User Manual
PT-PMS-42S
48
Command
Function
Command Example
#SET_ON_[PARAM1]_[
PARAM2]_[PARAM3]:X
XXX
When power on system, automatically send the
ASCII or HEX command to the third-party device.
[PARAM1]=A/H: Represents the command
format.
[PARAM1]
Command Format
A
ASCII
H
HEX
[PARAM2]=01~02: Represents the RS232
port.
[PARAM2]
RS232 Port
01
The RS232 port of the
switcher.
02
The RS232 port of the
far-end HDBaseT
receiver.
[PARAM3]=01~07: Represents the baud rate
of third-party device.
[PARAM3]
Baud Rate
01
2400
02
4800
03
9600
04
19200
05
38400
06
57600
07
115200
XXXX: ASCII or HEX characters.
#SET_OF_A_01_03:123
456789
Explanation:
Automatically send the
ASCII command
“123456789” to the
third-party device
which is connected to
the RS232 port of
switcher. The baud rate
of third-party device is
9600.
#SET_OF_H_02_03:30
31 32 33 34
Explanation:
Automatically send the
HEX command “30 31
32 33 34” to the
third-party device
which is connected to
the RS232 port of
receiver. The baud rate
of third-party device is
9600.