INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.TRON (BLK) M-G2.X
8
2 Planning
2.3 Mounting options
4 CLAMPS ON SHORT SIDE &
2 CONTINUOUS RAILS PARALLEL TO LONG SIDE
4 CLAMPS ON SHORT SIDE
CL2a
CL2a
CL2b
S
S
S
S
CL2b
CL2a
CL2b
S
S
S
S
POSITION OF
CLAMPS* [mm]
TEST LOAD
PUSH / PULL [Pa]
DESIGN LOAD
PUSH / PULL [Pa]
POSITION OF
CLAMPS* [mm]
TEST LOAD
PUSH / PULL [Pa]
DESIGN LOAD
PUSH / PULL [Pa]
S
20 - 130**
3600 / 2400
2400 / 1600
S
20 - 200
2400 / 2400
1600 / 1600
20 - 350**
3600 / 2000
2400 / 1330
CL2a
Ensure that module frame is fixed directly on the rail of the substructure (no spacer allowed between the
module and substructure).
CL2b
Minimum support depth of 15 mm is required on the back side of the module.
Short mounting rails are permissible, if they overlap with the module less than 110 mm. Maintain a minimum
distance (clearance) of ≥ 70 mm between frame bottom edge and roof top or ballast.
4 CLAMPS ON LONG SIDE &
2 CONTINUOUS RAILS UNDERNEATH LONG FRAME PARTS
2 CLAMPS ON LONG SIDE, 2 CLAMPS ON SHORT SIDE
CL3
CL3
CL4
300 - 550
0 - 300
0 - 300
CL3
CL4
CL4
0 - 200
ROW
CL3
300 - 550
L
CL5
EUROPE
CL5
L
S
POSITION OF
CLAMPS* [mm]
TEST LOAD
PUSH / PULL [Pa]
DESIGN LOAD
PUSH / PULL [Pa]
POSITION OF
CLAMPS* [mm]
TEST LOAD
PUSH / PULL [Pa]
DESIGN LOAD
PUSH / PULL [Pa]
L
200 - 350
4000 / 3600
2660 / 2400
S
20 - 100
3200 / 3200
2130 / 2130
L
300 - 450
CL3
Ensure that module frame is fixed directly on the rail of the substructure (no spacer allowed between the
module and substructure).
Minimum support depth of 15 mm is required on the back side of the module.
CL5
Minimum required support depth on the module backside is 10 mm on long frame side and 15 mm on short
frame side.
*
**
Distance between outer edge of module and middle of the clamp.
Rails must not be under the junction box.