background image

Sampling is the process of “teaching” your scale to calculate a unit weight or “weight per 1000” 
pieces. Once the scale knows the unit weight, it can quickly provide a count by dividing the 
weight on the scale by the unit weight. 
 
This is the most critical step in the entire counting process. The golden rule of sampling is this: 
the larger the initial sample size, the more accurate your counts will be. There is a breakeven 
point, however, at which point an increased sample size will provide little or no additional 
accuracy. We suggest you use the sampling sizes listed in the table below as a starting point. 
You may then experiment with these values to find a reasonable tradeoff between the time 
spent sampling and the resulting accuracy.  

 

Turn the scale on by pressing the ON/ZERO key. Press the UNITS key to cycle through grams, 
lbs, oz, and PCS - select “PCS”. Next press the NET/GROSS key to cycle through the available 
samples sizes: C10, C20, C50, C100, and C200. Select a sample size of 10, 20, 50, 100, or 200 
pieces, and place that exact amount of items on the scale.  
 
Next press the UNITS key - “CAL” will appear and then the scale will display the selected 
sample size in the window. 
 
Select from the following sampling procedures depending on the item you wish to count: 

FUNCTION:  

 How to Sample 

Sheet Size

 

Sampling Procedure

 

8-1/2 x 11”

 

Press the NET/GROSS key to cycle through the 
available samples sizes and select: 

C20

 

5-1/2 x 8-1/2”

 

Press the NET/GROSS key to cycle through the 
available samples sizes and select: 

C50

 

2 x 3-1/2” or Smaller Sheets

 

Press the NET/GROSS key to cycle through the 
available samples sizes and select: 

C100

 

NOTE: 

If you will be counting fewer than 1000 sheets you may use a smaller than 

normal sampling size. 

PAPER SAMPLING: 

Item Type

 

Sampling Procedure

 

Small, light weight items, such 
as beads, screws, etc.

 

Press the NET/GROSS key to cycle through the 
available samples sizes and select: 

C50

 

Medium weight items, such as 
fittings, extrusions, etc.

 

Press the NET/GROSS key to cycle through the 
available samples sizes and select: 

C20

 

Larger items, such as heavier 
castings, finished products, etc. 

Press the NET/GROSS key to cycle through the 
available samples sizes and select: 

C10

 

PARTS SAMPLING: 

Содержание ECS Series

Страница 1: ...Email info QTechScales com Web Site www QTechScales com Installation and Operating Instructions The Perfect Counting Scale for Any Application Copies of this manual are available in Adobe Acrobat PDF format on our website Counting Weighing Shipping Inventory Control Batching 5 10 or 20 lb Capacity ...

Страница 2: ...ndicator arrow will appear above the oz symbol on the display Locate your scale on a solid level work surface free from air drafts and vibrations While precise leveling of the scale is not required you may get inaccurate results if all four adjustable feet are not in contact with the work surface For Consistent and Accurate Results Avoid scale placement near windows fans and air conditioning or he...

Страница 3: ... pieces and place that exact amount of items on the scale Next press the UNITS key CAL will appear and then the scale will display the selected sample size in the window Select from the following sampling procedures depending on the item you wish to count FUNCTION How to Sample 2 Sheet Size Sampling Procedure 8 1 2 x 11 Press the NET GROSS key to cycle through the available samples sizes and selec...

Страница 4: ...rst and then tare out a weight or you can tare out a weight and then sample with the container on the scale Remember that the weight should always be 0 before sampling Function Procedure To Eliminate the Weight of a Box or Expansion Platter Place the container or expansion platter on the scale and press the TARE key NOTE The scale must be in the grams lbs or oz mode for the Tare function to work P...

Страница 5: ...ng is uniform in weight the scale will always display the correct count plus or minus one or two pieces per thousand Incorrect counts are most often the result of one or more of the following factors A Miscount During Sampling The scale is dependent on the operator for the accuracy of the sampling count If you set the scale for a 50 piece sampling but there are actually only 49 pieces you will get...

Страница 6: ...e CALIBRATION Calibration Instructions Procedure for the ECS 5 5 lb Capacity Press the ON ZERO key once The scale will read 02CAL Press the TARE key once The scale will display 2500 with last 0 blinking Press the ON ZERO key once Press the TARE key The scale will first display CEntr and then 2500 Place 2500 grams on the scale in the form of a certified test weight allow the display to stabilize an...

Страница 7: ...Resolution 1 Part in 300 000 Capacities 3 lbs QCS 3 6 lbs QCS 6 15 lbs QCS 15 30 lbs QCS 30 65 lbs QCS 65 Resolution 1 Part in 600 000 QCS 3 1 part in 2 000 000 QCS Series For Fast One Button Counting of Pennies Nickels Dimes Quarters Fifty cent pieces and Dollar Coins Capacity 60 lbs EZ 60 Resolution 1 Part in 600 000 EZ 60 High Capacity Heavy Duty Counting Scale with Detachable Console Capacity ...

Страница 8: ...ech you can always expect 90 DAY money back guarantee A Full 3 YEAR Product Warranty TOLL FREE phone technical support at no charge for as long as you own the scale PROFESSIONAL courteous and timely response to your inquiries questions or concerns Customer Satisfaction is the Driving Force at QTech 129 Cramer Road Jewett New York 12444 USA 800 831 4175 518 734 6514 Fax 518 734 6497 Email info QTec...

Отзывы: