background image

20

Operation

 QSControl Port

The QSControl port operates on a 10BaseT Ethernet network. This port is one of the primary means for connecting QSControl.net to the 
BASIS. The port may connect directly to a PC's 10BaseT or 10/100 (auto-sensing or auto-negotiating) network interface card using a 
crossover cable. Data from the QSControl port may also pass through network repeaters, network switches and routers. We strongly 
recommend the use of network switches to facilitate higher bandwidth and dedicated connections. 

CobraNet Port

The CobraNet port operates on a dedicated 100BaseTx (Fast Ethernet) network. The CobraNet port may connect directly to a PC's 
100BaseTx or 10/100 (auto-sensing or auto-negotiating) network interface card using a crossover cable for the purposes of configura-
tion when the BASIS 904zz is in the single-wire interface mode. During normal operation (passing audio) the CobraNet port must con-
nect to a 100BaseTx or 10/100 or 10/100/1000 (auto-sensing or auto-negotiating) switch port. Optionally, the BASIS 904zz may connect 
to another CobraNet port using a crossover cable. When the BASIS 904zz is operating in the two-wire interface mode (described in fol-
lowing sections), the CobraNet port may be connected to a network repeater. Regardless of the interface mode, all CobraNet audio data 
must pass through only network switches or only network repeaters. Combinations of these devices will cause unreliable operation and 
are not supported. Likewise, the use of routers, gateways and ATM devices are not supported for the CobraNet audio path. 

CobraNet Channel Density

The BASIS 904zz will support the acquisition of up to 32 channels via up to 4 inbound bundles (from the network). Of these 32 channels, 
any 24 may be selected to forward to the signal processing chain (DSP engine). 
The BASIS 904zz will support the delivery of up to 32 channels via up to 4 outbound bundles (to the network). Of these 32 channels, up 
to 24 may be unique (processed individually... or the result of mixed signals from the DSP engine). The remaining 8 channels (if used) 
will be copies of other channels. 

CobraNet Channel Resolution

All CobraNet audio will be processed internally within BASIS 904zz at 24-bit resolution. The BASIS 904zz may receive any valid resolu-
tion off of the network. This is currently 16-bit, 20-bit and 24-bit. Audio via inbound bundles may be in any combination of these resolu-
tions and the BASIS will process the data accordingly. All DACs will process 24-bit audio, though the least significant bits may be zero 
filled if the inbound audio format is less than 24-bit resolution. 
The BASIS 904zz will support outbound (sourced onto the network) resolutions of 16-bit, 20-bit and 24-bit. The default outbound resolu-
tion is 20-bit.

CobraNet Terms and Conditions 

Single-wire interface

 offers the best efficiency and ease of network configuration for most applications. The single-wire interface 

requires fewer network ports and less cabling. Single-wire interface refers to CobraNet audio, CobraNet control and monitoring and 
QSControl.net control and monitoring using the same network connection. This mode uses the CobraNet connection to provide all data 
communications to the BASIS product. In this mode, the port must connect to a 100BaseTx or 10/100 or 10/100/1000 (auto-sensing or 
auto-negotiating) link partner. Network repeaters will not be supported and all audio must pass through network switches only. A 
QSControl Venue Manager PC may connect to the network via a repeater or router.

Two-wire or dual-wire interface

 offers the greatest versatility in network design. Separate connections allow discrete networks 

and offer support for WAN topologies on the QSControl.net-side. Two-wire or dual-wire interface refers to CobraNet audio having a 
dedicated network link and QSControl control and monitoring having a dedicated network link. In this mode, the two ports (CobraNet 
and QSControl) must be connected to separate networks. By separate networks, we mean either physically separate hardware or the 
use of common hardware with partitioned or segmented network domains such as the use of VLANs, domain bubbles or separate port 
clusters. The dual-wire interface may support dissimilar network hardware for the two port connections (see rules above for CobraNet 
and QSControl port connections).

Содержание BASIS 904zz

Страница 1: ...TD 000152 00 rev A BASIS 904zz 16 Output CobraNet Enabled Control and Monitoring Signal Processor Hardware Manual TD 000152 00...

Страница 2: ...cord 5 Reliable Earthing Grounding of rack mounted equipment should be maintained LITHIUM BATTERY WARNING THIS EQUIPMENT CONTAINS A NON RECHARGEABLE LITHIUM BATTERY LITHIUM IS A CHEMICAL KNOWN TO THE...

Страница 3: ...olling the overall BASIS QSControl system However the BASIS 904zz also offers a front panel interface for accessing critical functions A single QSControl server computer can support several cli ents r...

Страница 4: ...et are available at www qscontrol net We invite you to visit us there We ve applied our many years experience in supporting high end installed sound with our previous system building products such as...

Страница 5: ...ologies please visit http www qscaudio com products network resources htm and http www peakaudio com CobraNet background html Notes on Network Systems Design As with any communications system the reli...

Страница 6: ...P IP standards compliant network system and therefore supports operation on network repeaters switches and routers When implementing the Two Wire Interface the QSControl net segment does not require a...

Страница 7: ...2 connection while passing audio between them all without a network switch However you would have to physically connect your computer first to one unit and then to the other With this elementary conne...

Страница 8: ...is configuration works well when CobraNet audio deliveries are point to point Though the example shows only two units as many devices may be connected as there are available switch ports All BASIS RAV...

Страница 9: ...net traffic and a separate VLAN for CobraNet audio traffic This config uration essentially provides a dedicated network for QSControl including the system controller and a second dedicated network for...

Страница 10: ...ith its own network switch Therefore traffic segmentation is physical rather than logical Example 5 also pro vides an additional level of fault tolerance although at the expense of additional network...

Страница 11: ...r out of an equipment rack Rack mounting is optional Adhesive rubber feet are included for non rack mount installations Use them to prevent the unit from scratching or marring support surfaces Rack Mo...

Страница 12: ...used for real time adjustments and configuration of audio systems we recommend all Windows Power Options located in the Windows Control Panel features be disabled Display hard drive system standby and...

Страница 13: ...ntroller computer CobraNet Connection Loss If you are operating with a valid CobraNet network and the connection to the network is disrupted audio will momentarily mute allow ing the BASIS 904zz to sy...

Страница 14: ...evel and 0 5 VDC input The contact closure and logic devices accommodate on off or state change events the variable resistor input provides full 8 bit resolution allowing for incremental change events...

Страница 15: ...dio and ampli fier status monitoring This can be eight 2 channel amplifiers or two 8 channel amplifier or other suitable combinations If connecting a multi DataPort amplifier ensure all the DataPorts...

Страница 16: ...display are used to navigate through the menus The rotary select accept knob is active for many displayed items allowing you to scroll through choices by rotating the control and accepting choices en...

Страница 17: ...lt Boot Screen Right side buttons serve as up down navigation Arrow characters indi cate right side button context If additional menus are available the arrow character will be shown Main Menu Screens...

Страница 18: ...Client Server selection keep both Client and Server selected This will be appropriate for general use 8 When prompted Select Installation Folder specify the installation directory or accept the defaul...

Страница 19: ...nections verify IP addresses are set correctly ver ify Subnet masks are set correctly and verify AC power is properly applied to the BASIS 19 Click on the BASIS 904zz in the inventory root A view of a...

Страница 20: ...used will be copies of other channels CobraNet Channel Resolution All CobraNet audio will be processed internally within BASIS 904zz at 24 bit resolution The BASIS 904zz may receive any valid resolu t...

Страница 21: ...unicate with the BASIS 904zz if it is in safe mode You may communicate only using TFTP Telnet or RS 232 RS 232 Serial Port I O Interface The RS 232 connector on the rear panel is used as a serial port...

Страница 22: ...ick OK to continue If all the connections and communications settings are correct the main Hyper Terminal window will open 6 The Hyper Terminal main window will appear next but blank Type the letter h...

Страница 23: ...opening a Telnet session 1 To open the Telnet session Click Start select Run type Telnet followed by a space then the IP address of the BASIS 904zz you want to communicate with in the text box and cli...

Страница 24: ...utput 6 313 milliseconds 3 646 milliseconds Program Outputs 16 Connector Type 8 HD 15 dataport connections Cable Type QSC DataPort cable QSC p n DPC x x designates cable length in feet Available stock...

Страница 25: ...ts 6 discrete inputs for TTL logic voltage control or passive resistive Connector Type 2 pin Phoenix Style a k a Euro Style detachable terminal blocks Configuration Single ended ground referenced Pino...

Страница 26: ...suppliers be held liable for any damages consequential incidental or otherwise including any claims for lost profits and or savings resulting from any attempted integration of QSControl products with...