18

Getting Started

This section outlines one of the simpler methods of getting familiar with your BASIS and the QSControl.net software. The goal of this 
procedure is to get your computer and the BASIS connected and communicating and the QSControl.net software installed and running. 
After the software is installed and running, refer to the software’s Help file for all software related operation/issues. Note! The default 
password for the BASIS is “qsc” (no quotes, lower case).

1-

 Turn off the computer and unplug the power cord from the BASIS 904zz.

2-

 Connect a CAT-5 crossover cable from the computer’s network interface card (NIC) to the BASIS QSControl jack (example 1, page 6).

3-

 Reconnect the power cord to the BASIS 904zz (turn it on). Using the BASIS LCD display and controls, navigate the menu to the IP 

Address and make a note of it. In steps 12 and on, you will need to change the IP address of the BASIS or your PC. 

4-

 Turn on the PC and start Windows. You must have Administrator rights and be signed on as Administrator in order to install the 

QSControl program. Ensure you are signed on to the computer as the Administrator.

5-

 Place the QSControl.net CD-ROM in your CD-ROM drive. The install wizard should start. If not, you can also select 

Start 

then 

Run

 

and browse for the file named 

setup.exe

 from the CD.

6-

 The installer queries the computer for available drive space and other information. If required MDAC library (Microsoft) files are not 

already on the computer, the library files are installed. You must accept the Microsoft software agreement in order to install the MDAC 
library. It may be necessary to reboot the computer after library installation.

7-

 At the prompt for “Client/Server” selection, keep both Client and Server selected. This will be appropriate for general use.

8- 

When prompted “Select Installation Folder”, specify the installation directory or accept the default location. 

9-

 You will be prompted to select an installation accessible by everyone (non-secure) or an installation accessible only to you (secure). 

Select the appropriate Everyone or Just Me box and continue. Installation proceeds.

10-

 Reboot only if your computer prompts you to do so.

11-

 Right click on the 

My Network Places

 icon on your computer’s desktop. Select 

Properties

. Select 

Local Area Connection

, and 

view its properties (click 

Properties

 tab). Highlight the 

Internet Protocol Properties

 tab and view its properties. You will see an 

entry field for the IP address. Decide whether you want to change the IP address of your computer to be similar that of to the BASIS 
(easiest if you have many BASIS units) or if you want to change the IP address of your BASIS to be similar to that of the computer. This 
is a network management decision.

12- 

Change the IP address of the BASIS (or computer) to be compatible with that of the computer (or BASIS). Typically, this is done by 

making the IP address of one of the devices 1 digit different in the last octet (group of digits in IP address). If changing the computer’s 
settings, write down the current values, in case you want to revert later.

13-

 The subnet mask address should be exactly the same for both the computer and the BASIS. The Gateway address should not be 

altered as it is not used.

14-

 After you are satisfied with all your settings, close all open windows and start the QSControl.net program. Select

 Start

Run,

 

QSControl.net

QSControl.net.exe

.

15-

 The login screen should open. The default password is “qsc” (lower case, no quotation marks). Select “Logon to Local Computer” 

and click OK.

16-

The QSControl.net Venue Manager window will open.

Содержание BASIS 904zz

Страница 1: ...TD 000152 00 rev A BASIS 904zz 16 Output CobraNet Enabled Control and Monitoring Signal Processor Hardware Manual TD 000152 00...

Страница 2: ...cord 5 Reliable Earthing Grounding of rack mounted equipment should be maintained LITHIUM BATTERY WARNING THIS EQUIPMENT CONTAINS A NON RECHARGEABLE LITHIUM BATTERY LITHIUM IS A CHEMICAL KNOWN TO THE...

Страница 3: ...olling the overall BASIS QSControl system However the BASIS 904zz also offers a front panel interface for accessing critical functions A single QSControl server computer can support several cli ents r...

Страница 4: ...et are available at www qscontrol net We invite you to visit us there We ve applied our many years experience in supporting high end installed sound with our previous system building products such as...

Страница 5: ...ologies please visit http www qscaudio com products network resources htm and http www peakaudio com CobraNet background html Notes on Network Systems Design As with any communications system the reli...

Страница 6: ...P IP standards compliant network system and therefore supports operation on network repeaters switches and routers When implementing the Two Wire Interface the QSControl net segment does not require a...

Страница 7: ...2 connection while passing audio between them all without a network switch However you would have to physically connect your computer first to one unit and then to the other With this elementary conne...

Страница 8: ...is configuration works well when CobraNet audio deliveries are point to point Though the example shows only two units as many devices may be connected as there are available switch ports All BASIS RAV...

Страница 9: ...net traffic and a separate VLAN for CobraNet audio traffic This config uration essentially provides a dedicated network for QSControl including the system controller and a second dedicated network for...

Страница 10: ...ith its own network switch Therefore traffic segmentation is physical rather than logical Example 5 also pro vides an additional level of fault tolerance although at the expense of additional network...

Страница 11: ...r out of an equipment rack Rack mounting is optional Adhesive rubber feet are included for non rack mount installations Use them to prevent the unit from scratching or marring support surfaces Rack Mo...

Страница 12: ...used for real time adjustments and configuration of audio systems we recommend all Windows Power Options located in the Windows Control Panel features be disabled Display hard drive system standby and...

Страница 13: ...ntroller computer CobraNet Connection Loss If you are operating with a valid CobraNet network and the connection to the network is disrupted audio will momentarily mute allow ing the BASIS 904zz to sy...

Страница 14: ...evel and 0 5 VDC input The contact closure and logic devices accommodate on off or state change events the variable resistor input provides full 8 bit resolution allowing for incremental change events...

Страница 15: ...dio and ampli fier status monitoring This can be eight 2 channel amplifiers or two 8 channel amplifier or other suitable combinations If connecting a multi DataPort amplifier ensure all the DataPorts...

Страница 16: ...display are used to navigate through the menus The rotary select accept knob is active for many displayed items allowing you to scroll through choices by rotating the control and accepting choices en...

Страница 17: ...lt Boot Screen Right side buttons serve as up down navigation Arrow characters indi cate right side button context If additional menus are available the arrow character will be shown Main Menu Screens...

Страница 18: ...Client Server selection keep both Client and Server selected This will be appropriate for general use 8 When prompted Select Installation Folder specify the installation directory or accept the defaul...

Страница 19: ...nections verify IP addresses are set correctly ver ify Subnet masks are set correctly and verify AC power is properly applied to the BASIS 19 Click on the BASIS 904zz in the inventory root A view of a...

Страница 20: ...used will be copies of other channels CobraNet Channel Resolution All CobraNet audio will be processed internally within BASIS 904zz at 24 bit resolution The BASIS 904zz may receive any valid resolu t...

Страница 21: ...unicate with the BASIS 904zz if it is in safe mode You may communicate only using TFTP Telnet or RS 232 RS 232 Serial Port I O Interface The RS 232 connector on the rear panel is used as a serial port...

Страница 22: ...ick OK to continue If all the connections and communications settings are correct the main Hyper Terminal window will open 6 The Hyper Terminal main window will appear next but blank Type the letter h...

Страница 23: ...opening a Telnet session 1 To open the Telnet session Click Start select Run type Telnet followed by a space then the IP address of the BASIS 904zz you want to communicate with in the text box and cli...

Страница 24: ...utput 6 313 milliseconds 3 646 milliseconds Program Outputs 16 Connector Type 8 HD 15 dataport connections Cable Type QSC DataPort cable QSC p n DPC x x designates cable length in feet Available stock...

Страница 25: ...ts 6 discrete inputs for TTL logic voltage control or passive resistive Connector Type 2 pin Phoenix Style a k a Euro Style detachable terminal blocks Configuration Single ended ground referenced Pino...