background image

INSTRUCTION MANUAL

Summary of Contents for ProShip

Page 1: ...INSTRUCTION MANUAL ...

Page 2: ......

Page 3: ...s from the battery compartment to avoid leakage which may cause damage to this scale Avoid overloading the scale as this may cause permanent damage and void your warranty DO NOT EVER exceed the maximum capacity of the scale Keep the scale away from water this scale is not water resistant Shock injury and electrical damage can occur if used in a wet location Matter charged with static electricity c...

Page 4: ... batteries DO NOT mix type Always store unused batteries in their packaging and away from metal objects that may cause a short circuit Remove dead batteries from the product and remove batteries if you will not be using the product for an extended period Always make sure battery compartments are secure NEVER dispose of batteries in fire Risk of batteries exploding NEVER attempt to recharge normal ...

Page 5: ... weight reading will remain on the display D UNIT BUTTON Changes weighing units e g kg or lb E ZERO BUTTON Sets display to zero or Zero Range 4 to full capacity F TARE BUTTON Tare Range 100 to full capacity LCD DISPLAY G Low battery indicator H Weighing unit I Negative value indicator J ZERO indicator K Hold indicator REAR OF DISPLAY L Use 6 x AA 1 5V batteries M Battery compartment cover For wall...

Page 6: ...m onto weighing platform by pressing UNIT button WHILST ITEM IS ON PLATFORM CONVERSION If you did not choose the desired measuring unit before placing item onto platform it is still not too late to change covert it Simply press the UNIT button with the item still on the platform or when in Hold mode and the unit reading will be converted to your new chosen unit i e lb oz to kg PROGRAMMABLE FUNCTIO...

Page 7: ...play will show OFF this means auto shut off function inactive 3 SELECTION OF AUTO BACKLIGHT MODE Whilst the scale is in Change Function Mode press the UNIT button until the display will show L_ON or OFF press ZERO to choose ON or OFF selection display ON this means auto backlight function active press ZERO again the display will show OFF this means auto backlight function is inactive i e shut off ...

Page 8: ...om 999999 to 111111 and then 0 appear on the display 2 SELECT THE WEIGHING UNIT WITH UNIT Press UNIT to select a weighing unit kg lb Once the unit has been selected the selected unit will be displayed next to the weight value 3 START WEIGHING If you do not use a container for weighing Verify the reading is 0 If not press ZERO to display 0 Place the items to be weighed on the platform If you use a ...

Page 9: ...ermarket bags of pre packed sugar flour or even packs of cola cans or coins that you have had pre weighed on Legal for Trade scales in the supermarket or market The weight can be in kg g lb or oz and do not have to be whole units i e could be 10 15kg 52 73kg 12 6lb or 300 7lb HOW TO CALIBRATE It is recommended but not essential to use a total weight that is at least 50 of the total capacity So for...

Page 10: ...ation on the platform wait for a moment and then press UNIT Another 5 digit number will appear on the display which you DO NOT need to worry about Press ON OFF to turn scale off to complete and save the calibration If a mistake has been made pressing ON OFF before the end of step 3 will turn the scale off and calibration will not have taken place To test the calibration was successful turn on the ...

Page 11: ... in use Illuminated backlit LCD display programmable on off Easier reading in darker environments Stainless steel remote damage resistant display front Angle adjustable mounting bracket 1 8m cable Perfect for quick installation on any table or wall Extra large easy press buttons Displays and converts weight in lb or kg Last unit memory defaults to last unit used Low 0 05kg 0 1lb minimum weight to ...

Page 12: ...apter 9V 12V 100mA DC output optional Due to continual product improvement specifications and or appearance may change SPECIAL WARNING Mobile phones cordless phones and any radio frequency device can cause temporary interference and cause the scale to temporarily not work properly Please do not use any electronic device near the SCALE Just like in an airplane DO NOT use your mobile phone near the ...

Page 13: ...ed on Pg 9 2 MEASURED WEIGHT DOES NOT STAY STILL AND CONSTANTLY CHANGES UP OR DOWN This is usually caused by a faulty AC adapter Please test unit using a good quality set of batteries to see if this makes a difference If it does make a difference a new AC adapter can be sent under warranty by contacting your supplier 3 THE BACKLIGHT OF THE DISPLAY CONSTANTLY FLASHES ON AND OFF This is usually caus...

Page 14: ...le level to make sure display will be level 2 Using an appropriate drill two holes in the marked positions approximately 40mm deep using a 6mm drill bit 3 Insert 6mm wall plugs into the holes so that they are flush with the wall surface and then using a screwdriver tighten 4mm diameter x 35mm long screws into the wall plug leaving only 3 4mm of the screw protruding out of the wall 4 Align the hole...

Page 15: ...PROSHIP 15 NOTES ...

Page 16: ... House RM14 3SL UK TEL 44 0 871 234 7678 FAX 44 0 871 234 7688 EMAIL sales abcongroup co uk Developed in UK Engineered in USA Made in China POSTSHIP and Any Weight Calibration are registered trademarks of ABCON Worldwide Patents Pending ...

Reviews: