7. QUICK REFERENCE FOR FAULTS
Here is a quick troubleshooting guide to any faults that you may come across.
Possible Faults
¾
THE SIREN IS ONLY SOUNDING FOR 5 SECONDS
o
The Decibell is in test mode (see ‘Testing the Piezo’s, page 6)
¾
THE SIREN AND STROBE IS NOT TRIGGERING AT ALL
o
Check the trigger selection is in the right position (see DIP switch 7 – Bell, page 7)
¾
SIREN WILL NOT TRIGGER EVEN THOUGH TRIGGERED IN TEST MODE
o
Check the voltage between B+ and B-. You should have 13V
o
Check the tamper switch is closed.
o
Check the BA voltage has returned to normal.
¾
TAMPER
o
Check the case is secure and the tamper switch connects.
o
Ensure the B- or B+ to TF (tamper loop) is in place for all Pyronix panels.
o
Check the correct Terminal Connections