DO NOT ATTEMPT TO CORRECT THE WIRING YOURSELF. ELECTRIC SHOCK CAN
CAUSE SEVERE INJURY OR EVEN DEATH. ALWAYS HAVE A QUALIFIED ELECTRICIAN
CHECK WIRING.
KEEP CHILDREN AWAY FROM ANY ELECTRICAL CABLES OR EQUIPMENT AND AL-
WAYS USE GROUNDED APPLIANCES ON BOARD YOUR BOAT.
DO NOT OPERATE THE AC ELECTRICAL SYSTEM FROM SHORE POWER WITH RE-
VERSE POLARITY. REVERSE POLARITY WILL DAMAGE THE SYSTEM AND EXPOSE
PASSENGERS TO ELECTROCUTION HAZARDS. THIS CONDITION COULD ALSO CAUSE
A FIRE IN THE ELECTRICAL SYSTEM.
DISCONNECTING PROCEDURE FOR SHORE POWER CONNECTION
Turn the main breaker on the AC panel and the disconnect switch on the dockside outlet to the “OFF” position.
Disconnect the cable from the dockside outlet and replace the outlet caps. Disconnect the cable from the boat
and close the inlet cap. Store cable.
AC BREAKER PANEL
The AC panel is located in the cabin. The following are descriptions
of the AC panel equipment and the breakers that protect the
accessories:
AC Amp Meter
Indicates the total amperage or current being drawn through the AC
panel. It is the total current level of all of the AC equipment in
operation at the time.
AC Volt Meter
Indicates the voltage supplied to the panel.
AC Main Breaker
Protects the general distribution network. This breaker is very sensitive. The resulting power surge that occurs
when connecting the dockside cord may cause the main breaker to trip. To avoid this surge, always turn the
main breaker to the “OFF” position before plugging or unplugging the shore power cord. The AC
panel also is equipped with a relay that will cause the main breaker to trip when reverse polarity current is
detected.
Reverse Polarity Light
The red light indicates reverse polarity current supplied to the panel. This situation will cause the red light
to remain lit. Additionally, a special relay attached to the main breaker will automatically turn the main
breaker off whenever reverse polarity is achieved. If reverse polarity is achieved, immediately turn off all
cabin AC breakers and dockside outlet breakers. Disconnect the power cable from the dockside outlet and
notify a qualified electrician to check the dockside wiring.
AC Breaker Panel
Содержание 3480 Drummond Runner
Страница 2: ...3480 DRUMMOND RUNNER 2 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 4: ...3480 DRUMMOND RUNNER 4 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 6: ...3480 DRUMMOND RUNNER 6 OperatorNotes...
Страница 8: ...3480 DRUMMOND RUNNER 8 OperatorNotes...
Страница 10: ...3480 DRUMMOND RUNNER 10 OperatorNotes...
Страница 26: ...3480 DRUMMOND RUNNER 26 OperatorNotes...
Страница 32: ...3480 DRUMMOND RUNNER 32 OperatorNotes...
Страница 52: ...3480 DRUMMOND RUNNER 52 OperatorNotes...
Страница 56: ...3480 DRUMMOND RUNNER 56 OperatorNotes...
Страница 76: ...3480 DRUMMOND RUNNER 76 OperatorNotes...
Страница 92: ...3480 DRUMMOND RUNNER 92 OperatorNotes...
Страница 100: ...3480 DRUMMOND RUNNER 100 OperatorNotes...
Страница 108: ...3480 DRUMMOND RUNNER 108 OperatorNotes...
Страница 116: ...3480 DRUMMOND RUNNER 116 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 118: ...3480 DRUMMOND RUNNER 118 Hours Date Dealer Service Repairs MAINTENANCE LOG...
Страница 119: ...3480 DRUMMOND RUNNER 119 Hours Date Dealer Service Repairs MAINTENANCE LOG...
Страница 120: ...3480 DRUMMOND RUNNER 120 Hours Date Dealer Service Repairs MAINTENANCE LOG...
Страница 121: ...3480 DRUMMOND RUNNER 121 Hours Date Dealer Service Repairs MAINTENANCE LOG...
Страница 122: ...3480 DRUMMOND RUNNER 122 Hours Date Dealer Service Repairs MAINTENANCE LOG...
Страница 126: ...3480 DRUMMOND RUNNER 126 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 130: ...3480 DRUMMOND RUNNER 130 THIS PAGE WAS LEFT BLANK INTENTIONALLY...