Power Application Controller
®
-85-
Copyright 2020 © Qorvo, Inc.
Rev 1.2
– Jan 17, 2019
9.20.7 SOC.CFGAIO6
Register 9-7 SOC.CFGAIO6 (AIO6 Configuration, 0Ch)
BIT
IO MODE
AMPLIFIER MODE
COMPARATOR MODE
SPECIAL MODE
7:6
MODE6:
00b
MODE6:
01b
MODE6:
10b
MODE6:
11b
5
OPT6:
AIO6 IO Option:
00b: Input
01b: Hi-Z
10b: Open-drain output
11b: Hi-Z
GAIN6:
AIO6 Amplifier gain
setting:
000b: Gain amplifier bypass,
direct mode
001b: 1x
010b: 2x
011b: 4x
100b: 8x
101b: 16x
110b: 32x
111b: 48x
OPT6:
AIO6 Comparator
Reference select:
00b: VTHREF
01b: AB1
10b: AB2
11b: AB3
ADMUX:
1b: Switch ADCIN to
AB7
4
SWAP:
Buffer Swap:
0b: Do not swap buffer offset
1b: Swap buffer offset
3
POL6:
AIO6 Polarity Setting:
00b: active-high
01b: active-low
POL6:
AIO6 Comparator
output polarity setting:
0b: active-high
1b: active-low
Reserved, write as 0b
2:0
MUX6:
AIO6 Digital MUX
Setting:
000b: DATAIO6
001b: DB1
010b: DB2
011b: DB3
100b: DB4
101b: DB5
110b: DB6
111b: DB7
MUX6:
Analog MUX Setting:
000b: AB6
001b: AB1
010b: AB2
011b: AB3
100b: AB4
101b: AB5
110b: AB6
111b: AB7
MUX6:
AIO6 Digital MUX
Setting:
000b: DATAIO6
001b: DB1
010b: DB2
011b: DB3
100b: DB4
101b: DB5
110b: DB6
111b: DB7
MUX6:
Analog MUX Setting:
000b: AB6
001b: AB1
010b: AB2
011b: AB3
100b: AB4
101b: AB5
110b: AB6
111b: AB7