background image

COUNTING: 

 

Once the Unit Weight has been determined through the sampling process you may begin 
adding additional pieces to the scale. The count will be displayed incrementally in the display 
window. The count will continue to accumulate until the maximum weight capacity of the scale is 
reached. If you exceed the rated weight capacity the WEIGHT window will display an error. 
Remove some items from the platter until the quantity is once again visible. 

TARING 

(Zeroing):

 

 

This feature allows you to count paper inside a box or carton by first eliminating the weight of 
the container. It also allows for the use of a “expansion” or oversized platter for counting items 
which exceed the built-in platter dimensions. You can sample first and then tare out a weight, or 
you can tare out a weight and then sample with the container on the scale. Remember that the 
weight should always be “0” before sampling.  

Function

 

Procedure

 

To Eliminate the Weight of a Box or 
Expansion Platter 

*

 

Place the container or expansion platter on the 
scale and press the 

TARE

 key. 

NOTE: The 

scale must be in the  grams, lbs, or oz. 
mode for the Tare function to work. Press 
the UNITS key to advance to one of these 
settings if you are currently in the PCS 
(pieces) mode.

 

To Eliminate a “Negative” Tare 
Weight

 

Press 

TARE

 key with nothing on the platter. 

NOTE: The scale must be in the  grams, 
lbs, or oz. mode for the Tare function to 
work. Press the UNITS key to advance to 
one of these settings if you are currently in 
the PCS (pieces) mode.

 

Item Type

 

Sampling Procedure

 

Coins or Tokens

 

Press the NET/GROSS key to cycle through the 
available samples sizes and select: 

C100

 

COIN SAMPLING: 

FUNCTION:  

 Counting 

Содержание ECS Series

Страница 1: ...Email info QTechScales com Web Site www QTechScales com Installation and Operating Instructions The Perfect Counting Scale for Any Application Copies of this manual are available in Adobe Acrobat PDF format on our website Counting Weighing Shipping Inventory Control Batching 5 10 or 20 lb Capacity ...

Страница 2: ...ndicator arrow will appear above the oz symbol on the display Locate your scale on a solid level work surface free from air drafts and vibrations While precise leveling of the scale is not required you may get inaccurate results if all four adjustable feet are not in contact with the work surface For Consistent and Accurate Results Avoid scale placement near windows fans and air conditioning or he...

Страница 3: ... pieces and place that exact amount of items on the scale Next press the UNITS key CAL will appear and then the scale will display the selected sample size in the window Select from the following sampling procedures depending on the item you wish to count FUNCTION How to Sample 2 Sheet Size Sampling Procedure 8 1 2 x 11 Press the NET GROSS key to cycle through the available samples sizes and selec...

Страница 4: ...rst and then tare out a weight or you can tare out a weight and then sample with the container on the scale Remember that the weight should always be 0 before sampling Function Procedure To Eliminate the Weight of a Box or Expansion Platter Place the container or expansion platter on the scale and press the TARE key NOTE The scale must be in the grams lbs or oz mode for the Tare function to work P...

Страница 5: ...ng is uniform in weight the scale will always display the correct count plus or minus one or two pieces per thousand Incorrect counts are most often the result of one or more of the following factors A Miscount During Sampling The scale is dependent on the operator for the accuracy of the sampling count If you set the scale for a 50 piece sampling but there are actually only 49 pieces you will get...

Страница 6: ...e CALIBRATION Calibration Instructions Procedure for the ECS 5 5 lb Capacity Press the ON ZERO key once The scale will read 02CAL Press the TARE key once The scale will display 2500 with last 0 blinking Press the ON ZERO key once Press the TARE key The scale will first display CEntr and then 2500 Place 2500 grams on the scale in the form of a certified test weight allow the display to stabilize an...

Страница 7: ...Resolution 1 Part in 300 000 Capacities 3 lbs QCS 3 6 lbs QCS 6 15 lbs QCS 15 30 lbs QCS 30 65 lbs QCS 65 Resolution 1 Part in 600 000 QCS 3 1 part in 2 000 000 QCS Series For Fast One Button Counting of Pennies Nickels Dimes Quarters Fifty cent pieces and Dollar Coins Capacity 60 lbs EZ 60 Resolution 1 Part in 600 000 EZ 60 High Capacity Heavy Duty Counting Scale with Detachable Console Capacity ...

Страница 8: ...ech you can always expect 90 DAY money back guarantee A Full 3 YEAR Product Warranty TOLL FREE phone technical support at no charge for as long as you own the scale PROFESSIONAL courteous and timely response to your inquiries questions or concerns Customer Satisfaction is the Driving Force at QTech 129 Cramer Road Jewett New York 12444 USA 800 831 4175 518 734 6514 Fax 518 734 6497 Email info QTec...

Отзывы: