WEB OPERATION
QC40198/QC40196 User Manual
103 |
P a g e
Please refer to the following chart for detailed information:
Parameter Function
Event
Type
There are three types: Motion detection/video loss/Camera Masking.
Channel
Select channel name from the dropdown list.
Enable
You need to put a checkmark to enable motion detection function.
Sensitivity There are six levels. The sixth level has the highest sensitivity.
Region
Region: If you select motion detection type, you can click this button
to set motion detection zone. The interface is shown in
X469H 469H469H
Figure 7-41
X
.
There are PAL 22X18/NTSC 22X15 zones. Right click mouse you can
go to full-screen display mode. Click OK button to save your motion
detection zone setup.
Period
Motion detection function becomes activated in the specified periods.
There are six periods in one day. Put a checkmark to enable
corresponding period.
Select date. If you do not select, current setup applies to today only.
You can select all week column to apply to the whole week.
Click OK button, system goes back to motion detection interface;
please click save button to exit.
Anti-dither System only memorizes one event during the anti-dither period. The
value ranges from 0s to 15s.
Normal
out
There is 2-channel alarm output.
Corresponding to motion detection alarm output port (multiple
choices)
Enable alarm activation function. You need to select alarm output port
so that system can activate corresponding alarm device when alarm
occurs.
Alarm
latch
System can delay the alarm output for specified time after alarm ends.
The value ranges from 10s to 300s.
Alarm
upload
System can upload the alarm signal to the centre (Including alarm
centre.
Record
channel
System auto activates motion detection channel (multiple choices) to
record once alarm occurs (working with motion detection function).
Please note current device shall be in alarm record period (Chapter
7.3.2.3 Schedule) and you have enabled the schedule record function
in chapter 7.3.3.3 Record.
Record
latch
System can delay the record for specified time after alarm ends. The
value ranges from 10s to 300s.
If you enabled this function, System can send out an email to alert you
when alarm occurs and ends.