2.1 PIEZO Connector
The DECIBELL incorporates 2 x PIEZOs that connect to the PCB. These can be disconnected while
installing the system so that the loud noise will not be a distraction, or you can use the test feature –
please see page 6. The connectors are shown in Figure 1 on page 4.
2.2 Rear Tamper
The DECIBELL is fitted with a rear tamper switch, operated by removing the DECIBELL from the
wall.
The tamper switch can be adjusted by carefully bending the metal spring.
TAMP
FEED
TAMP
FEED
TAMP
RET
TAMP
RET
(BT)
(BT)
Cli
ck
2.3 Dip Switches
FLASH
LED ON
ON
OFF
2
3
5
10
STB-
STB+
BELL-
BELL+
SND
SND B
1
2
3
4
5
6
7
8
DIP Switches 1, 2, 3 and 4
DIP switches 1, 2, 3 and 4 are used to select the timers for the Decibell sounders.