Reverse Polarity Light Test Switch
There is a momentary switch located below the reverse polarity light in the AC breaker panel. This switch
is used to test the reverse polarity light to ensure that it is functioning. The light can be tested by depressing
the switch whenever the AC system is activated. The reverse polarity light should be tested each time the AC
system is activated. If the light does not activate when the switch is pressed, disconnect the shore power cable
and notify a qualified electrician to check the light and the dockside wiring if necessary.
Microwave
Supplies AC current directly to the microwave oven. See the microwave manual for more information.
Water Heater
Supplies electrical current directly to the water heater circuit. The water temperature is automatically
controlled by a thermostat in the water heater control panel. Before operation, you must have water in the
water heater (see the water heater manual for more information).
Battery Charger
The battery charger supplies electrical current directly to the automatic battery charger. The battery charger
charges and maintains the 12-volt batteries simultaneously when activated. It is automatic and is equipped
with an amp meter to monitor charging. See the battery charger manual for more information.
Battery Charger Operation:
At dockside, when the boat is connected to shore power, the battery charger maintains the charge on the house
and engine batteries. When operating on the optional generator, the on-board battery charger must be on to
maintain charge on the house battery. The generator charging system does not generate enough current to keep
up with the electrical demand on the house battery.
The wires that supply DC charging current to the batteries are protected by an internal fuse in the battery
charger and three circuit breakers, one for each battery bank output wire. The external breakers protect the
DC charging circuit from the batteries to the charger. They are located on the DC distribution panel. Push
to reset the breakers. The internal fuses in the charger protect the DC charging circuit from the charger to the
batteries. The battery charger is located in the cockpit machinery space.
Air Conditioner (Optional)
Supplies electrical current to the air conditioning control panel and the air conditioner raw water pump when
this option is installed. Otherwise it is reserved for additional AC equipment. This breaker will trip if sea
water is not being supplied to the air conditioning unit. If this breaker trips, reset and check for water flow
out of the air conditioning thru-hull. Refer to the air conditioner owner’s manual for additional information.
Island and Interior Outlets
Supply electrical current to the cabin ground fault interrupter (GFI) electrical outlets. All AC electrical outlets
are provided with ground fault interrupters to protect against electric shock. These outlets should be tested
periodically to ensure proper operation by pressing the test/reset buttons in the center of face plate. GFI outlets
do not protect against short circuits and overloads. This is done by the outlet breakers on the AC panel.
GFI OUTLETS DO NOT PROVIDE 100% PROTECTION FROM ELECTRIC SHOCK. EVEN
THOUGH GROUND FAULT INTERRUPTERS PROVIDE PROTECTION BY REDUCING EX-
POSURE TIME FROM LINE TO GROUND SHOCK HAZARDS, IT IS STILL POSSIBLE TO
RECEIVE AN ELECTRIC SHOCK FROM DEFECTIVE APPLIANCES OR POWER TOOLS AND
MISUSED ELECTRICAL EQUIPMENT.
Содержание 3480 Drummond Runner
Страница 2: ...3480 DRUMMOND RUNNER 2 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 4: ...3480 DRUMMOND RUNNER 4 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 6: ...3480 DRUMMOND RUNNER 6 OperatorNotes...
Страница 8: ...3480 DRUMMOND RUNNER 8 OperatorNotes...
Страница 10: ...3480 DRUMMOND RUNNER 10 OperatorNotes...
Страница 26: ...3480 DRUMMOND RUNNER 26 OperatorNotes...
Страница 32: ...3480 DRUMMOND RUNNER 32 OperatorNotes...
Страница 52: ...3480 DRUMMOND RUNNER 52 OperatorNotes...
Страница 56: ...3480 DRUMMOND RUNNER 56 OperatorNotes...
Страница 76: ...3480 DRUMMOND RUNNER 76 OperatorNotes...
Страница 92: ...3480 DRUMMOND RUNNER 92 OperatorNotes...
Страница 100: ...3480 DRUMMOND RUNNER 100 OperatorNotes...
Страница 108: ...3480 DRUMMOND RUNNER 108 OperatorNotes...
Страница 116: ...3480 DRUMMOND RUNNER 116 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 118: ...3480 DRUMMOND RUNNER 118 Hours Date Dealer Service Repairs MAINTENANCE LOG...
Страница 119: ...3480 DRUMMOND RUNNER 119 Hours Date Dealer Service Repairs MAINTENANCE LOG...
Страница 120: ...3480 DRUMMOND RUNNER 120 Hours Date Dealer Service Repairs MAINTENANCE LOG...
Страница 121: ...3480 DRUMMOND RUNNER 121 Hours Date Dealer Service Repairs MAINTENANCE LOG...
Страница 122: ...3480 DRUMMOND RUNNER 122 Hours Date Dealer Service Repairs MAINTENANCE LOG...
Страница 126: ...3480 DRUMMOND RUNNER 126 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 130: ...3480 DRUMMOND RUNNER 130 THIS PAGE WAS LEFT BLANK INTENTIONALLY...