138
ERROR
VD move failed
Failed to complete move of VD <name>.
INFO
RG activated
RG <name> has been manually activated.
INFO
RG deactivated
RG <name> has been manually deactivated.
INFO
VD rewrite started
Rewrite at LBA <address> of VD <name> starts.
INFO
VD rewrite finished
Rewrite at LBA <address> of VD <name> completes.
WARNING
VD rewrite failed
Rewrite at LBA <address> of VD <name> failed.
WARNING
RG degraded
RG <name> is in degraded mode.
WARNING
VD degraded
VD <name> is in degraded mode.
ERROR
RG failed
RG <name> is failed.
ERROR
VD failed
VD <name> is failed.
ERROR
VD IO fault
I/O failure for stripe number <address> in VD <name>.
WARNING
Recoverable read
error
Recoverable read error occurred at LBA <address>-
<address> of VD <name>.
WARNING
Recoverable write
error
Recoverable write error occurred at LBA <address>-
<address> of VD <name>.
ERROR
Unrecoverable read
error
Unrecoverable read error occurred at LBA <address>-
<address> of VD <name>.
ERROR
Unrecoverable
write error
Unrecoverable write error occurred at LBA <address>-
<address> of VD <name>.
ERROR
Config read fail
Config read failed at LBA <address>-<address> of PD
<slot>.
ERROR
Config write fail
Config write failed at LBA <address>-<address> of PD
<slot>.
ERROR
CV boot error
adjust global
Failed to change size of the global cache.
INFO
CV boot global
The global cache is ok.
ERROR
CV boot error
create global
Failed to create the global cache.
INFO
PD dedicated spare
Assign PD <slot> to be the dedicated spare disk of RG
<name>.
INFO
PD global spare
Assign PD <slot> to Global Spare Disks.
WARNING
PD read error
Read error occurred at LBA <address>-<address> of PD
<slot>.
WARNING
PD write error
Write error occurred at LBA <address>-<address> of PD
<slot>.
WARNING
Scrub wrong parity
The parity/data inconsistency is found at LBA <address>-
<address> when checking parity on VD <name>.
WARNING
Scrub data
recovered
The data at LBA <address>-<address> is recovered when
checking parity on VD <name>.
WARNING
Scrub recovered
data
A recoverable read error occurred at LBA <address>-
<address> when checking parity on VD <name>.
WARNING
Scrub parity
recovered
The parity at LBA <address>-<address> is regenerated
when checking parity on VD <name>.
INFO
PD freed
PD <slot> has been freed from RG <name>.
INFO
RG imported
Configuration of RG <name> has been imported.
INFO
RG restored
Configuration of RG <name> has been restored.
INFO
VD restored
Configuration of VD <name> has been restored.
INFO
PD scrub started
PD <slot> starts disk scrubbing process.
INFO
Disk scrub finished
PD <slot> completed disk scrubbing process.
INFO
Large RG created
A large RG <name> with <number> disks included is created
INFO
Weak RG created
A RG <name> made up disks across <number> chassis is
created
INFO
RG size shrunk
The total size of RG <name> shrunk
INFO
VD erase finished
VD <name> finished erasing process.
WARNING
VD erase failed
The erasing process of VD <name> failed.
Содержание P300H61
Страница 27: ...27 Figure 2 5 2 The following topology is the connections for console and UPS optional Figure 2 5 3 ...
Страница 79: ...79 ...
Страница 110: ...110 Figure 5 7 1 2 ...
Страница 145: ...145 This form can be got from QSAN ftp ftp ftp qsan com tw QSAN_Support_Form doc ...
Страница 148: ...148 Figure B 1 3 Click Done Figure B 2 Figure B 3 ...
Страница 151: ...151 Figure B 8 Figure B 9 15 Click Add 16 Click Advanced ...
Страница 153: ...153 Figure B 14 22 Done the iSCSI device disconnect successfully ...
Страница 154: ...154 System information P300H61 P300H71 SW version 2 0 1 ...