background image

22

Utility/Diagnostic Functions (continued)

RS-232 Communications Procedure:

1)

 Connect the 

RS-232

 port of the BASIS 904zz to an unused serial port (COM port) of a PC using a normal (straight through) serial 

cable. 

2)

 Open the 

HyperTerminal

 program. This program is usually started by clicking the Windows 

Start

 icon, selecting 

Programs

, then

 

Accessories

Communications

, and finally, highlighting the

 

Hyper Terminal

 folder and clicking on its icon.

3)

 After starting 

Hyper Terminal

,

 a 

Connection Description

 window will pop-up. It will require that you name your connection. 

Enter a name for your new connection (example: 

BASIS 904zz

) and click

 

OK 

to continue.

4)

 Next, 

Hyper Terminal 

needs to know how to “talk” to the BASIS 904zz. This selection depends on which port on your PC the cable 

is connected to. Ignore the first three entry fields (phone number information) and go directly to the 

Connect using

 entry field and click 

on the down arrow for the drop-down menu selection. Select the port the BASIS 904zz is connected to and click 

OK

 to continue. The 

Properties

 window should appear next.

5) 

The 

Properties

 

window for the selected COM

 

port should now be active. For the Port Settings, use the following information so 

communication between the BASIS 904zz and the computer is in the same “language”.

Bits per Second: 

9600

Data Bits

: 8

Parity

: none

Stop Bits: 

1

Flow Control: 

Xon/Xoff

Once you have set the properties as outlined, click 

OK 

to continue. If all the connections and communications settings are correct, the 

main 

Hyper Terminal 

window will open.

6) 

The

 

Hyper Terminal 

main window will appear next, but blank. Type the letter “h” (for help) and then press the“Enter” key. This will 

prompt the BASIS 904zz to post its menu text. The “h” key is the Help prompt for the BASIS 904zz. A text menu will appear. This is sent 
by the BASIS 904zz and will detail your options and instructions for changing the address information. 

From this main-menu you will need to make your menu choices and follow the instructions in the following sub-menus or screens. 
Although many of the instructions and tests may not pertain to a specific setup or troubleshooting situation, you may be asked to run 
certain tests by a QSC technical representative. The results of these tests will help to troubleshoot any problems.

The most common user item that might require settings to be changed would be the IP address information. This would be useful if the 
IP address was inadvertently changed to an unrecognized address and subsequently you were unable to “talk” to the BASIS 904zz over 
the network. This situation would require the 

Display Network Settings

 and 

Enter Network Setup

 items to be accessed for re-

assigning a valid IP address.

IP ADDRESS ASSIGNMENT- 
ONLY REQUIRED FOR ATTACHING TO EXISTING NETWORKS! 
DO NOT CHANGE THE COMMUNICATIONS SETTINGS OF THE BASIS 904zz UNLESS CERTAIN OF YOUR ACTIONS. THE 
FACTORY-PROGRAMMED IP ADDRESS CAN BE ACCESSED USING THE FRONT PANEL DISPLAY MENU SYSTEM. RECORD 
THIS IP ADDRESS SHOULD YOU NEED TO RETURN TO THE INITIAL SETTINGS.

Содержание BASIS 904zz

Страница 1: ...TD 000152 00 rev A BASIS 904zz 16 Output CobraNet Enabled Control and Monitoring Signal Processor Hardware Manual TD 000152 00...

Страница 2: ...cord 5 Reliable Earthing Grounding of rack mounted equipment should be maintained LITHIUM BATTERY WARNING THIS EQUIPMENT CONTAINS A NON RECHARGEABLE LITHIUM BATTERY LITHIUM IS A CHEMICAL KNOWN TO THE...

Страница 3: ...olling the overall BASIS QSControl system However the BASIS 904zz also offers a front panel interface for accessing critical functions A single QSControl server computer can support several cli ents r...

Страница 4: ...et are available at www qscontrol net We invite you to visit us there We ve applied our many years experience in supporting high end installed sound with our previous system building products such as...

Страница 5: ...ologies please visit http www qscaudio com products network resources htm and http www peakaudio com CobraNet background html Notes on Network Systems Design As with any communications system the reli...

Страница 6: ...P IP standards compliant network system and therefore supports operation on network repeaters switches and routers When implementing the Two Wire Interface the QSControl net segment does not require a...

Страница 7: ...2 connection while passing audio between them all without a network switch However you would have to physically connect your computer first to one unit and then to the other With this elementary conne...

Страница 8: ...is configuration works well when CobraNet audio deliveries are point to point Though the example shows only two units as many devices may be connected as there are available switch ports All BASIS RAV...

Страница 9: ...net traffic and a separate VLAN for CobraNet audio traffic This config uration essentially provides a dedicated network for QSControl including the system controller and a second dedicated network for...

Страница 10: ...ith its own network switch Therefore traffic segmentation is physical rather than logical Example 5 also pro vides an additional level of fault tolerance although at the expense of additional network...

Страница 11: ...r out of an equipment rack Rack mounting is optional Adhesive rubber feet are included for non rack mount installations Use them to prevent the unit from scratching or marring support surfaces Rack Mo...

Страница 12: ...used for real time adjustments and configuration of audio systems we recommend all Windows Power Options located in the Windows Control Panel features be disabled Display hard drive system standby and...

Страница 13: ...ntroller computer CobraNet Connection Loss If you are operating with a valid CobraNet network and the connection to the network is disrupted audio will momentarily mute allow ing the BASIS 904zz to sy...

Страница 14: ...evel and 0 5 VDC input The contact closure and logic devices accommodate on off or state change events the variable resistor input provides full 8 bit resolution allowing for incremental change events...

Страница 15: ...dio and ampli fier status monitoring This can be eight 2 channel amplifiers or two 8 channel amplifier or other suitable combinations If connecting a multi DataPort amplifier ensure all the DataPorts...

Страница 16: ...display are used to navigate through the menus The rotary select accept knob is active for many displayed items allowing you to scroll through choices by rotating the control and accepting choices en...

Страница 17: ...lt Boot Screen Right side buttons serve as up down navigation Arrow characters indi cate right side button context If additional menus are available the arrow character will be shown Main Menu Screens...

Страница 18: ...Client Server selection keep both Client and Server selected This will be appropriate for general use 8 When prompted Select Installation Folder specify the installation directory or accept the defaul...

Страница 19: ...nections verify IP addresses are set correctly ver ify Subnet masks are set correctly and verify AC power is properly applied to the BASIS 19 Click on the BASIS 904zz in the inventory root A view of a...

Страница 20: ...used will be copies of other channels CobraNet Channel Resolution All CobraNet audio will be processed internally within BASIS 904zz at 24 bit resolution The BASIS 904zz may receive any valid resolu t...

Страница 21: ...unicate with the BASIS 904zz if it is in safe mode You may communicate only using TFTP Telnet or RS 232 RS 232 Serial Port I O Interface The RS 232 connector on the rear panel is used as a serial port...

Страница 22: ...ick OK to continue If all the connections and communications settings are correct the main Hyper Terminal window will open 6 The Hyper Terminal main window will appear next but blank Type the letter h...

Страница 23: ...opening a Telnet session 1 To open the Telnet session Click Start select Run type Telnet followed by a space then the IP address of the BASIS 904zz you want to communicate with in the text box and cli...

Страница 24: ...utput 6 313 milliseconds 3 646 milliseconds Program Outputs 16 Connector Type 8 HD 15 dataport connections Cable Type QSC DataPort cable QSC p n DPC x x designates cable length in feet Available stock...

Страница 25: ...ts 6 discrete inputs for TTL logic voltage control or passive resistive Connector Type 2 pin Phoenix Style a k a Euro Style detachable terminal blocks Configuration Single ended ground referenced Pino...

Страница 26: ...suppliers be held liable for any damages consequential incidental or otherwise including any claims for lost profits and or savings resulting from any attempted integration of QSControl products with...

Отзывы: