Remove the contents from the carton which includes the scale, platter, and the AC adaptor. 
 
Install the platter by inserting the pins on the underside into the holes on the top of the scale 
console. The beveled edge of the platter should face forward. 

 

The scale may be powered either with 4 ’C’ Cell batteries or the supplied AC adapter. If using 
batteries, do not use a mixture of old and new batteries. Once the batteries loose power, 
replace them with fresh ones or remove them from the scale. Depleted batteries left in the scale 
may cause the unit to fail when operated on the AC adaptor. 
 
Insert the plug into the jack on the rear of the unit and then plug the transformer into a standard 
110/120 volt AC outlet. The use of a surge protector is recommended. 
 
Turn the scale on by pressing the ON/ZERO key. 
 
The ECS scale can display grams, pieces (pcs), ounces (oz), or pounds (lbs.). When the scale 
is set to ounces, an indicator arrow will appear above the oz symbol on the display. 
 
Locate your scale on a solid, level work surface free from air drafts and vibrations. While precise 
leveling of the scale is not required, you may get inaccurate results if all four adjustable feet are 
not in contact with the work surface. 

For Consistent and Accurate Results: 

 



Avoid scale placement near windows, fans, and air conditioning or heating vents. Do 
not leave anything on the scale platter when not in use.

 



Use a surge protector with the AC adaptor to minimize the effects of voltage spikes. 

 



Do not jog paper/parts or drop cartons on the scale platter.

  



To avoid electronic interference do not operate cell phones within 6 feet of the scale. 

Important:  Save the shipping carton and all packing materials should it be necessary to return the 

unit to the factory for service.  

CAUTION: 

The AC adaptor supplied with the scale is a proprietary design. If it should 

ever fail, replace only with a QTech unit. The use of any other adaptor may result in 
scale and/or battery damage as well as voiding your warranty.  

SET-UP:  

 Preparing the Scale for Use 

Содержание ECS Series

Страница 1: ...Email info QTechScales com Web Site www QTechScales com Installation and Operating Instructions The Perfect Counting Scale for Any Application Copies of this manual are available in Adobe Acrobat PDF format on our website Counting Weighing Shipping Inventory Control Batching 5 10 or 20 lb Capacity ...

Страница 2: ...ndicator arrow will appear above the oz symbol on the display Locate your scale on a solid level work surface free from air drafts and vibrations While precise leveling of the scale is not required you may get inaccurate results if all four adjustable feet are not in contact with the work surface For Consistent and Accurate Results Avoid scale placement near windows fans and air conditioning or he...

Страница 3: ... pieces and place that exact amount of items on the scale Next press the UNITS key CAL will appear and then the scale will display the selected sample size in the window Select from the following sampling procedures depending on the item you wish to count FUNCTION How to Sample 2 Sheet Size Sampling Procedure 8 1 2 x 11 Press the NET GROSS key to cycle through the available samples sizes and selec...

Страница 4: ...rst and then tare out a weight or you can tare out a weight and then sample with the container on the scale Remember that the weight should always be 0 before sampling Function Procedure To Eliminate the Weight of a Box or Expansion Platter Place the container or expansion platter on the scale and press the TARE key NOTE The scale must be in the grams lbs or oz mode for the Tare function to work P...

Страница 5: ...ng is uniform in weight the scale will always display the correct count plus or minus one or two pieces per thousand Incorrect counts are most often the result of one or more of the following factors A Miscount During Sampling The scale is dependent on the operator for the accuracy of the sampling count If you set the scale for a 50 piece sampling but there are actually only 49 pieces you will get...

Страница 6: ...e CALIBRATION Calibration Instructions Procedure for the ECS 5 5 lb Capacity Press the ON ZERO key once The scale will read 02CAL Press the TARE key once The scale will display 2500 with last 0 blinking Press the ON ZERO key once Press the TARE key The scale will first display CEntr and then 2500 Place 2500 grams on the scale in the form of a certified test weight allow the display to stabilize an...

Страница 7: ...Resolution 1 Part in 300 000 Capacities 3 lbs QCS 3 6 lbs QCS 6 15 lbs QCS 15 30 lbs QCS 30 65 lbs QCS 65 Resolution 1 Part in 600 000 QCS 3 1 part in 2 000 000 QCS Series For Fast One Button Counting of Pennies Nickels Dimes Quarters Fifty cent pieces and Dollar Coins Capacity 60 lbs EZ 60 Resolution 1 Part in 600 000 EZ 60 High Capacity Heavy Duty Counting Scale with Detachable Console Capacity ...

Страница 8: ...ech you can always expect 90 DAY money back guarantee A Full 3 YEAR Product Warranty TOLL FREE phone technical support at no charge for as long as you own the scale PROFESSIONAL courteous and timely response to your inquiries questions or concerns Customer Satisfaction is the Driving Force at QTech 129 Cramer Road Jewett New York 12444 USA 800 831 4175 518 734 6514 Fax 518 734 6497 Email info QTec...

Отзывы: