vody naplnen vodou Nedodr anie po iadaviek na elektrick pripojenie m v...

Страница 13: ...eduj cimi p smenami a slicami Prv dve p smen a nasleduj cich p slic ozna uj z kladn model zariadenia xxx prv tri slice za p smenami n zvom TREND s k dom pre rozsah kapacity ohrieva a vody CERAMIC s ke...

Страница 14: ...1 6 MPa Odpor a sa nastavi vyp ac syst m pre ak ko vek kvapkanie z otvoru na strane kombinovan ho ventilu Vyp acie potrubie mus ma kon tantn sklon smerom nadol a mus by umiestnen v mrazuvzdornom pros...

Страница 15: ...kon 3 kW In tal cia mus by vykonan v s lade s platn mi predpismi Vytiahnut m z str ky nap jacieho k bla zo z suvky sa ohrieva vody vypne Chybn a alebo nevhodn elektrick in tal cia a alebo z suvka s v...

Страница 16: ...ln m blikan m displeja S pokro il m opotrebovan m sa ve kos osvetlenej asti zmen uje Konkr tnej ie je tento proces op san v dodato nom n vode na obsluhu ktor sa t ka funkci elektronickej riadiacej dos...

Страница 17: ...mechanick ch s ast Pred enie z ruky je podmienen servisnou prehliadka pred uplynut m tandardnej 24 mesa nej z ru nej doby Servisn prehliadka nie je s as ou poskytovan ch z ruk a v etky n klady spojen...

Страница 18: ...SK SK Dod vate Q TERMO s r o Hlavn ulica 487 018 64 Ko eca Slovensk republika...

Отзывы: