3–Interactive Commands
Utilities Menu
SN0054614-00 K
3-67
Maximum LUNs Per Target
specifies the maximum number of LUNs per
target. Multiple LUN support is typically for RAID boxes that use LUNs to
map drives.
Port Down Retry Count
specifies the number of times SANsurfer FC/CNA
HBA CLI retries a command to a port returning port down status.
Link Down Timeout
specifies the time the driver waits for the link to come
up after link down before returning the I/Os. This is analogous to the
Port
Down Retry Count
setting, which is used when the port is down.
The following tables list the parameter settings supported by templates for the
specified adapters by ISP number.
NOTE:
Settings that are effected by the template apply only to the ISP
2300/2310/2312 2Gb adapters and the ISP2422/2432 4Gb adapters.
Table 3-5. Template Supported Parameter Settings for QLA24xx/QLE24xx and QLE256x
Adapters (ISP2422)
Setting
QLogic
EMC
HP
IBM
Sun
Execution Throttle
16
256
16
256
256
Descending Loop ID Search
0
0
0
0
0
Maximum LUNs Per Target
*
a
a
Information not currently available.
256
128
256
128
Port Down Retry Count
30
45
16
30
30
Link Down Timeout
30
45
8
30
30
Table 3-6. Template Supported Parameter Settings for QLA24xx/QLE24xx and QLE256x
Adapters (ISP2432)
Setting
QLogic
Dell
EMC
HP
IBM
Sun
Execution Throttle
16
256
256
16
256
16
Descending Loop ID
Search
0
1
1
0
0
0
Maximum LUNs Per Target
128
256
256
128
256
128
Port Down Retry Count
30
45
45
16
30
30
Link Down Timeout
30
45
45
8
30
30
Содержание SANsurfer FC/CNA HBA CLI
Страница 174: ...3 Interactive Commands Help Menu Command Line Option h 3 122 SN0054614 00 K Notes ...
Страница 224: ...4 Non Interactive Commands Command Summary 4 50 SN0054614 00 K Notes ...
Страница 256: ...A XML Format 1 XML Format 1 Tags for Each Option A 32 SN0054614 00 K Notes ...
Страница 292: ...B XML Format 2 XML Format 2 Tags for Each Option B 36 SN0054614 00 K Notes ...
Страница 322: ...D Help Commands D 10 SN0054614 00 K Notes ...