background image

pedestal mounted, consult pedestal kit installation instruc-
tions.

4.  Drill the required  size mounting holes in the heater housing

(See Fig. 1 for recommended mounting hole location.)

5.  Hold heater housing against the wall to check for evenness

of wall. Do not draw heater against an uneven wall surface. If
an uneven wall is encountered, use shims to keep the heater
housing straight.

6. Run proper size branch circuit to the junction box through the

selected knockout.

7. Mount the heater on the wall using screws, bolts or anchors

(by installer) to suit the wall construction.

8.  Tighten mounting screw and back off 1/2 turn to allow for

expansion and contraction of the heater.

9.  Following the wiring diagram secured to the heater, make

electrical connections. Ground the heater using the ground
screw provided. See Fig. 3.

10.Replace front cover by latching the bottom front edge of the

front cover over the bottom front edge of the back and push-
ing the cover straight back to latch the top rear edge of the
back with the top rear edge of the front cover. See Fig. 4.

Installation of Multiple Wall to Wall Units

NOTE: For ease of installation, it is important that the sequence
of operations indicated below be followed in order.

1.  Repeat Steps 1 & 2 from Single Unit Installation.

2. Refer to wiring diagram for power supply entry and remove

appropriate electrical knockout (Fig. 2) from the heater in
which power supply connections are to be made. The power
supply may be brought into the end of one heater and the
remaining heaters may be connected in parallel using the
wireway. Use Table B to size the field installed wiring in the
wireway or use Table C to determine the maximum length or
heater run possible using the factory installed wire in the
heater wireway. If units are to be pedestal mounted, consult
pedestal kit installation instructions.

3. If filler sections, inside corners, outside corners, splice kits or

end caps are to be used, consult accessory installation
instructions.

NOTE: If a heater has a disconnect switch and/or thermostat
and is to have a filler section at the left end, the filler must not
cover the access to those controls.

4. If the run of the heaters includes an inside corner or an out-

side corner, mount corner to wall (see accessory installation
instructions packed with corners), then mount heater.

5. Drill the required size mounting holes in all the heater hous-

ings. (See Fig. 1 for recommended mounting hole location.)

6. Hold heater housings against wall to check for evenness of

the wall. Do not draw the heaters against an uneven wall
surface. If an uneven wall is encountered, use shims to keep
the heater housing straight.

7. Run proper size branch circuit to the junction box through the

selected knockout.

8. Mount the heaters on the wall using screws, bolts or anchors

(by installer) which suit the wall construction. Alignment tabs
can be inserted in adjoining back housings to assure even
alignment. See Fig. 5 for details.

9. Following the wiring diagram secured to the heater, make the

electrical connections. Refer to Fig. 7  to connect the other
heaters in parallel. Grounding of the other heaters is accom-
plished by connecting a jumper wire (not supplied) between
the two adjacent heaters.

10.Replace front covers following Step 10, Single Unit

Installation (See Fig. 4.)

4

W

a

ll

Floor

Junction
Box

Ground
Screw

Run ground
wire thru top
or bottom hole.
Wrap around
ground screw
and tighten
screw.

Fig. 3

W

a

ll

Floor

Junction
Box

Ground
Screw

Run ground
wire thru top
or bottom hole.
Wrap around
ground screw
and tighten
screw.

Fig. 4

Cabinet front
cover

Putty knife or
other wide blade
tool

}

Cabinet
Back
Housing

Recommended
mounting holes
drill area

Fig. 1

Y

X

E

D

C

E

H

W

B

A

7/8” (22mm) and
1-1/8” (29mm)
concentric KO’s

1-3/8”
(35mm)
KO

7/8”
(22mm)
KO

7/8”
(22mm)
KO

1-3/8”
(35mm)
KO

1-23/32”
(44mm)
KO

Fig. 2

2” (51)

2-1/4”(28)

7/8” (22)

2-1/4”(28)
3-3/8”(86)

1-11/32”(34)

1-7/8”(48)

1-3/16”(81)
2-9/16”(28)

2-25/32” (71)

2-1/4”(28)

7/8” (22)

2-1/4”(28)
3-3/8”(86)

2” (51)

2-3/8”(60)

1-3/16”(81)
2-9/16”(28)

in. (mm)

DBA          SHA

Pedestal  placement  and
KOs shown are for standard
units.  Custom  enclosures
and/or heat decks will have
pedestal  placement  and
KOs in various locations. 
Consult factory.

A
B
C
D
E
H
W
X
Y

Содержание DBA

Страница 1: ...exhaust in any manner 5 Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage the heater 6 Serious injury or death co...

Страница 2: ...8188 188 1504 7 2 6 3 5 4 4 3 2 5 08250 250 2000 9 6 8 3 7 2 5 8 3 3 09100 100 900 4 3 3 8 3 2 2 6 1 5 09125 9 125 1125 5 4 4 7 4 1 3 2 1 9 09150 2743mm 150 1350 6 5 5 6 4 9 3 9 2 3 09188 188 1692 8 1...

Страница 3: ...SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Serious injury or death could result from electric shock Make sure electrical power supply circuit coming to heater are disconnected at main disconn...

Страница 4: ...E If a heater has a disconnect switch and or thermostat and is to have a filler section at the left end the filler must not cover the access to those controls 4 If the run of the heaters includes an i...

Страница 5: ...sure it has adequate clearances and the free airflow around heater is not restricted If heater continues to cycle on this safety control discontinue using until it can be inspected and or repaired by...

Страница 6: ...BILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS AGREEMENT MARLEY ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CO...

Страница 7: ...rico o incendio o de da os al calefactor 6 Un choque el ctrico podr a producir lesiones graves o la muerte Aseg rese de que el circuito de alimentaci n el ctrica del calefactor est desconectado en el...

Страница 8: ...4125 4 125 500 4 2 2 4 2 1 1 8 1 4 04150 1219 mm 150 600 5 0 2 9 2 5 2 2 1 7 04188 188 752 6 3 3 6 3 1 2 7 2 2 1 3 04250 250 1000 8 3 4 8 4 2 3 6 2 9 1 7 05100 100 500 4 2 2 4 2 1 1 8 1 4 0 8 05125 5...

Страница 9: ...o podr a producir lesiones graves o la muerte Aseg rese de que el circuito de alimentaci n el ctrica del calefac tor est desconectado en el tablero de servicio o desconectador principal antes de insta...

Страница 10: ...ecci n de relleno en el extremo izquierdo sta no debe cubrir el acceso a esos controles 4 Si el tramo de los calefactores incluye una esquina interior o una esquina exterior monte la esquina contra la...

Страница 11: ...de aire alrededor del calefactor no se encuentre restringida Si el calefactor contin a haciendo ciclos con este control de seguridad interrumpa su uso hasta que lo pueda inspeccionar y o reparar un el...

Страница 12: ...ODUCTS NO SE HAR RESPONSABLE POR DA OS CONSIGUIENTES QUE SE PRODUZCAN CON RESPECTO AL PRODUCTO EN BASE YA SEA A NEGLIGENCIA AGRAVIO RESPONSABILIDAD ESTRICTA O CONTRATO Algunos estados o jurisdicciones...

Страница 13: ...tincelles lectriques Ne l utilisez pas dans des zones o de l essence ou des liq uides inflammables sont utilis s 3 Ce radiateur est chaud quand il est en fonctionnement Pour viter des br lures ne lai...

Страница 14: ...Total en 208 V 240 V 277 V 347 V 600 V catalogue L par pied watts 1 Ph 3 Ph 1 Ph 3 Ph 1 Ph 1 Ph 1 Ph 3 Ph 02375 375 750 3 6 3 1 2 7 02500 28 500 1000 4 8 4 2 3 6 2 9 02600 711 mm 600 1200 5 8 3 3 5 0...

Страница 15: ...ESSURES AUX PERSONNES OBSERVEZ LES CONSIGNES SUIVANTES 1 Une blessure s rieuse voire mortelle peut r sulter d une commo tion lectrique Assurez vous que le circuit du secteur d alimenta tion lectrique...

Страница 16: ...mit de gauche cette section ne doit pas couvrir l acc s ces commandes 4 Si l ensemble des radiateurs comprend un angle rentrant ou saillant montez d abord cet angle sur la cloison voyez les instructi...

Страница 17: ...s par le dispositif de s curit cessez de l utiliser avant qu il ait t inspect et ou r par par un lectricien qualifi INSTRUCTIONS D ENTRETIEN Votre radiateur vous fournira des ann es de bon service et...

Страница 18: ...s frais de main d uvre et les frais de port encourus pour retourner le produit au centre de r paration de la soci t Marley Engineered Products Sous r serve des restrictions figurant dans cette garanti...

Отзывы: