INSTALLATION AND OPERATION MANUAL FOR CIGS SOLAR MODULES Q-CELLS SE - EUROPE

7 CLEANING AND MAINTENANCE

Q.CELLS  CIGS  modules  are  built  to  last  and  require  minimal  maintenance.    Light  dirt  is 
typically washed away by rain. However, rain may not adequately clear more stubborn grime 
(i.e. pollen, vegetation, bird droppings, etc.). Such soiling which shades the active area of the 
module can lead to a reduction in the system‘s performance.

WARNING! Danger of injury from heated and live modules!
Only clean the modules when the module temperature lies between 10 °C and 30 °C, e.g. in 
the early morning or late evening. Do not wear electrically conductive parts. Don’t clean dam-
aged modules. This can cause an electric shock.

WARNING! Risk of falling during maintenance of roof installations and building-integrated installations!
Never enter the installation area alone and unsecured. We recommend commissioning a spe-
cialist company to perform this work. Consult your installer on location.

As the operator, you should regularly remove dirt built up from the modules. In addition to the 
safety instructions and chapter 3, observe the following points:

• Never step on the modules. Do not subject the modules to mechanical stress.
• Avoid cleaning with water when there is a danger of frost and strong temperature  

 

differences between the module, water and air.

• Hard water used as a cleaning agent should be decalcified beforehand in order to avoid 

water staining.  Remove any standing water from the module.

• Do not use abrasive detergents or surface-active agents (e.g. soap). Do not scratch dirt off. 

This can damage the surface of the module. 

Modules must not be covered by snow or ice for a longer period.
Only remove snow and ice without exerting force (e.g. with a broom).
Proceed as follows to remove dirt from the 

top of the module

:

1.  Rinse coarse dirt (dust, leaves, etc.) from the module with lukewarm water.
2.  Moisten stubborn stains and remove them carefully. 
Use lukewarm water and a soft cloth or sponge. Don’t put the modules under water. If neces-

If neces-

sary, it is possible to use isopropanol (IPA) 

selectively

. Follow the safety instructions on the 

IPA packaging. Ensure that the IPA does not run off between the module and the frame or into 
the module edges. 

Free the 

substructure

 of dirt (leaves, bird nests, etc.). In the case of ground-mounted instal-

lations, we recommend regularly trimming of the vegetation order to avoid partial shading. Be 
sure to pay attention to the cables and stones.

The solar system should be inspected annually by a specialist installer for:

• secure fastening and corrosion-free system components
• secure connection, cleanliness and integrity of all electrical components
• the contact resistances of the grounding.

Do  not  decommission  the  module  on  your  own.  Commission  a  specialist  company  for  this 
purpose. Q.CELLS is a member of the European PV Cycle Association and accepts our product 
responsibility. You can give back modules of Q-Cells SE and allow them to be processed within 
the PV Cycle member states. More information can be found at www.pvcycle.com.

SAFETY INSTRUCTIONS

CLEANING

MAINTENANCE

8 DECOMMISSIONING AND RECYCLING

Содержание Q.SMART Series

Страница 1: ...Q SMART Installation and operation manual for Q SMART Q SMART UF Q SMART UF L Generation G1 3 CIGS SOLAR MODULES Valid for Europe...

Страница 2: ...CYCLING PAGE 16 9 CONTACT PAGE 17 10 APPENDIX APPLICATION NOTE GROUNDING PAGE 18 Technical parameters and design are subject to change The data sheets and customer information valid at the point in ti...

Страница 3: ...nstructions please first contact your system supplier You can find more information at our website www q cells com Q CELLS CIGS solar modules allow you to directly transform the unlimited energy provi...

Страница 4: ...erating Manual by Q Cells for further information on ap proved installation and use of this product Warning ElEctrical Hazard Do not disconnect under load Q SMart UF l 100 PrOdUct Field wiring Copper...

Страница 5: ...yourself to the national regulations for work safety and accident prevention Wear suitable protective clothing e g safety shoes protective gloves in order to prevent injuries Protect the modules again...

Страница 6: ...s Solar modules are not explosion proof operating equipment The modules are not suitable for mobile usage or for indoor installations Optimal solar irradiation results in a maximum energy yield For th...

Страница 7: ...ools mounting materials or solar modules can fall and injure people Block off the danger area on the ground before begin ning the assembly work Warn people near the danger area or in the building Keep...

Страница 8: ...ules may be installed in landscape or portrait format Install the module in such a way that the junction box is positioned in the upper area of the module and the wires hang downwards Ensure that the...

Страница 9: ...ted as a coordinated unit To ensure a long term stability of the solar modules Install the module according to the mounting variants and the defined clamp areas Please refer to the Q CELLS clamp list...

Страница 10: ...s edge to the first active cell is 18 5 mm Figure 3 Ensure that clamps overlap the glass edge Figure 3 10 mm to 15 mm on the top side of the module 12 16 mm on the module back side These specification...

Страница 11: ...mm Clamp height corresponding to 36 mm frame height Figure 4 Clamp depth 7 12 mm Figure 4 Clamp area clamp depth x clamp width 600 mm Clamps that comply to the local statics requirements Clamps that...

Страница 12: ...to account all working conditions and relevant technical regu lations and standards In this way you ensure that the maximum system voltage including the necessary safety supplements are not exceeded A...

Страница 13: ...commendations for Countries with Grounding Requirements apply Exception installation within 500 m of coastline The grounding recommen dations for Countries with Grounding Requirements apply COUNTRIES...

Страница 14: ...mum voltage system or b ground fault currents 50 mA don t exceed a length of time of 0 4 s are detectable and preventable with certainty A simple ground fault safety device must not be used Specificat...

Страница 15: ...lar cables and insulated compatible connectors Q SMART modules uses MC4 connectors Only use additional components which are compatible with the modules and its electrical specifications Ensure that al...

Страница 16: ...water from the module Do not use abrasive detergents or surface active agents e g soap Do not scratch dirt off This can damage the surface of the module Modules must not be covered by snow or ice for...

Страница 17: ...allee 17 21 06766 Bitterfeld Wolfen Germany TEL 49 0 3494 66 99 0 FAX 49 0 3494 66 99 199 EMAIL service q cells com WEB www q cells com Subject to change Q Cells SE Installation and operation manual C...

Отзывы: