Installation and Setup
Before you operate the workcell, know the components. Do the steps in this manual for
safe and correct operation.
Warning: Only qualified personnel should do these procedures. Obey this manual and
all applicable safety regulations. A “qualified person” is defined as “a person or
persons who, by possession of a recognized degree, certificate, or professional
training, or who, by extensive knowledge, training, and experience, has successfully
demonstrated the ability to solve problems relating to the subject matter and work.”
(Ref. ANSI/ASME B30.2-1983.)
Uncrate and Inspect
1.
Use the Utility knife to cut the straps and the shrink wrap.
2.
Remove the cardboard as well as all packing materials and straps.
3.
Use a 9/16” wrench to remove the shipping bracket from the crate. Use a 3 mm hex
key to remove the four shipping brackets. There are two on each side of the
machine.
To Place the Dispense System
1.
Move the workcell to the necessary location.
2.
Loosen the lock nuts on each foot of the workcell, if necessary.
3.
Make sure that all four (feet) touch the ground. If any feet do not touch the ground,
use the adjustable wrench to lower the feet by turning the feet clockwise.
Figure 1: Adjust the Feet
NOTE: When you lower the feet, you raise the workcell. When you raise the feet, you
lower the workcell.