Third, the BASIS 904zz and QSControl.net system are targeted at network switch deployments.
The consumer costs of Ethernet switches have continued to fall over the last several years and are now comparable with repeaters on 
a per port basis. In addition, the sophistication and scalability of network switches make them ideal for new installations. However, we 
do realize that designers may wish to add BASIS products to existing audio network installations that are built on repeater LAN topolo-
gies. This applies primarily to existing CM16a and RAVE networks. For this very reason we continue to support connectivity to network 
repeater hardware with the BASIS 904zz. Support for network repeaters exist only with the Two Wire Interface. That is to say that the 
QSControl port and the CobraNet port must be connected to separate repeater LANs. Even when properly configured, audio channel 
capacity is severely limited and both audio and control network expansion is limited by the respective wire speed of each segment. In 
other words, scalability ceases to exist when bandwidth demands on the QSControl segment approach 10 Mbps and demand on the 
CobraNet segment approaches 100 Mbps. Obviously, we recommend taking advantage of switch network technology whenever possi-
ble. 

It should be noted here that while the CobraNet port on a BASIS 904zz is restricted to repeater LAN or switch LAN deployments, 
QSControl.net is a TCP/IP standards-compliant network system and therefore supports operation on network repeaters, switches and 
routers. When implementing the Two Wire Interface, the QSControl.net segment does not require a single topology data path and 
therefore repeaters, switches and routers may be assembled on the LAN in a hybrid fashion.

To learn more about network design rules and system compliance visit the QSC network resources page at http://www.qscaudio.com/
products/network/resources.htm. To learn more about CobraNet design requirements and to obtain the CobraCAD system design utility 
visit the Peak Audio website at http://www.peakaudio.com/CobraNet/Network_Design.html. 

All of this may seem daunting if you are new to networking. However, it all boils down to connecting a few simple cables between var-
ious networking devices. Most of the time it "just works". QSC helped pioneer CobraNet with our RAVE ™ products and there are hun-
dreds of installations all over the world, in theme parks, hotels, stadiums - everywhere. They run hum-free, sound great and are very 
reliable.

The following examples will help get you started, but they just scratch the surface of what can be achieved with advanced network-
ing… 

Example #1 - QSControl.net X-over mode:

This is the simplest connection you can make between the BASIS 904zz and your computer. You use a CAT-5 crossover cable connected 
between the BASIS QSControl port and your computer's Network Interface Card, (NIC). No network switch is required. With QSCon-
trol.net server and client software installed and running on your computer you will be able to completely set up and monitor your BASIS 
904zz.

Содержание BASIS 904zz

Страница 1: ...TD 000152 00 rev A BASIS 904zz 16 Output CobraNet Enabled Control and Monitoring Signal Processor Hardware Manual TD 000152 00...

Страница 2: ...cord 5 Reliable Earthing Grounding of rack mounted equipment should be maintained LITHIUM BATTERY WARNING THIS EQUIPMENT CONTAINS A NON RECHARGEABLE LITHIUM BATTERY LITHIUM IS A CHEMICAL KNOWN TO THE...

Страница 3: ...olling the overall BASIS QSControl system However the BASIS 904zz also offers a front panel interface for accessing critical functions A single QSControl server computer can support several cli ents r...

Страница 4: ...et are available at www qscontrol net We invite you to visit us there We ve applied our many years experience in supporting high end installed sound with our previous system building products such as...

Страница 5: ...ologies please visit http www qscaudio com products network resources htm and http www peakaudio com CobraNet background html Notes on Network Systems Design As with any communications system the reli...

Страница 6: ...P IP standards compliant network system and therefore supports operation on network repeaters switches and routers When implementing the Two Wire Interface the QSControl net segment does not require a...

Страница 7: ...2 connection while passing audio between them all without a network switch However you would have to physically connect your computer first to one unit and then to the other With this elementary conne...

Страница 8: ...is configuration works well when CobraNet audio deliveries are point to point Though the example shows only two units as many devices may be connected as there are available switch ports All BASIS RAV...

Страница 9: ...net traffic and a separate VLAN for CobraNet audio traffic This config uration essentially provides a dedicated network for QSControl including the system controller and a second dedicated network for...

Страница 10: ...ith its own network switch Therefore traffic segmentation is physical rather than logical Example 5 also pro vides an additional level of fault tolerance although at the expense of additional network...

Страница 11: ...r out of an equipment rack Rack mounting is optional Adhesive rubber feet are included for non rack mount installations Use them to prevent the unit from scratching or marring support surfaces Rack Mo...

Страница 12: ...used for real time adjustments and configuration of audio systems we recommend all Windows Power Options located in the Windows Control Panel features be disabled Display hard drive system standby and...

Страница 13: ...ntroller computer CobraNet Connection Loss If you are operating with a valid CobraNet network and the connection to the network is disrupted audio will momentarily mute allow ing the BASIS 904zz to sy...

Страница 14: ...evel and 0 5 VDC input The contact closure and logic devices accommodate on off or state change events the variable resistor input provides full 8 bit resolution allowing for incremental change events...

Страница 15: ...dio and ampli fier status monitoring This can be eight 2 channel amplifiers or two 8 channel amplifier or other suitable combinations If connecting a multi DataPort amplifier ensure all the DataPorts...

Страница 16: ...display are used to navigate through the menus The rotary select accept knob is active for many displayed items allowing you to scroll through choices by rotating the control and accepting choices en...

Страница 17: ...lt Boot Screen Right side buttons serve as up down navigation Arrow characters indi cate right side button context If additional menus are available the arrow character will be shown Main Menu Screens...

Страница 18: ...Client Server selection keep both Client and Server selected This will be appropriate for general use 8 When prompted Select Installation Folder specify the installation directory or accept the defaul...

Страница 19: ...nections verify IP addresses are set correctly ver ify Subnet masks are set correctly and verify AC power is properly applied to the BASIS 19 Click on the BASIS 904zz in the inventory root A view of a...

Страница 20: ...used will be copies of other channels CobraNet Channel Resolution All CobraNet audio will be processed internally within BASIS 904zz at 24 bit resolution The BASIS 904zz may receive any valid resolu t...

Страница 21: ...unicate with the BASIS 904zz if it is in safe mode You may communicate only using TFTP Telnet or RS 232 RS 232 Serial Port I O Interface The RS 232 connector on the rear panel is used as a serial port...

Страница 22: ...ick OK to continue If all the connections and communications settings are correct the main Hyper Terminal window will open 6 The Hyper Terminal main window will appear next but blank Type the letter h...

Страница 23: ...opening a Telnet session 1 To open the Telnet session Click Start select Run type Telnet followed by a space then the IP address of the BASIS 904zz you want to communicate with in the text box and cli...

Страница 24: ...utput 6 313 milliseconds 3 646 milliseconds Program Outputs 16 Connector Type 8 HD 15 dataport connections Cable Type QSC DataPort cable QSC p n DPC x x designates cable length in feet Available stock...

Страница 25: ...ts 6 discrete inputs for TTL logic voltage control or passive resistive Connector Type 2 pin Phoenix Style a k a Euro Style detachable terminal blocks Configuration Single ended ground referenced Pino...

Страница 26: ...suppliers be held liable for any damages consequential incidental or otherwise including any claims for lost profits and or savings resulting from any attempted integration of QSControl products with...