background image

 

 

HARDWARE INSTALLATION AND REFERENCE GUIDE 

 
 

www.qtech.ru 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

QSW-6200 Series Switch 

Hardware Installation and Reference V1.0 

Содержание QSW-6200-32T

Страница 1: ...HARDWARE INSTALLATION AND REFERENCE GUIDE www qtech ru QSW 6200 Series Switch Hardware Installation and Reference V1 0 ...

Страница 2: ...t or any portion of this document in any form or by any means without the prior written consent of QTECH is prohibited Exemption Statement This document is provided as is The contents of this document are subject to change without any notice Please obtain the latest information through the QTECH website QTECH endeavors to ensure content accuracy and will not shoulder any responsibility for losses ...

Страница 3: ...the same time it is assumed that the users are already familiar with the related terms and concepts Obtaining Technical Assistance QTECH Website http www qtech ru Technical Support https helpdesk qtech ru Related Documents Documents Description Configuration Guide Describes network protocols and related mechanisms that supported by the product with configuration examples Command Reference Describe...

Страница 4: ...at is only one port of them is available at a particular time SFP port supports both 10Gbase R and 1000base X QSW 6200 series switches have the following external ports MGMT port This port is a 10 100 1000M management port It is used to connect with an Ethernet port of a PC to perform program It also supports Data Center Manageability Interface DCMI protocol and users can do remote management and ...

Страница 5: ...ation wiring For AC input the socket outlet shall be installed near the equipment and shall be easily accessible Because the device has several power supplies disconnect all of them to switch off the device When installing the unit always make the ground connection first and disconnect it last The device must be connected permanently to the protection ground before an operation The cross sectional...

Страница 6: ...n Speed adjustment and fault alarm Temperature Alarm Supported Dimensions W x D x H 440 mm x 280 mm x 44 mm Weight 3 9 kg Product Appearance The QSW 6200 32T Ethernet switch provides 28 10 100 1000Base T Ethernet ports 4 GE SFP combo ports 4 10GE SFP ports 1 MGMT port 1 USB port 1 Mini USB port and 1 Console port on the front panel as well as 2 power module slots and 2 expansion module slots on th...

Страница 7: ... 1 2 Front Panel of QSW 6200 32T Note 1 System status LED 2 Power status LED PWR1 3 Power status LED PWR2 4 MGMT port status LED 5 Console port 6 10 100 1000 Base T auto sensing Ethernet port 7 Switch port status LED 8 USB port 9 Mini USB port 10 MGMT port 11 GE SFP port 13 10GE SFP port Back Panel Figure 1 3 Back Panel of QSW 6200 32T ...

Страница 8: ...wo modules are available the switch is powered in current sharing mode When the switch is powered by the dual power modules if the system working power is greater than the capacity of single power module power redundancy cannot work if one power module fails the switch system will be affected Heat Dissipation The QSW 6200 32T is designed with left and right fans for heat dissipation thereby ensuri...

Страница 9: ...power supplies immediately Solid red The switch is faulty For details see the chapter Troubleshooting Power status LED PWR1 PWR2 Off The power module is not in place or not receiving power Solid green The power module is connected and can supply power Solid yellow The power model is identified but not recognized Solid red The redundant power is faulty or the AC power cord is not connected MGMT por...

Страница 10: ...mitting traffic at 100 Mbps 10 100 1000Base T auto sensing Ethernet port status LED 1 28 Off The port is not connected Solid green The port is connected at 1000 Mbps Blinking green The port is receiving or transmitting traffic at 1000 Mbps Solid yellow The port is connected at 10 100 Mbps Blinking yellow The port is receiving or transmitting traffic at 10 100 Mbps 1 2 QSW 6200 52T Technical Specif...

Страница 11: ...idity Operating humidity 10 to 90 RH Storage humidity 5 to 95 RH Fan Speed adjustment and fault alarm Temperature Alarm Supported Dimensions W x D x H 440 mm x 300 mm x 44 mm Weight 4 2 kg Product Appearance The QSW 6200 52T Ethernet switch provides 48 10 100 1000Base T Ethernet ports 4 10GE SFP ports 1 MGMT port 1 USB port 1 Mini USB port and 1 Console port on the front panel as well as 2 power m...

Страница 12: ...el Figure 1 6 Front Panel of QSW 6200 52T Note 1 System status LED 2 Power status LED PWR1 3 Power status LED PWR1 4 MGMT port status LED 5 Console port 6 10 100 1000Base T auto sensing Ethernet port 7 Switch port status LED 8 USB port 9 Mini USB port 10 MGMT port 11 10GE SFP port Back Panel Figure 1 7 Back Panel of QSW 6200 52T ...

Страница 13: ...wered in current sharing mode When the switch is powered by the dual power modules if the system working power is greater than the capacity of single power module power redundancy cannot work if one power module fails the switch system will be affected Heat Dissipation QSW 6200 52T adopts left and right fans for heat dissipation thereby ensuring the normal function of the device in the specified e...

Страница 14: ...tely Solid red The switch is faulty For details see the chapter Troubleshooting Power status LED PWR1 PWR2 Off The power module is not in place or not receiving power Solid green The power module is connected and can supply power Solid red The redundant power is faulty or the AC power cord is not connected MGMT port status LED MGMT Off The port is not connected Solid green The port is connected at...

Страница 15: ...ted at 10 100 Mbps Blinking yellow The port is receiving or transmitting traffic at 10 100 Mbps 1 3 QSW 6200 32F Technical Specifications Model QSW 6200 32F Expansion Module Slot 2 slots Power Module Slot 2 slots AC input Rated voltage 100V to 240V Maximum voltage 90V to 264V Frequency 50 60 Hz Rated current per input 2 A HVDC input Rated voltage 120V to 340V Maximum voltage 110V to 380V Rated cur...

Страница 16: ...dity 5 to 95 RH Fan Speed adjustment and fault alarm Temperature Alarm Supported Dimensions W x D x H 440 mm x 300 mm x 44 mm Weight 4 2kg Product Appearance The QSW 6200 32F Ethernet switch provides 28 GE SFP ports 8 10 100 1000Base T GE combo ports 4 10GE SFP ports 1 MGMT port 1 USB port 1 Mini USB port and 1 Console port on the front panel as well as 2 power module slots and 2 expansion module ...

Страница 17: ...QSW 6200 32F supports two power modules For details see the section Power Modules Dual power input The switch can be powered by one power module or two power modules When both two modules are available the switch is powered in current sharing mode When the switch is powered by the dual power modules if the system working power is greater than the capacity of single power module power redundancy ca...

Страница 18: ... indicates errors Blinking green 10Hz Supports remote on off to locate the switch Solid green The switch is operational Solid yellow Temperature alarm 1 Temperature of inlet outlet air exceeds the normal operating temperature range 2 The power supplies cannot support the whole system Check the working environment of the switch and power supplies immediately Solid red The switch is faulty For detai...

Страница 19: ... not connected Solid green The port is connected at 1 10 Gbps Blinking green The port is receiving or transmitting traffic at 1 10 Gbps GE SFP port status LED 1F 28F Off The port is not connected Solid green The port is connected at 1000 Mbps Blinking green The port is receiving or transmitting traffic at 1000 Mbps Solid yellow The port is connected at 100 Mbps Blinking yellow The port is receivin...

Страница 20: ...itch Extension Module Manual 1 5 Power Modules At present the QSW 6200 series switches support the swappable QSW M 6200 PWR and QSW M 6200 PWR2 power module The QSW M 6200 PWR power module provides AC HVDC input and DC output 12V voltage output and up to 70W power output to the switch And the QSW M 6200 PWR2 power module provides DC input 12V voltage output and up to 70W power output to the switch...

Страница 21: ...s protection over over voltage current input output short circuit output and so on I2C Communication Allows the host to communicate with the power module by I2C Power Supply Redundancy Supports dual power modules to cooperate in parallel enabling PE with 1 1 redundancy and redundant power supplies with current sharing Hot Swapping Supports to disconnect one redundant power module from the outside ...

Страница 22: ...10 000 m Features Feature Description Conformal Coating Protects circuits against moisture frog mould electrical shock and leakage and so on Protection Provides protection over over voltage current input output short circuit output and so on I2C Communication Allows the host to communicate with the power module by I2C Power Supply Redundancy Supports dual power modules to cooperate in parallel ena...

Страница 23: ...es Switch Hardware Installation and Reference Guide 23 www qtech ru LED LED Panel Identification State Meaning Status LED OUT Off There is no power input or input under voltage Solid green The module is operational ...

Страница 24: ...moving the device turn off all power supplies and dismantle all power modules 2 1 3 Electricity Observe local regulations and specifications when performing electric operations Relevant operators must be qualified Carefully check any potential danger in the working area such as ungrounded power supply unreliable grounding of the power supply and damp wet ground or floor Find out the location of th...

Страница 25: ...rer and leather plant If the pollution source is unavoidable the machine room should be located on the windward side of the pollution source perennially with advanced protection The machine room should be at least 3 7km away from the sea or salt lake Otherwise the machine room must be sealed with air conditioner installed for temperature control Saline soil cannot be used for construction Otherwis...

Страница 26: ...e and humidity in the room must be stable to ensure the device s proper functioning and prolong its service life Continuous improper temperature and humidity will cause damage to the device High relative humidity will reduce the insulation of insulation materials and cause electric leakage Sometimes it may lead to changes in the mechanical characters of materials and rust metal components Low rela...

Страница 27: ...ounding operations properly as required The correct connection of grounding lines guarantees the lighting and interference resistance of switches and must be performed with precision Safety Grounding The equipment using AC power supply must be grounded by using the yellow green safety grounding cable Otherwise when the insulating resistance decreases the power supply and the enclosure in the equip...

Страница 28: ...rence and conducted interference Power normally RF power transmitted from a device through space to a sensor is called radiated interference The origin of the interference source can either be part of or a unit separated electrically from the interfered system Conducted interference is transmitted through magnetic wires or signal cables from the source origin to sensors Generally conducted interfe...

Страница 29: ...In addition pay attention to the Tx and Rx directions of the fiber The Tx end of this device should be connected to the Rx end of the peer device and the Rx end of this device to the Tx end of the peer device 2 4 Installation Tools List of Installation Tools Common Tools Phillips screwdriver flat head screwdriver related electric cables and optical cables bolts diagonal pliers straps Special Tools...

Страница 30: ...power cables are already laid out and whether the requirements of electrical current are met Whether related network cables are already laid out 3 3 Installing the Switch Precautions During installation note the following points Connect the power cables of different colors to the corresponding grounding posts Ensure that the connected power cables have sound contact Do not place heavy items on the...

Страница 31: ...front panel of the switch to the rack For safety purposes screw up the distributed screws as shown in the 3 1 Figure 3 1 Attaching the Mounting Bracket to the Switch 3 3 2 Mounting the Switch on the Wall The QSW 6200 series switches can be mounted on a wall with the supplied mounting brackets as shown in Figure 3 2 Figure 3 2 Attaching the Mounting Brackets to the Switch for Wall Mounting 3 3 3 Mo...

Страница 32: ...r module with one hand and hold the end of the power module with the other hand Insert it into the chassis along the guide rail uprightly and slowly until a click is heard and make sure that it is in good contact with the power slot Figure 3 5 Installing a Power Module Insert the power module smoothly Please pay attention to the direction of the power panel to avoid wrong insertion If it is diffic...

Страница 33: ... the handle of the power module with one hand and hold the end of the power module with the other hand Insert it into the chassis along the guide rail uprightly and slowly until a click is heard and make sure that it is in good contact with the power slot The three screws are the input terminals of the DC power module Remove the screws and then put the ends of power cables in place before driving ...

Страница 34: ...oving an QSW M 6200 PWR2 Power Module Step 1 Press the plug of the power module Hold on to the module handle with one hand to pull out part of the module hold the bottom of it with the other hand and pull out the power module uprightly and slowly Step 2 Install a baffle in the power module slot and put the removed power module into its package Figure 3 9 Removing a Power Module Remove the power mo...

Страница 35: ... PE If not the personnel shall connect the grounding lug of the AC socket with the PE by using a grounding connector The AC socket shall be installed near the equipment and shall be easily used When installing the switch make sure the grounding is connected first and disconnected last The cross sectional area of PE conductor shall be at least 2 5 mm2 12AWG 3 7 Connecting the External Port Cables P...

Страница 36: ...h sides of the chassis fasten the fibers and twisted pairs to the cabinet cable management ring or cabling chute For the power cables you should bundle them closely along the bottom of the chassis in a straight line wherever possible 3 9 Checking after Installation Before checking the installation switch off the power supply to avoid any personal injury or damage to the component due to connection...

Страница 37: ...port of the PC Connect the RJ45 end of the Console cable to the Console port of the switch Step 2 Connect the USB Mini USB ports Connect the USB end of the cable to the USB port of the PC Connect the Type B Mini USB end of the cable to the Mini USB port of the switch QSW 6200 supports Mini USB Console combo by the Mini USB Console driver which can be downloaded on the TI website If both the Mini U...

Страница 38: ...s 95 98 NT 2000 XP Step 2 Set terminal parameters The parameters are as follows baud rate 9600 data bit 8 parity check none stop bit 1 and flow control as none Choose Setup Program Attachment Communication Super Terminal Choose Cancel to display the following page Figure 4 2 Enter the name of the new connection and click OK to display the following page Choose the series port used currently in the...

Страница 39: ...minal page 4 2 Power on Startup Checking before Power on The switch is fully grounded The power cable is correctly connected The power cable is buckled after connected The power supply voltage complies with the requirement of the switch The console cable is correctly connected the terminal can be a PC used for configuration is already started the parameters are already configured Checking after Po...

Страница 40: ...QSW 6200 Series Switch Hardware Installation and Reference Guide 40 www qtech ru Check that information is displayed on the terminal interface Check that the device LEDs are normal ...

Страница 41: ...modules in which case you should apply RPS modules When the power status LED is red check whether or not the power cable is in place and operational if not problem it means the power supply is faulty in which case you should replace it promptly When the LED of expansion modules is blinking or red it means the expansion modules are faulty in which case you should plug and check the modules The fast...

Страница 42: ...nce When the power supply fails you only need to disconnect the power cable unplug the power module replace it with a qualified one and then connect the power cables tightly Replacing Lithium Battery The built in lithium batteries can support the real time clock of the QSW 6200 switch without external power supply Please contact the TAC of QTECH for replacing lithium batteries Technical staff of Q...

Страница 43: ... work Fault Description The Status LED of each service module is OFF the Power LED of the fan tray is OFF and the fan does not work The LED on the panel of the power module is OFF The fan does not work Troubleshooting First place the switches of all the power modules to OFF Check if the cables of the cabinet have been correctly connected Check whether the power cables are tightly connected to the ...

Страница 44: ...ly inserted expansion module still cannot be powered on please contact TAC of QTECH for technical support Fault 6 The link cannot be set up between fiber interfaces Fault Description The system runs normally After the fiber interface is inserted into the optical module and the optical fiber is properly connected the link cannot be set up Troubleshooting First confirm whether the interface is a cop...

Страница 45: ...o 100 m The 1000BASE T port uses four pairs of wires for transmission all of which must be connected Figure A 1 shows the connections of the twisted pairs used by the 1000BASE T port Figure A 1 Schematic Diagram for the Four Twisted Pairs of the 1000BASE T In addition to the above cables the 100BASE TX 10BASE T can also use 100 ohm Category 3 4 5 cables for 10 Mbps and 100 ohm Category 5 cables fo...

Страница 46: ...Twisted Pairs of the 100BASE TX 10BASE T Optical Fiber Connection For the optical fiber ports select single mode or multiple mode optical fibers for connection according to the fiber module connected The connection schematic diagram is shown in Figure A 4 Figure A 4 Schematic Diagram for optical fiber connection ...

Страница 47: ...ractical requirement Precautions for installation Make sure that the PE terminal of the power arrester has been well grounded After connecting the switch AC power plug to the socket of the power arrester lightning protection socket lightning protection function implements if the RUN LED is Green and the ALARM LED is OFF If the ALARM LED on the power arrester is Red you shall check what the reason ...

Страница 48: ...istance of the switch grounding terminal cut the grounding line for the Ethernet port arrester and firmly tighten the grounding line to the grounding terminal of the switch Use the multimeter to check whether the grounding line for the arrester is in good contact with the switch grounding terminal and the framework According to the description on the Ethernet Port Arrester Hardware Installation Gu...

Страница 49: ... the Ethernet port arrester Reversed direction of the arrester installation You shall connect the external network cable to the IN end and connect the switch Ethernet port to the OUT end Poor arrester grounding The length of the grounding line should be as short as possible to ensure that it is in good contact with the switch grounding terminal Use the multimeter to confirm the contact condition a...

Страница 50: ...ll diameter The minimum bend radius of a coaxial cable should be 7 times the overall diameter of the cable If the cable is constantly bent plugged or unplugged the bend radius should be 10 times the overall diameter The minimum bend radius of a high speed cable such as an SFP cable should be 5 times the overall diameter of the cable If the cable is constantly bent plugged or unplugged the bend rad...

Страница 51: ...from sharp edges Holes in metal through which cables pass shall have smooth well rounded surfaces or be protected with insulating bushings Use proper cable ties to bind cables together Do not tie two or more cable ties to bind cables Cut off excess cable tie cleanly with no sharp edges after bundling cables as shown in Figure C 2 Figure C 2 Cutting off Excess Cable Tie If cables are to be bent bin...

Страница 52: ...th of the cable connecting moving parts such as the ground wire of the cabinet door to avoid stress on the cable when moving parts are in place ensure the excess cable length shall not contact heat sources sharp corners or edges If heat sources are unavoidable use high temperature cables instead When using screws to fasten cable lugs the bolts or nuts shall be tightened and prevented from loosenin...

Страница 53: ...e same direction into groups Keep cables clean and straight Cables shall be tied according to the following table Diameter of Cable Bundle mm Space between Bundles mm 10 80 to 150 10 to 30 150 to 200 30 200 to 300 Do not tie knots for cables or cable bundles The metal parts of the cold pressed terminal blocks such as air circuit breakers shall not be exposed outside of the blocks ...

Страница 54: ...onsole driver can be downloaded on the official TI website http www ti com The driver is now supported only on 32 bit Windows XP 64 bit Windows XP 32 bit Window Vista 64 bit Window Vista 32 bit Windows 7 and 64 bit Windows 7 Installation Steps Step 1 Double click the Setup file and choose Next Step 2 Accept the License Agreement and click Next ...

Страница 55: ...QSW 6200 Series Switch Hardware Installation and Reference Guide 55 www qtech ru Step 3 Select the unpackage directory and click Install Step 4 After the driver is installed click Finish ...

Страница 56: ...vices with Mini USB ports using Type A male USB to male Mini USB cables Right click Computer choose Manage Device Manager Ports COM LPT you will see the TUSB3410 Device Change the serial port number to the port number of TUSB3410 Device and then perform system commissioning If you cannot find TUSB3410 Device there re install it or change the Type A USB to Mini USB cables ...

Отзывы: