3. WIRING BELL TAMPER TO CONTROL PANEL ZONES
The examples below show how to connect the bell tamper to the Matrix 6 / 816 systems, this system
uses a zone as a tamper circuit.
If the alarm panel requires
end of line resistors
, wire the DECIBELL as the below diagram.
Please note that the resistance value will change depending on the alarm panel (please refer to the
installation manual of that alarm system).
NO1
C1
NO1 PGM2 PGM3 PGM4 PGM5 PGM6
+ AUX -
K+
KD
K-
Z1
COM
Z2
Z3
COM
Z4
+ AUX -
Z5
COM
Z6
Matrix 6 / 816
If the alarm panel is wired normally closed, wire the DECIBELL as the following:
NO1
C1
NO1 PGM2 PGM3 PGM4 PGM5 PGM6
+ AUX -
K+
KD
K-
Z1
COM
Z2
Z3
COM
Z4
+ AUX -
Z5
COM
Z6
Matrix 6 / 816
EOL
Resistor