DECIBELL
Page: 6 RINS040-5
Timers
DIP switch 1
DIP switch 2
DIP switch 3
DIP switch 4
2 mins
ON OFF OFF OFF
3 mins
OFF ON OFF OFF
5 mins
OFF OFF ON OFF
DO NOT USE
ON
OFF
ON
OFF
8 mins
OFF ON ON OFF
10 mins
OFF OFF OFF ON
12 MINS
ON
OFF
OFF
ON
13 mins
OFF ON OFF ON
15 mins
OFF OFF ON ON
17 MINS
OFF
ON
OFF
OFF
18 mins
OFF ON ON ON
20 mins
ON ON ON ON
Testing the Piezos
For the 5 second test feature for the PIEZO’s – (i.e. the sounders will activate for 5 seconds only), the
configuration must be as follows:
Timers
DIP switch 1
DIP switch 2
DIP switch 3
DIP switch 4
5 secs test
OFF
OFF
OFF
OFF
With this scenario, the Decibell will only sound for 5 seconds on an alarm system
regardless what the control panel bell time is programmed as.
DIP Switch 5 – LEDs
DIP Switch 5 selects how the LEDS will operate, whether they will flash alternatively, or be
illuminated all the time.
FLASHING LEDS
LED ON CONSTANTLY
FLASH
LED ON
FLASH
LED ON