3.

 

Then  switch  your  primary  controller  to  “exclusion  mode”  to  remove  your 
MyKey from network. Please consult the relevant controller’s manual on how 
to reach “exclusion mode”; 

4.

 

Your  MyKey  lights  green  for  2  seconds  and  is  subsequently  removed  from 
your existing Z-Wave network.

 

 
Inclusion in Z-Wave network &  
Association of new products to controller groups 
 

In  order  to  remotely  control  any  device  you  need  to  include  it  into  your  wireless  Z-
Wave network and associate it to one of the MyKey groups. Please take note that each 
group is mapped to a button (e.g. group 1 is mapped to button 1, group 2 is mapped to 
button 2, etc.)  
 

1.

 

Press  3  times  quickly  on  the  button  that  you  want  to  use  for  controlling  your 
device (the LED lights blue) 

2.

 

Then press 3 times quickly on the 

QEES

 device you want to control – 

QEES

 

device lights purple and it will begin linking.  

3.

 

After  successful  linking  between  the  MyKey  and  the  device,  both  LEDs  will 
glow green for 2 seconds. 

4.

 

To assign more than one device to  one  button just  make sure that  you  follow 
the same steps as above. 

5.

 

After  the  linking  is  finished  the  device(s)  can  be  controlled  wirelessly  from 
your MyKey button. A single press will turn your product on or off. Keep the 
button pressed down to adjust the light intensity (only for Z-Wave dimmers). 

6.

 

By  repeating steps 1-3  you can add multiple devices  to  other buttons  on your 
MyKey. 

 
For non-

QEES

 devices the MyKey behavior is the same. You need to put  your non-

QEES device in learn mode and for this please refer to their manual for the procedure 
“Activating Z-Wave Learn Mode”. 
 
Note: If MyKey is acting as a secondary controller in the Z-Wave network then it can 
not include other Z-Wave devices.  In this case triple pressing one of the buttons will 
only perform the association process described below. 

 
 
Association of existing products to your MyKey groups 

Here we have the same 3 steps that we used for association of new devices to group

 

1.

 

Press 3 times quickly on the button you want to use to control the device;  

2.

 

Then  press  3  times  quickly  on  the  device  which  is  already  added  to  the 
network-the device lights purple and it begins linking; 

3.

 

After successful linking between MyKey and the device, both LEDs will glow 
green for 2 seconds; 

4.

 

The device can now be controlled wirelessly from your MyKey; 

5.

 

For  non-

QEES

  products  please  refer  to  their  manual  at  the  section  “Network 

Inclusion” in order to complete the inclusion process. 

 

Содержание MyKey

Страница 1: ...0 QEES A S Naverland 2 14 sal 2600 Glostrup Denmark 45 81 41 10 10 www qees eu QEES MyKey Online Manual ...

Страница 2: ...ew products to controller groups 6 Associating existing products to your MyKey 6 Exclusion of a device from network 7 Creating one way link between products 7 Deleting a link between MyKey and a device 7 Controlling devices 8 Activating Scenes 8 Controller Shift Replication 8 Resetting MyKey 9 Bridge Mode 9 Software Update 9 Interoperability and Certification 10 Supported Z Wave Command Classes 10...

Страница 3: ...battery included with standard USB Charger not included Strap Key ring feature 4 different Association Groups each mapped on a button eg button 1 group 1 button 2 group 2 etc and each supporting up to 148 associations Battery Specification Li ion Battery 3 7V 160 mA up to 1 month for normal use rechargeable Temperature Limits Operating Temperature 20 Celsius to 50 Celsius Charging QEES MyKey is re...

Страница 4: ...lection Point To get to the menu selection point you need to hold pressed any two buttons on your QEES MyKey You know that you have reached the menu selection point if you see white LED feedback Here you can cycle through all the menu options by clicking on button 3 for cycle up and button 4 for cycle down note each click will show a different color representing a different menu 1 Purple Scene Man...

Страница 5: ...Key to from your network you go to this menu and select the action that you need To activate the Blue Menu go to Menu Selection Point and click your way to the blue option Once you have reached the blue option press button 2 to access the Blue Menu At this point you have reached the Action Selection Point and the LED feedback you get is blue along with another color the action color usually cyan f...

Страница 6: ...r wireless network around it Inclusion of MyKey to existing Z Wave networks If you just bought MyKey but you already have a Z Wave wireless network built around another controller then you will want to include the device to the existing network The steps that must be followed in order to do this are 1 Go to the Menu Selection Point 2 Select the Blue Menu and choose the yellow option in order to pu...

Страница 7: ...ng is finished the device s can be controlled wirelessly from your MyKey button A single press will turn your product on or off Keep the button pressed down to adjust the light intensity only for Z Wave dimmers 6 By repeating steps 1 3 you can add multiple devices to other buttons on your MyKey For non QEES devices the MyKey behavior is the same You need to put your non QEES device in learn mode a...

Страница 8: ...n menu on your MyKey and select the purple option 2 Press 3 times quickly on the QEES device to be linked as a slave unit the MyKey LED lights green the device will send a Node Information Frame 3 Then press 3 times quickly on the QEES device to be linked as the controlling device the MyKey LED flashes green the device will send a Node Information Frame 4 Your one way link has been created Now pre...

Страница 9: ...sfer its primary role to a secondary controller from the same network After the transfer takes place MyKey will become a secondary controller and will lose its capability of including other nodes in the network In order to initiate the controller shift procedure you need to follow the steps below 1 on the MyKey go to the Blue Menu and select the Green option 2 on the secondary controller initiate ...

Страница 10: ...an be used with a PC software application called QEES PC Controller You can exit Bridge Mode and return to Controller Mode by pressing any button The device will automatically go back to the Bridge Mode after 60 seconds of inactivity Software Update As all other QEES devices QEES MyKey can be upgraded with new features when a new firmware is released In order to do this you must follow the next se...

Страница 11: ...be available in a future software release Scene Command Classes Implementation The controller works with both scenes and groups QEES Switches and Dimmers can perform various scenarios scenes that were configured on them In Z Wave terminology this makes them a type of Scene Actuator and the scenes are configured using the Scene Actuator Configuration Command Class The MyKey can send them a command ...

Страница 12: ...ct as a repeater Try moving closer to a Z Wave device and enable network wide inclusion on the device that you want to add in the network The Z Wave device has to be in inclusion mode in order to be added Try using the steps you find in the manual at chapter Adding devices to network MyKey may not have inclusion privileges Make sure the device is primary controller see the manual for steps require...

Страница 13: ...g defects and comply with the specifications in the manual The devices not complying with the above facts will be repaired replaced or refunded by QEES only if the products have not been subject to faulty use improper installation or abuse Defective products during warranty period have to be shipped along with dated proof of purchase to QEES A S Kultorvet 9 kl 1175 Kobenhavn Denmark QEES is in no ...

Страница 14: ... 2600 Glostrup Denmark 45 81 41 10 10 www qees eu QEES Terminology Z Wave Terminology Add device to network Inclusion Process Remove device from network Exclusion Process Controller Shift Controller Change and Controller Replication ...

Отзывы: