background image

INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.TRON(BLK) M-G2.X

3

1 Introduction

With solar modules from Hanwha Q CELLS GmbH (hereafter 

referred to as "Qcells") you can directly transform the sun’s 

limitless energy into environmentally-friendly solar electricity. 

In order to ensure the maximum performance of your Qcells 

solar modules, please read the following instructions carefully 

and observe all guidelines. Non-compliance may result in 

damage and / or physical injury.

This installation and operation manual (hereafter also referred to 

as the “Manual”) provides instructions for the safe installation and 

operation of crystalline solar modules.

  Please read these instructions carefully before proceeding with 

your installation.

  Please retain these instructions for the life of the solar modules.

  Please ensure that this Manual is available to the operator at all 

times.

  This Manual should be given to all subsequent owners or users 

of the solar modules.

  All supplements received from the manufacturer should be 

included.

  Please observe all other applicable documents.

  If your questions are not satisfactorily answered in the manual, 

please contact your system supplier.

Additional information can be found on our website at www.

qcells.com.

Intended use

This manual is valid for Africa, Asia, Europe, Latin America, South 

America. These instructions contain information regarding the 

safe handling and use of quality crystalline solar modules from 

Qcells and their installation, mounting, wiring, maintenance and 

disposal.

Symbols and Labels

The following symbols and labels are used throughout the 

Manual for ease of use.

SYMBOL

DESCRIPTION

Procedure with one or more steps.
Lists of items.
Ensure that when carrying out a procedure,

you check the results of said procedure.
Prohibited.

Beware of possible danger or damage.  

Categories:

 

Danger: Risk of fatal injury

 

Attention: Risk of serious injury or damage to 
property

 

Note: Risk of damage to product

Safety Regulations

In particular the installer as well as the operator of a module is 

responsible for compliance with all applicable statutory require-

ments and regulations.

  Unless otherwise specified by any laws or regulations, the 

following stipulations must be upheld at all times during the 

installation, operation, and maintenance of the solar modules:

 

This manual.

 

Other applicable stipulations (such as country-specific regu-

lations for pressure equipment, operational safety, hazard-

ous goods, and environmental protection).

 

Regulations and requirements specific to the system.

 

Any applicable laws and requirements, in particular inter-

national, country specific, regional laws and stipulations 

governing the planning, installation, and operation of solar 

power systems and work on roofs.

 

Any valid international, national and regional regulations 

governing work with direct current, especially those appli-

cable to the installation of electrical devices and systems, 

and regulations issued by the respective energy provider 

governing the parallel operation of solar power systems.

 

Any international, country specific and regional acci-

dent-prevention regulations.

 

Other applicable stipulations provided by the relevant 

national institutions regarding safety in the installation and 

operation of electrical items.

Qualified and Skilled Personnel

Both, the installer and operator are responsible for ensuring that 

the installation (including connection to the grid), maintenance 

and dismantling are carried out by trained and qualified special-

ists with approved training certificates (issued by a state or 

federal organization) for the respective specialist trade. Electrical 

work may only be performed by an officially certified tradesper-

son in accordance with the stipulations applicable in the relevant 

country with regard to standard and regulations (in Germany e. g. 

DIN standards, VDE regulations) and the stipulations of the local 

grid operator and / or energy provider. 

Содержание Q.TRON M-G2.X Series

Страница 1: ...Installation and operation manual Q TRON BLK M G2 X solar module series...

Страница 2: ...e was manufactured apply to the installation mounting and maintenance procedures for the respective solar modules as far as no updated document is provided 1 Introduction 3 2 Planning 5 2 1 Technical...

Страница 3: ...Attention Risk of serious injury or damage to property Note Risk of damage to product Safety Regulations In particular the installer as well as the operator of a module is responsible for compliance w...

Страница 4: ...em supplier for information concerning the formal requirements for solar power systems Please be sure to contact the relevant local authorities and energy providers regarding regulations and permit re...

Страница 5: ...tection class IP67 with bypass diode Connector protection class IP68 Fire rating based on ANSI UL 61730 C Type 2 Max test load Push Pull1 8 100Pa 4 000Pa Max design load Push Pull1 5 400Pa 2 660Pa Cer...

Страница 6: ...uch as buildings chimneys or trees Avoid partial shading for example through overhead lines dirt snow Mounting Structure Requirements The Modules shall be installed and operated on mounting struc ture...

Страница 7: ...ed by technical measures Loads according to IEC 61215 2 2016 and UL 61730 2 2017 except for design loads lower than 1600 Pa which do not fulfill the requirements of the standards The test procedure is...

Страница 8: ...s than 110mm Maintain a minimum distance clearance of 70mm between frame bottom edge and roof top or ballast 4 CLAMPS ON LONG SIDE 2 CONTINUOUS RAILS UNDERNEATH LONG FRAME PARTS 2 CLAMPS ON LONG SIDE...

Страница 9: ...ructure CL6c Short mounting rails are permissible if they overlap with the module less than 110mm Maintain a minimum distance clearance of 40mm between frame bottom edge and roof top or ballast Minimu...

Страница 10: ...il of the substructure no spacer allowed between the module and substructure Use M8 corrosion proof screws and washers diameter 15 8mm for mounting slots Detail A Fig 1 Mounting screws and washers sho...

Страница 11: ...nstalled Take into account all possible operating situations and all relevant technical norms and regulations when designing the system It has to be ensured that the maximum system voltage including a...

Страница 12: ...act the transport company regarding any damage to the packaging and follow their instructions Follow any instructions on the packaging Ensure that all personnel are aware of and adhere to accident pre...

Страница 13: ...ioning systems Note Module damage may occur Do not drop modules Note Module damage may occur Only make modifications to the module which have been confirmed in writing by Qcells confirmation letter No...

Страница 14: ...fatal injury due to electric shock Ensure that modules and tools are not subject to moisture or rain at any time during installation Warning Risk of injury due to falling modules Secure modules during...

Страница 15: ...interval of at least 10mm between two modules along the short side and 5mm along the long side 10 mm 5 m m EU Note Module damage may occur Do not subject modules to mechanical tension Max torsion 10m...

Страница 16: ...safety guide lines for the installation of electrical devices and systems Please make sure to take all necessary safety precautions With module or phase voltages of more than 120V the safety extra low...

Страница 17: ...of fatal injury due to electric shock Never plug or unplug the cable when under load Modules must not carry any current 1 Switch off the inverter OFF EN 2 Switch off the DC circuit breaker 3 Measure s...

Страница 18: ...nections Note Module damage may occur Ensure that the cabling is not under mechanical stress Comply with bending radius of 60mm Ensure that the cables do not run between module and mounting rail or st...

Страница 19: ...ds Note Module damage may occur Ensure that the plug connections are secured away from any water channelling surface Integrate the system into the existing lightening protection system in accordance w...

Страница 20: ...cts Danger Risk of fatal injury due to electric shock Do not attempt to fix any problems yourself e g glass cracks damaged cables Please contact an installer or Qcells Technical Customer Service Depar...

Страница 21: ...y without force e g with a very soft broom Do not scratch off dirt Module cleaning has to be done by qualified personnel according to the state of the art and taking into account all rele vant safety...

Страница 22: ...tion manual solar modules Q TRON_M G2 X_modules_series_2023 07_Rev02_EN Hanwha Q CELLS GmbH OT Thalheim Sonnenallee 17 21 06766 Bitterfeld Wolfen Germany EMAIL WEB TEL FAX sales qcells com www qcells...

Отзывы: