8. TECHNICAL SPECIFICATIONS 

OPERATING VOLTAGE 

SIREN AND STROBE OUTPUT 

10 – 16Vdc. (13.8V Nominal) 

Maximum peak:

 

118dBA @ 1m (85dBA Spain)

 

Reverse polarity protected 

Flash rate:

 

120/min typical

 

 

Tube size:

 

3 Watt

 

CURRENT CONSUMPTION 

 

Stand by (alt. flashing):

 

30mA typical

  

 

                            

(+10mA for backup battery) BACKUP BATTERY 

Strobe only:

 

165mA typical

 

280mAh 7.2 V NiCad (included) 

Siren only:

 

245mA typical

 

30 min continuous use (Siren and Strobe) 

Siren and Strobe:

 

440mA typical

 

 

 

SIREN CUT OFF TIMER 

 

Test:

 

 5 seconds

 

DIMENSIONS & WEIGHT 

Normal: 

 15 minutes

 

Dimensions:  

325mm x 180mm x 75mm

 

 

Weight: 

1.4kg

 

ENVIRONMENT 

 

Operating Temperature:

  

-30

˚

 to 50

˚

C (-22

˚

 to 122

˚

F)

 

 

Storage Temperature: 
 

-40

˚

 to 60

˚

C (-40

˚

 to 140

˚

F)

 

 

TAMPER PROTECTION 

Activation from front or back and power supply cut off 
 

INPUT ACTUATION 

Strobe and Siren, switched negative or positive 
 
 
 
 

This product is suitable for use in systems designed to 

comply with PD 6662:2004 at Security Grade 3 and Environmental Class 4.

EN50131-1

Security Grade 3
Env

4

 

 

Содержание DECIBELL

Страница 1: ...DECIBELL Installation Instructions RINS040 5 EN50131 1 Security Grade 3 Env 4...

Страница 2: ......

Страница 3: ...7 DIP Switch 8 Sound 8 2 4 Battery Terminals 8 2 5 Strobe Connector 9 2 6 Case Tamper 9 2 7 LED Connector 10 2 8 Terminal Connections 10 3 WIRING BELL TAMPER TO CONTROL PANEL ZONES 11 4 STEPS TO INST...

Страница 4: ...u can redeem against vouchers for Argos Marks and Spencer and Dunnes ROI only 35 Points is equal to a 1 voucher Dedicated Website You will have access to a dedicated PI Club section of the Pyronix web...

Страница 5: ...upply connected will go into deep discharge and may not recover SHOCK Mount the sounder away from the public especially in enclosed areas such as alleyways and corridors in order to reduce any shock h...

Страница 6: ...t board looks like the following Figure 1 FLASH LED ON ON OFF 2 3 5 10 STB STB BELL BELL SND SND B 1 2 3 4 5 6 7 8 2 5 Strobe Connector 2 1 PIEZO Connector 2 6 Case Tamper 2 2 Rear Tamper 2 1 PIEZO Co...

Страница 7: ...on page 4 2 2 Rear Tamper The DECIBELL is fitted with a rear tamper switch operated by removing the DECIBELL from the wall The tamper switch can be adjusted by carefully bending the metal spring TAMP...

Страница 8: ...Piezos For the 5 second test feature for the PIEZO s i e the sounders will activate for 5 seconds only the configuration must be as follows Timers DIP switch 1 DIP switch 2 DIP switch 3 DIP switch 4...

Страница 9: ...sociated with the STB terminal STROBE TRIGGER STB Negative STROBE TRIGGER STB Positive STB STB STB STB 0V 0V 12V 12V DIP Switch 7 Bell DIP Switch 7 changes the polarity of the Bell Trigger this is ass...

Страница 10: ...PIEZO s SOUND A SOUND B SND SND B SND SND B 2 4 Battery Terminals The DECIBELL comes complete with a backup battery 7 2V NICAD Battery so that even in the event of a intruder sabotage the bell box wi...

Страница 11: ...K DO NOT TOUCH WARNING WHEN WORKING IN CLOSE PROXIMITY IN SUBDUED LIGHT OR DARKNESS THE STRONG LIGHT EMITTED MAY CAUSE TEMPORARY VISION FAILURE TAKE PRECAUTIONS 2 6 Case Tamper The DECIBELL is fitted...

Страница 12: ...preferred that these are disabled simply disconnect the harness from the connector or you can choose to have the LED illuminated all the time see page 6 2 8 Terminal Connections The Terminal Connectio...

Страница 13: ...the DECIBELL as the below diagram Please note that the resistance value will change depending on the alarm panel please refer to the installation manual of that alarm system NO1 C1 NO1 PGM2 PGM3 PGM4...

Страница 14: ...robe The first step is to install the strobe cover on to the front casing 4 2 Choosing the Right Surface The DECIBELL should be mounted on a flat surface in a high visibility area If the DECIBELL isn...

Страница 15: ...L RINS040 5 Page 13 Also make sure the environment is suitable The cables to the DECIBELL should be routed away from the mains supply and telephone cables to avoid any electrical interference 230V 230...

Страница 16: ...LL packaging Use the template to mark the position of the four mounting holes and the cable hole Use a suitable drill to drill the mounting holes Insert the wall plugs provided and screw the top left...

Страница 17: ...B S D C D A Menvier BELL TRIG STB HOLD OFF TAMPER RETURN HOLD OFF BELL 12V Aritech EXT BELL STROBE HO 270R TR BHO BELL 12v Gardiner Technology BELL STB SCBA SCBP SCBA BELL ADE Range B STROBE A T A D P...

Страница 18: ...DECIBELL Page 16 RINS040 5 6 WIRING TWO DECIBELLS IN SERIES PCX Range Decibell 1 SAB Decibell 2 SAB Terminal Block...

Страница 19: ...T TRIGGERING AT ALL o Check the trigger selection is in the right position see DIP switch 7 Bell page 7 SIREN WILL NOT TRIGGER EVEN THOUGH TRIGGERED IN TEST MODE o Check the voltage between B and B Yo...

Страница 20: ...typical 30 min continuous use Siren and Strobe Siren and Strobe 440mA typical SIREN CUT OFF TIMER Test 5 seconds DIMENSIONS WEIGHT Normal 15 minutes Dimensions 325mm x 180mm x 75mm Weight 1 4kg ENVIRO...

Страница 21: ...DECIBELL RINS040 5 Page 19...

Страница 22: ......

Страница 23: ......

Страница 24: ...6 8QY UK Customer Support 44 0 845 6434 999 local rate or 44 0 1709 535225 Hours Mon to Fri 8 00am till 6 30pm Email customer support pyronix com Website www pyronix com This product is approved for u...

Отзывы: