Power Application Controller
®
-40-
Copyright 2020 © Qorvo, Inc.
Rev 1.2
– Jan 17, 2019
8.9.7
SOC.SYSCONF
Register 8-7 SOC.SYSCONF (System Configuration, 2Bh)
BIT
NAME
ACCESS
RESET
DESCRIPTION
7:3
RFU
R
0011 0b
Reserved
2
VPSET
R/W
1b
VP Output Voltage Setting.
0b: 10V
1b: 12V (default)
1
MVBB_ILIM
R/W
0b
MVBB Inductor Current Limit Range:
0b: 440mA-540mA (default)
1b: 600mA-750mA
0
CP_EN
R/W
1b
Charge Pump Enable:
0b: Disabled
1b: Enabled