4.

 

During the  controller shift  procedure MyKey will  attempt to  replicate any 
application  data  (groups)  transferred  by  the  primary  controller  using  the 
Controller Replication Command Class. 

Note: 

During the controller replication procedure MyKey will accept only 

group  information  from  the  primary  controller.  It  will  ignore  the  scene 
information  transferred  by  the  primary  controller.  Accepting  also  scene 
information will be available in a future software release. 

 
 

Resetting MyKey 

You can 

reset default settings

 on your 

QEES

 MyKey by going in the Blue Menu and 

selecting  the  purple  option.  This  procedure  will  delete  all  associations  and  scenes 
made on MyKey. 
 
Another type of reset  is  the 

Hardware  Reset

  and it can be done by keeping pressed 

down for approximately 40 seconds button 4 of your MyKey. This procedure will reset 
the  device  if  it  behaves  erratically  or  does  not  respond  to  actions  keeping  the 
associations and scenarios made on MyKey. 
 

Bridge Mode 

When plugged into the USB port MyKey goes into the Bridge Mode State. In this state 
the  device  will  expose  a  serial  port  interface  to  the  PC  and  can  be  used  with  a  PC 
software application called QEES PC Controller. 
You can exit Bridge Mode and return to Controller Mode by pressing any button. The 
device will automatically go back to the Bridge Mode after 60 seconds of inactivity. 

 
Software Update 

As all other 

QEES

 devices 

QEES

 MyKey can be upgraded with new features when a 

new  firmware  is  released.  In  order  to  do  this  you  must  follow  the  next  sequence  of 
steps: 

1.

 

Connect  your MyKey to the computer through a USB port. Depending on the 
operating  system  you  will  either  be  asked  to  install  a  driver  for  this  device 
automatically or you will need to do it manually; 

2.

 

Install  QEES  PC  Controller software freely provided by 

QEES

  (you can  find 

the installer and the installation instructions on 

www.

QEES

.eu

); 

3.

 

Put your MyKey in USB Update mode by pressing down any two buttons 
while the device is making one of the charging-related feedbacks (charging or 
charged). The LED will light solid green once in USB Update mode; 

4.

 

Refer to the QEES PC Controller documentation on how to upload the new 
firmware image on MyKey. 

 
Interoperability and Certification 

All QEES Z-Wave devices are Z-Wave Certified. This guarantees that QEES Z-Wave 
devices  will  be  interoperable  in  a  network  with  other  third  party  Z-Wave  Certified 
devices.  Every  mains  powered  device  can  be  used  as  a  repeater  inside  a  Z-Wave 
network. 
 

Supported CCs:  

 

Basic Command Class 

Содержание MyKey

Страница 1: ...0 QEES A S Naverland 2 14 sal 2600 Glostrup Denmark 45 81 41 10 10 www qees eu QEES MyKey Online Manual ...

Страница 2: ...ew products to controller groups 6 Associating existing products to your MyKey 6 Exclusion of a device from network 7 Creating one way link between products 7 Deleting a link between MyKey and a device 7 Controlling devices 8 Activating Scenes 8 Controller Shift Replication 8 Resetting MyKey 9 Bridge Mode 9 Software Update 9 Interoperability and Certification 10 Supported Z Wave Command Classes 10...

Страница 3: ...battery included with standard USB Charger not included Strap Key ring feature 4 different Association Groups each mapped on a button eg button 1 group 1 button 2 group 2 etc and each supporting up to 148 associations Battery Specification Li ion Battery 3 7V 160 mA up to 1 month for normal use rechargeable Temperature Limits Operating Temperature 20 Celsius to 50 Celsius Charging QEES MyKey is re...

Страница 4: ...lection Point To get to the menu selection point you need to hold pressed any two buttons on your QEES MyKey You know that you have reached the menu selection point if you see white LED feedback Here you can cycle through all the menu options by clicking on button 3 for cycle up and button 4 for cycle down note each click will show a different color representing a different menu 1 Purple Scene Man...

Страница 5: ...Key to from your network you go to this menu and select the action that you need To activate the Blue Menu go to Menu Selection Point and click your way to the blue option Once you have reached the blue option press button 2 to access the Blue Menu At this point you have reached the Action Selection Point and the LED feedback you get is blue along with another color the action color usually cyan f...

Страница 6: ...r wireless network around it Inclusion of MyKey to existing Z Wave networks If you just bought MyKey but you already have a Z Wave wireless network built around another controller then you will want to include the device to the existing network The steps that must be followed in order to do this are 1 Go to the Menu Selection Point 2 Select the Blue Menu and choose the yellow option in order to pu...

Страница 7: ...ng is finished the device s can be controlled wirelessly from your MyKey button A single press will turn your product on or off Keep the button pressed down to adjust the light intensity only for Z Wave dimmers 6 By repeating steps 1 3 you can add multiple devices to other buttons on your MyKey For non QEES devices the MyKey behavior is the same You need to put your non QEES device in learn mode a...

Страница 8: ...n menu on your MyKey and select the purple option 2 Press 3 times quickly on the QEES device to be linked as a slave unit the MyKey LED lights green the device will send a Node Information Frame 3 Then press 3 times quickly on the QEES device to be linked as the controlling device the MyKey LED flashes green the device will send a Node Information Frame 4 Your one way link has been created Now pre...

Страница 9: ...sfer its primary role to a secondary controller from the same network After the transfer takes place MyKey will become a secondary controller and will lose its capability of including other nodes in the network In order to initiate the controller shift procedure you need to follow the steps below 1 on the MyKey go to the Blue Menu and select the Green option 2 on the secondary controller initiate ...

Страница 10: ...an be used with a PC software application called QEES PC Controller You can exit Bridge Mode and return to Controller Mode by pressing any button The device will automatically go back to the Bridge Mode after 60 seconds of inactivity Software Update As all other QEES devices QEES MyKey can be upgraded with new features when a new firmware is released In order to do this you must follow the next se...

Страница 11: ...be available in a future software release Scene Command Classes Implementation The controller works with both scenes and groups QEES Switches and Dimmers can perform various scenarios scenes that were configured on them In Z Wave terminology this makes them a type of Scene Actuator and the scenes are configured using the Scene Actuator Configuration Command Class The MyKey can send them a command ...

Страница 12: ...ct as a repeater Try moving closer to a Z Wave device and enable network wide inclusion on the device that you want to add in the network The Z Wave device has to be in inclusion mode in order to be added Try using the steps you find in the manual at chapter Adding devices to network MyKey may not have inclusion privileges Make sure the device is primary controller see the manual for steps require...

Страница 13: ...g defects and comply with the specifications in the manual The devices not complying with the above facts will be repaired replaced or refunded by QEES only if the products have not been subject to faulty use improper installation or abuse Defective products during warranty period have to be shipped along with dated proof of purchase to QEES A S Kultorvet 9 kl 1175 Kobenhavn Denmark QEES is in no ...

Страница 14: ... 2600 Glostrup Denmark 45 81 41 10 10 www qees eu QEES Terminology Z Wave Terminology Add device to network Inclusion Process Remove device from network Exclusion Process Controller Shift Controller Change and Controller Replication ...