INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.TRON (BLK) M-G2.X
10
Mounting options with bolts
The illustrated installation options apply for both horizontal and vertical module orientation.
Module
Bolt
Mounting rail
4 BOLTS / SCREWS ON LONG SIDE &
2 CONTINUOUS RAILS PARALLEL TO SHORT SIDE
4 BOLTS / SCREWS ON LONG SIDE &
2 CONTINUOUS RAILS UNDERNEATH LONG FRAME PARTS
FB1
EN
FB1
L
FB2
EN
FB2
L
POSITION OF
BOLTS [mm]
TEST LOAD
PUSH / PULL [Pa]
DESIGN LOAD
PUSH / PULL [Pa]
POSITION OF
BOLTS [mm]
TEST LOAD
PUSH / PULL [Pa]
DESIGN LOAD
PUSH / PULL [Pa]
L
371
5400 / 3600
3600 / 2400
L
371
3700 / 3600
2460 / 2400
FB1, FB2
Ensure that module frame is fixed directly on the rail of the substructure (no spacer allowed between the
module and substructure).
Use M8 corrosion-proof screws and washers (diameter ≥ 15.8 mm) for mounting slots (Detail A, Fig.1).
Mounting screws and washers should have the same material properties.
FB2
Minimum support depth of 15 mm is required on the back side of the module.
Mounting options with insertion profiles
The illustrated installation options apply for both horizontal and vertical module orientation.
Module
Profile
INSERTION PROFILE ON LONG SIDE
INSERTION PROFILE ON SHORT SIDE
IP1
IP1
IP2
IP1
IP2
IP2
IP1
IP2
IP1
IP2
TEST LOAD
PUSH / PULL [Pa]
DESIGN LOAD
PUSH / PULL [Pa]
TEST LOAD
PUSH / PULL [Pa]
DESIGN LOAD
PUSH / PULL [Pa]
3600 / 3300
2400 / 2200
2400 / 2000
1600 / 1330
IP1, IP2
Ensure minimum support depth of 15 mm on the backside and 10 mm on the front side of the module.
2 Planning
2.3 Mounting options