UG-1084
ePAQ-9405
User’s Guide
Copyright © 2017 QEI
Switches
5
FRONT PANEL LABEL
POWER
Turns the ePAQ on and off
I = Power on
O = Power off
L / R
Local/Remote switch. When in Local mode, relay operation is
disabled.
I = Remote
O = Local (L/R Led will be on, indicating local mode)
FUSE
48/125V Input = 1 Amp Slo-Blo 250VAC (QEIP/N 10-003669-001)
12/24V Input = 2 Amp Slo-Blo 250VAC (QEIP/N 10-003669-026)
4.2 Dip Switches
One bank of four DIP switches is available through the front panel. Dip switches are
used for application specific options (see the appropriate
ConfigWiz 2.0
addendum
for further information). The exception is switch 1, which is used for safe boot mode.
OPTIONS
FRONT PANEL LABEL
Options
Dip switch bank of 4 switches.
Switch 1 = UP = Safe Mode Boot on power cycle as follows:
Ethernet IP default set to 100BaseT port (J7).
IP Address = 192.168.1.199
Passwords disabled.
Servers and Clients disabled.
Note: Configuration tables are not erased in Safe Mode Boot.
Tables can still be read or written.
Swtches 2 thru 4 = future use.